Lamp Installation

Once the Steriflo

®

Treatment Chamber has been connected to the pipework, the

installation should be checked for water leaks. For installations using a pressure

pump, connect 3-pin plug to main power socket, prime the pump and fill chamber

with water.

Once checked, disconnect power to the pump and remove 3-pin plug from

socket.

Attach the “DO NOT LOOK AT LAMP” sticker in an obvious position on the

treatment chamber, check that the chamber is clean to ensure the sticker will

adhere correctly.
The Quartz Sleeve is pre-installed in the treatment chamber, and provided the

endcap has not been disturbed or undone, is able to withstand well in excess of

the maximum operating pressures.
If the chamber test is successful, it is now time to insert the lamp.
Expose the connection end of the lamp from its transport tube and protective

wrapping. The lamp connection socket is “keyed” to ensure correct alignment.

Carefully remove the tube fully from its transport tube, touching the lamp as little as

possible. Handle the lamp by the ends where possible. Wipe with clean cloth and

methylated spirits if fingerprints or dirt need removing. Slide the lamp into the

chamber, fit lamp connection socket and then fasten the end washer into the

endcap, with the screws provided.

Operation

Once all leak testing and lamp fitment has been completed, prime pump and

connect pump lead to supplied outlet. Connect three pin plug to power outlet and

switch on. Open valves and allow water to fill the chamber. The “Mains On”

Amber LED will be illuminated and the red alarm light will flash slowly. Note: If

chamber does not fill with water within two minutes, reprime the pump to avoid

damage to the lamp.
Allow two minutes for the UV lamp to reach full intensity before starting water flow.

Full lamp performance for a new installation will be achieved in 24 hours. On a

new installation where no other form of sterilisation has been in constant usage,

we recommend flushing the pipework with a suitable sanitiser such as Steritank HP

or Davey Acquasafe - for dosage refer to product instructions. This solution should

be left in the piping for at least an hour and preferably overnight.

The sanitising solution can be dosed to the water tank or if necessary added as a

shot dose to the bowl of any filter housing installed with the UV system and slowly

flushed into the piping.

If dosed to the water tank the Steritank HP or Davey Acquasafe can be left in the

water as it is tasteless and suitable for use in drinking water. If added as a shot

dose it should be rinsed out through a nearby tap.

Davey Water Products can not accept responsibility for loss or damage

resulting from incorrect or unauthorised installations.

Содержание Steriflo UV50

Страница 1: ...Maximum operating pressure for stainless steel UV chambers is 860kPa 125 psi If this pressure can be exceeded or if operating close to this pressure fit a suitable pressure limiting valve in the supply to the UV chamber If any electrical supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not i...

Страница 2: ...on Page 5 Electrical Power Surge Protection Page 5 6 Pipe Connections Page 6 Pre treatment drinking water Page 6 Lamp Installation Page 7 Operation Page 7 Maintenance Page 8 9 Water Quality Page 9 Lamp Fail Alarm Page 9 Trouble Shooting Page 10 Specifications Page 10 Spare Parts Page 10 Warning UV Radiation Page 11 After Sales Service Page 11 ...

Страница 3: ...uctions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Ultra Violet water treatment system is designed to handle clean water free of particulate matter The system should not be used for any other purpose without specific referral to Davey Water Products The use of the system with flammable corrosive and other materials of a hazardous natur...

Страница 4: ...uring servicing Leave a chamber lengths space at the lamp connector end for lamp removal Installation can be horizontal outlet facing upwards or vertical outlet horizontal Housing your Steriflo System To protect your Steriflo system from the weather make sure the site is water proof frost free and has adequate ventilation Allow for drainage to avoid damage to flooring etc that over time may occur ...

Страница 5: ... only work when unit is connected to the correct electrical supply Install the power supply enclosure above the treatment chamber so that in the event of a leak water cannot drip down the lamp lead into the enclosure CAUTION The supply cord is necessary for lamp changing The three pin supply plug must remain accessible after installation If installed to fixed wiring without the plug a two pole swi...

Страница 6: ...lows If flows may exceed the design maximum install a flow restriction device Use unions at pipe connections to enable easy removal and servicing Use sufficient tape to ensure airtight seal and do not over tighten To prevent strain on unit threads always support heavy inlet and outlet pipes Pre treatment drinking water Prefiltration is usually required to ensure that particulate matter does not sh...

Страница 7: ...ith the screws provided Operation Once all leak testing and lamp fitment has been completed prime pump and connect pump lead to supplied outlet Connect three pin plug to power outlet and switch on Open valves and allow water to fill the chamber The Mains On Amber LED will be illuminated and the red alarm light will flash slowly Note If chamber does not fill with water within two minutes reprime th...

Страница 8: ...ir the UV output The quartz sleeve should be removed after one month and inspected for deposits Clean with methylated spirits 5 hydrochloric acid if heavily fouled and carefully dry Handle the sleeve with tissue to keep it clean The sleeve should be cleaned every three months or as required Sleeve removal use care fragile 1 Remove lamp as described 2 Remove drain port cap and empty water from cham...

Страница 9: ...replaced as required to maintain them in good condition UV transmissibility UVT of the water can be tested by your local dealer or by undertaking an appropriate water test Lamp Alarm System If the UV lamp is out due to a failure or bad connection the alarm buzzer will sound and the flashing red LED will light continuously The alarm will disconnect power to the pump lead preventing untreated water ...

Страница 10: ... short in lamp circuit Specifications Flow range UV50 0 50 l min Flow range UV70 0 70 l min Water temperature range 8 35o C Water pressure 0 860 kPa Operating voltage frequency 220 240v 50Hz Power consumption 45 W Lamp life 9 000 hours 1 year s running Spare Parts Lamp GPH550N2W Sleeve TT600 End nut S333A Cover plate S334A Lamp connector and lead S486 Oring S24x3N70 White pressure ring S113 WARNIN...

Страница 11: ...l hours later Severe exposure sore red eyes sensitive to light painful to keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attention SKIN In mild cases removal fro...

Страница 12: ...islation of the various Australian states or the Consumers Guarantee Act 1993 NZ Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from the product or any defect 7 Where the Trade Practices Act Aust the Goods and Consumer Protection Legislation of the various Australian states and t...

Отзывы: