6.1 Overall dimensions DAS 50 / DAS 50N
The size of the enclosure depends on the type of
extender used and its length.
Download 3D models from our web-site.
Dimensions refer to the 15mm extension.
5 TROUBLESHOOTING
5.1 Problems and solutions
The search for defects in the operation should be performed only by personnel qualified respecting the safety rules
in force.
6 SPARE PARTS AND DIMENSIONS
Installation and maintenance guide
PROBLEM
POSSIBLE CAUSE
SOLUTION
Nothing or little fluid
Valve does not receive the command
Check valve (solenoid valve) control. Perform
a manual test.
The pressure of the fluid is too low
or absent.
Check the fluid supply pressure and, if
necessary, increase it.
The nozzle is clogged
Unscrew and clean the nozzle.
The filter is dirty (if present)
Wash or replace the filter.
A tube is bent
Check the status of the fluid supply pipes
Insufficient drive pressure
Check drive pressure (5-7 bar)
Fluid residues present in the system
Clean the system with water
Fluid out of the compass O-ring or shaped gasket on the damaged
valve body
Replace O-ring or shaped gasket
Fluid flow between valve
body and fixing plate
O-ring on the damaged dam reservoir
Replace the O-ring of the hub
The nozzle dries even if
the valve is not piloted
Presence of dirt in the nozzle
Clean or replace the nozzle.
The valve opens late
Insufficient drive pressure
Check drive pressure 5-7 bar
O-ring on the damaged spike
Replace the O-ring on the pin
Splashed irregularly
Insufficient spraying pressure
Check spraying pressure
(0,1…2,5 bar)
Dirt in the air cap
Clean the air cap
black
air drive
transparent
material
blue
nebulization