3.4 Setting of the dispensed shot
Pin stroke adjustment determines the amount of fluid delivered.
> Version with micrometric adjustment:
To adjust the travel, act on the adjustment knob at the top of the valve.
Rotate clockwise to decrease the stroke and consequently the amount of adhesive.
Turning clockwise, reaching the end of the stroke the valve will be fully closed, so it will not flow fluid.
Rotate counterclockwise to increase the stroke and then the amount of fluid.
3.5 Amount of the shot
Adjusting the amount of material (fluid) is determined by:
> Fluid pressure
> Needle stroke adjustment
> Valve opening time
Acting on these factors, you can adjust the amount of material you want.
Do not tighten the needle setting too firmly to avoid damaging the needle and nozzle.
Adjustment knob