22
CLEANING THE CELL
1. Turn off Power to unit and isolate & drain by-pass line
2. Drain water from cell with drain valve
3. Remove union at top of cell and inspect cell using flashlight
4. If build up is present,
(do not use pressure wash).
Mix a solution consisting of 20% Muriatic
Acid and water.
Muriatic acid is co rrosive. Please follow safety instructions and wear protective clothing.
NEVER add water-to-acid. ALWAYS add acid-to-water.
With lower drain valve closed, add this solution
to top of c ell and wait 15 to 20 mins before draining .
Note, allowing cell to sit in this
solution for longer than 15 – 20 mins may damage the cell and/or reduce cell life
.
5. Drain and dispose of the liquid in an environmental manner
TROUBLE SHOOTING
Little or no maintenance should be required for your ECO-matic Commercial System. Its operation should be checked at
least daily or whenever the operator is in the pump house or near the unit.
Of particular importance is the small fan
under the Power Supply
. If it is found in a failed state the unit should be tuned off until it is replaced. Problem checklist:
1. Power to Power Supply, but Control Box does not operate.
•
Check all leads from the Power Supply to the Control Panel.
•
Open the Power Supply and inspect the displays in the plastic enclosure in the
lower portion of the Power Supply. They should be lit. If the Control Panel is note
operating (is not lit) contact your factory/ECO-matic distributor.
•
If the LEDs are not lit, check the Power Supply fuse/breaker in the bottom of the unit. If blown, replace it and re -
connect power. If the fuse blows immediately, contact your factory/ECO-matic distributor.
2. System will not produce chlorine (keeps shutting down).
•
Check cell connections and with unit powered off, ensure that all Power Supply connections are tight
•
Check Control Panel to see which of the systems is causing the shutdown. If it is temperature related, check the
pool temperature. If it is conductivity related, check the pool salt level. Remember it can be a combination of both
temperature and
salinity that can cause the
Low Conductivity Shutdown.
3. Unit keeps shutting down when all chemical levels and temperatures are correct.
•
Cell may have failed or is badly connected. The cell has a lim ited life span of approximately 30,000 hours. This is
dependent on many factors such as salinity, other minerals in the water and water temperature.
When the cell has failed contact your ECO-matic dealer or distributor. The cell will require replacement with either a new
or reconditioned cell. Please note that it is the internal section of the cell that will be replaced, not the external housing.
4. Power Supply and Control Box Faults.
•
Should there be a problem with these components please contact your
ECO-matic dealer or distributor.
PLEASE NOTE: Always ensure that your ECO-matic System is repaired only by an authorized ECO-matic Dealer
and that only genuine ECO-matic parts are used.
TECHNICAL INFORMATION