The glow plugs can now be tested accurately.
TO OPERATE
button.
itive” end of the glow plug with the tip of the red test probe.
DTK801 will take a reading every few seconds and the results are displayed on the LCD
as follow:
LCD Display
Perimeters
Indication
Beep Alarm
0.00Ω to 0.06Ω
Shorted
(cont. beep x20)
0.07Ω to 2.50Ω
OK
(no sound)
2.51Ω to 5.50Ω
High Resistance
(2 beeps x 5)
5.51Ω to 25.0 Ω
Bad Resistance
(cont. beep x20)
Open or 25.0 Ω
above
Open Circuit
(cont. beep x20)
Low Battery
warning – Cut OFF
at 2.0V