Operation
5.5 Manufacturer Parameters
The difference of the FACTORY PARAMETERS and the CUSTOMER PARAMETERS
is that the FACTORY PARAMETERS can not be modified unless you have the initial
password from the manufacturer. The modification method of the FACTORY
PARAMETER is the same as that of the CUSTOMER PARAMETER. The main functions
of the parameters are as the following table.
Parameter
Initial Value
Functions
Host rated current
MAXIMUM
OVERLOAD VAULE
OF THE MOTOR /1.2
After the starting delay time, when the motor
current is greater than 1.2 times of the set value
and less than 4 times of the set value, the unit
will jump as per overload feature.
Fan rated current
Maximum allowable
motor overload
value/1.2
Same as above
Pre-alarm T.
105
℃
Pre-alarm when the temperature reaches this set
value
Stop T.
110
℃
Alarm when the air exhausting temperature
reaches this set value.