DAV TECH DAS 50N Скачать руководство пользователя страница 6

6.1 Overall dimensions DAS 50 / DAS 50N

The size of the enclosure depends on the type of 
extender used and its length. 
Download 3D models from our web-site.
Dimensions refer to the 15mm extension.

5 TROUBLESHOOTING
5.1 Problems and solutions
The search for defects in the operation should be performed only by personnel qualified respecting the safety rules 

in force.

6 SPARE PARTS AND DIMENSIONS

Installation and maintenance guide

PROBLEM

POSSIBLE CAUSE

SOLUTION

Nothing or little fluid

Valve does not receive the command

Check valve (solenoid valve) control. Perform 

a manual test.

The pressure of the fluid is too low

or absent.

Check the fluid supply pressure and, if 

necessary, increase it.

The nozzle is clogged

Unscrew and clean the nozzle.

The filter is dirty (if present)

Wash or replace the filter.

A tube is bent

Check the status of the fluid supply pipes

Insufficient drive pressure

Check drive pressure (5-7 bar)

Fluid residues present in the system

Clean the system with water

Fluid out of the compass O-ring or shaped gasket on the damaged 

valve body

Replace O-ring or shaped gasket

Fluid flow between valve 

body and fixing plate

O-ring on the damaged dam reservoir

Replace the O-ring of the hub

The nozzle dries even if 

the valve is not piloted

Presence of dirt in the nozzle

Clean or replace the nozzle.

The valve opens late

Insufficient drive pressure

Check drive pressure 5-7 bar

O-ring on the damaged spike

Replace the O-ring on the pin

Splashed irregularly

Insufficient spraying pressure

Check spraying pressure

(0,1…2,5 bar)

Dirt in the air cap

Clean the air cap

black 

air drive

transparent 

material

blue 

nebulization

Содержание DAS 50N

Страница 1: ...PRAY VALVE FOR INTERNAL DAS 50N DAV TECH SRL Via Ravizza 30 36075 Montecchio Maggiore VI ITALY Tel 0039 0444 574510 Fax 0039 0444 574324 davtech davtech it www davtech it Installation and maintenance...

Страница 2: ...chine 3 2 Drive the valve 3 3 Fluid connection 3 4 Setting of the dispensed shot 3 5 Amount of the shot 4 MAINTENANCE pag 5 4 1 General rules 4 2 Cleaning and replacing the nozzle 4 3 Valve Disassembl...

Страница 3: ...ranty period does not extend in any way the validity period of the guarantee The seller is not liable for defects caused by normal wear of parts which by their nature are subject to wear 1 3 Goods rec...

Страница 4: ...late on the valve A good valve fixing on the machine must be guaranteed stable without vibration and with good accessibility for adjustment cleaning and maintenance 3 2 Drive the valve The DAS 50 DAS...

Страница 5: ...eaching the end of the stroke the valve will be fully closed so it will not flow fluid Rotate counterclockwise to increase the stroke and then the amount of fluid 3 5 Amount of the shot Adjusting the...

Страница 6: ...rew and clean the nozzle The filter is dirty if present Wash or replace the filter A tube is bent Check the status of the fluid supply pipes Insufficient drive pressure Check drive pressure 5 7 bar Fl...

Страница 7: ...84050206 15 1 NEEDLE BASIC 20 mm 0003 84050306 15 2 NEEDLE BASIC 30 mm 0003 84050506 15 3 NEEDLE BASIC 50 mm 0003 84051006 15 4 NEEDLE BASIC 100 mm 0003 84052006 15 5 NEEDLE BASIC 200 mm 16 0003 3600...

Страница 8: ...ithout notice the specifications dimensions and weights in this manual The illustrations are not binding DAV TECH SRL Via Ravizza 30 36075 Montecchio Maggiore VI ITALY Tel 0039 0444 574510 Fax 0039 04...

Отзывы: