Use unions at pipe connections to 

enable easy removal and servicing. 

Use sufficient tape to ensure airtight 

seal and hand tighten only. To prevent 

strain on pump threads always support 

heavy inlet and outlet pipes. If there 

is a likelihood the water supply may 

contain solid particles such as pieces of 

plant or vegetable matter, a filter should 

be installed before the pump to avoid 

blocking of water ways. Lay suction pipe 

at a constant gradient to avoid air pockets 

which may reduce pump efficiency.

NOTE: Suction leaks are the largest cause of poor pump performance and 

are difficult to detect. Ensure all connections are completely sealed using 

thread tape only. 

Flexible pipe should be considered to allow for movement between 

building, pump and/or water supply. Braided hose, reinforced hose or 

polythene pipe are suitable.

Do not use pipe thread sealing compounds on any part of this pump. ONLY 

use Teflon sealing tape.

Pipe Connections

For best performance use 

P.V.C. or polythene pipes at 

least the same diameter as the 

pump’s inlet and delivery outlet 

openings. Larger diameter 

pipe may be used to minimise 

resistance to flow when pumping 

longer distances.

NOTE: For protection, the Davey pump motors are fitted with an automatic 

reset thermal overload, constant tripping of this overload indicates a 

problem e.g. low voltage at pump, excessive temperature (above 115°F) in 

pump enclosure.

Extra Draw-off Capacity

The Torrium2 controller has an in-built accumulator which will accommodate small 

leaks. In some applications it may be appropriate to install additional accumulator 

(Supercell pressure tank) capacity. These applications includes:

•   Long suction lines (see Suction Lines / Lift)

•   Low flow appliances connected to the pump, such as evaporative air 

conditioners, slow filling toilet cisterns, etc.

Any additional accumulators can be installed downstream of the controller (ie. 

between the controller and the first outlet).
Where extra draw-off capacity is utilised the additional pressure tank should have a 

pre-charge of 70% of the maximum system (shut-off) pressure, see table below.

Содержание BT14-300

Страница 1: ...pework be disassembled unless the internal pressure of the unit has been relieved Failure to observe this warning will expose persons to the possibility of personal injury and may also result in damage to the pump pipework or other property WARNING Failure to follow these instructions and comply with all applicable codes may cause serious bodily injury and or property damage NOTE Prior to installa...

Страница 2: ...tc 2 Provides automatic cut out protection should the pump run out of water or overheat should the pump fail to start due to low voltage or a blockage in the pump 3 Provides an easy to understand visual representation of the system status 4 Has adaptive pressure cut in which allows the pump to start at approximately 80 of the maximum pressure at last shut down This allows the controller to accommo...

Страница 3: ...he controller adaptor nut is able to rotate independent of the Torrium2 and the complete pump this allows it to be tightened onto the pump easily For ease of installation a tightening tool is included with Torrium2 to tighten the controller nut to ensure a firm connection to your controller The ability to rotate the adaptor nut also means that the complete controller once fitted to the pump can be...

Страница 4: ... be horizontally mounted on a firm base allowing for drainage to avoid damage to flooring etc that over time may occur from leaking pipe joints or pump seals Do not mount the pump vertically Never place flammable materials on or near your pump WARNING Some insects such as small ants find electrical devices attractive for various reasons If your pump enclosure is susceptible to insect infestation y...

Страница 5: ...lightning or a very powerful surge hits the pump unit If the installation is subject to electrical power surges or lightning we strongly recommend the use of suitable additional surge protection devices on ALL electrical equipment Always disconnect and lockout all electrical power when installing or working on pumps motor or switches Insure the power supply breaker is off or the disconnect where u...

Страница 6: ...ons For best performance use P V C or polythene pipes at least the same diameter as the pump s inlet and delivery outlet openings Larger diameter pipe may be used to minimise resistance to flow when pumping longer distances NOTE For protection the Davey pump motors are fitted with an automatic reset thermal overload constant tripping of this overload indicates a problem e g low voltage at pump exc...

Страница 7: ...some suction lift installations there may be good reason to modify the inbuilt check valve to ensure that the discharge pressure is also applied to the suction line and footvalve This could be where the suction line was very long or where there was concern regarding a leaking footvalve This may not always be applicable and it is acceptable to retain the inbuilt check valve in the Torrium2 on sucti...

Страница 8: ...lations 8 Models Maximum Inlet Pressure BT14 300 60 psi BT30 30 BT20 30 50 psi BT14 45 40 psi BT20 40 20 psi NOTE The above pressure limits also apply to well pump boosting Connection to your Water Source FLOODED SUCTION FROM CISTERN OR STORAGE TANK Installations with flooded suction require a gate valve so water supply can be turned off for pump removal and servicing FLOODED SUCTION FROM MUNICIPA...

Страница 9: ... home pressures and in those cases the pressure reducing valve will need to be set to lower pressures Note The maximum System Pressure should not exceed 100psi Local code limits for home pressure Pressure reducing valve setting psi BT14 30 BT20 30 BT14 45 BT20 40 BT30 30 No limit 60psi 50psi 40psi 20psi 50psi 80psi 40psi 30psi 30psi N A 30psi 70psi 30psi 20psi 20psi N A 20psi The chart above shows...

Страница 10: ... water demand Priming and Operation The Torrium2 module fitted to your BT Booster is provided with a push button Prime button This button is used during initial priming of the pump and also acts as a reset button if the Torrium2 switches out in pump protection mode 1 Remove priming plug and fill casing and suction line on flooded suction or mains boosting simply open gate valve to pump When full r...

Страница 11: ...Consult Davey dealer 2 Motor not free to turn e g a jammed impeller Consult Davey dealer 3 Prime button has been held in for too long Release prime button and switch off power for 1 minute to allow unit to reset 4 Your Torrium2 has detected high water temperature in the pump Once the water has cooled the Torrium2 will automatically restart the pump e PUMP WILL NOT STOP 1 Water leaks on discharge s...

Страница 12: ...ring servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING Do not use hydrocarbon based or hydrocarbon propelled sprays around the electrical components of this pump This pump is not to be used by children or infirm persons and must not be used as a toy by children WARNING When servicing or attending pump always ensu...

Страница 13: ...NOTES 13 ...

Страница 14: ...13 NOTES ...

Страница 15: ... Customer Service line on 1300 367 866 in Australia or 0800 654 333 in New Zealand send a written letter to Davey at the address listed above or email sales davey com au 2 Any warranty claim must be accompanied by proof of purchase and details of the alleged defect 3 On receipt of your claim Davey will seek to resolve your difficulties or if the product is faulty or defective advise you on how to ...

Страница 16: ...eyusa com AUSTRALIA Head Office 6 Lakeview Drive Scoresby Australia 3179 Ph 613 9730 9124 Fax 613 9753 4248 Email export davey com au Website davey com au NEW ZEALAND 7 Rockridge Avenue Penrose Auckland 1061 Ph 0800 654 333 Fax 0800 654 334 Email sales dwp co nz Website daveynz co nz EUROPE ZAC des Gaulnes 355 Avenue Henri Schneider 69330 Meyzieu France Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 ...

Отзывы: