DAT 4530
DAT 4530
Universal isolated converter
configurable by Dip-Switch or PC
double output & trip amplifier
TECHNICAL SPECIFICATIONS (Typical @ 25 °C and in nominal conditions)
Line resistance influence
(1)
TC, mV
<=0.8 uV/Ohm
RTD 3w
(50
W
max balanced)
0.05%/
W
RTD 4w
(100
W
max balanced)
0.005%/
W
Linearity
(1)
TC, RTD
± 0.1 % f.s.
mV, V, mA
± 0.05 % f.s.
Thermal drift
(1)
Full scale
± 0.01% / °C
CJC
± 0.01% / °C
RTD excitation current
RTD, Res
400 uA
CJC Comp.
± 0.5°C
Input impedance
TC, mV
>= 10 M
W
mA
~22
W
Aux. Voltage
>18V @ 20mA
ALARM TRIP (SSR)
Contact
SPST
Max Load (resistive) :
Voltage
48 Vdc / 30 Vac
Current
0.4 A
Aux. Voltage
>12V @ 20mA
FEATURES
- Universal configurable input for:
mV, Tc, RTD, Res, Potentiometer, V and mA
- Two outputs configurable in current or voltage
- Trip alarm
- Configurable by dip-switch or PC
- High accuracy
- On-field reconfigurable
- Galvanic isolation among all the ways
- UL / CE mark
- Suitable for DIN rail mounting in compliance
with EN-50022 and EN-50035
GENERAL DESCRIPTION
The universal isolated converter DAT 4530 is able to measure and linearise voltage, current and resistance signals, potentiometers and the standard
thermocouples and RTDs with, if required, the cold junction compensation, the wires compensation. For mV, V and mA input it is possible to set an
option for the fast sampling (option HS) or to extract the square root of the measured signal (option SQRT). In function of programming, the measured
values are converted in a current or voltage signal on the two outputs. Moreover an output contact is available as trip alarm.
By dip-switches accessible opening the window on the side of the enclosure, it is possible to select the input type and range and the output type without
recalibrate the device.
By Personal Computer the user can set the two outputs with independent settings, the parameters of the Trip Alarm and the optional parameters for his
own necessity;
The galvanic isolation between input, outputs and power supply eliminates the effects of all ground loops eventually existing and allows the use of the
converter in heavy environmental conditions found in industrial applications. The device guarantees high accuracy and performances stability both
versus time and temperature.
The DAT 4530 is in compliance with the Directive UL 61010-1 for US market and with the Directive
CSA C22.2 No 61010-1 for the
Canadian market.
It is housed in a plastic enclosure of 12.5 mm thickness suitable for DIN rail mounting in compliance with EN-50022 and EN-50035 standards.
USER INSTRUCTIONS
The connections must be made as shown in the section "Connections".It is possible to configure the converter on field by dip-switch or Personal
Computer as shown in the section “ Programming ". The configuration by dip-switches can be made also if the device is powered (note: after the
configuration the device takes some seconds to provide the right output measure ).
Output type
Min
Max
Min Span
Output resolution
Current
7 uA
Voltage
4 mV
Burn-out values
Max. output value
22 mA or 11 V
Min. output value
0 mA or -0.6 V
Current
0 mA
20 mA
4 mA
Voltage
0 V
10 V
1 V
Response time
(10÷ 90%)
about
400 ms
100 ms (option HS)
Output load Resistance - Rload
Current output
< 500
W
Voltage output
> 10 K
W
Short circuit current
30 mA max.
OUTPUT (2 CHANNELS)
MECHANICAL SPECIFICATIONS
Material
Self-extinguish plastic
IP Code
IP20
Wiring
wires with diameter
0.8÷2.1 mm
2
/AWG 14-18
Tightening Torque
0.8 N m
Mounting
in compliance with DIN
rail standard EN-50022
and EN-50035
Weight
about 90 g.
Power supply voltage
20 .. 30 Vdc
Reverse polarity protection
60 Vdc max
Current consumption
Current output
90 mA max.
Voltage output
30 mA max.
ISOLATION
Among all the ways
1500 Vac,
50 Hz, 1 min
POWER SUPPLY
Input type
Min
Max
Span min
Accuracy
(1)
mV, TC
the higher of ±0.1% and ±12 uV
RTD
the higher of ±0.1% and ±0.2°C
Res.
the higher of ±0.1% and ±0.15
Potentiometer
± 0.05 % f.s.
Voltage
the higher of ±0.1% and ± 2 mV
mA
the higher of ±0.1% and ± 6 uA
mV, V, mA
± 0.5 % f.s (opt. HS)
RTD
(
2, 3, 4 wires)
Pt100
-200°C
850°C
50°C
Pt1000
-85°C
185°C
30°C
Ni100
-60°C
180°C
50°C
Ni1000
-60°C
150°C
30°C
RES.
(2, 3, 4 wires)
0
W
500
W
50
W
0
W
2000
W
50
W
INPUT
Voltage
-10 V
10 V
1 V
TC (
CJC int./ext
.)
J
-200°C
1200°C
100°C
K
-200°C
1300°C
100°C
S
0°C
1750°C
400°C
R
0°C
1750°C
400°C
B
0°C
1850°C
400°C
E
-200°C
1000°C
100°C
T
-200°C
400°C
100°C
N
-200°C
1300°C
100°C
Voltage
mV
-100 mV +90 mV
5 mV
mV
-100 mV +200 mV
10 mV
mV
-100 mV +800 mV
20 mV
(1) referred to the input Span (difference between max. and min.)
Pot.
(Rnom.< 50K
W
)
0
%
100
%
10
%
Current
0 mA
20 mA
1 mA
RTD/RES
V
mA
V
mA
Tc
mV
mA
V
Pot
Alarm
DC SUPPLY
+
-
ENVIRONMENTAL CONDITIONS
Operative Temperature
-20°C .. +60°C
UL Operative Temperature
-10°C .. +60°C
Storage Temperature
-40°C.. +85°C
Humidity (not condensed)
0 .. 90 %
Maximum Altitude
2000 m
Installation
Indoor
Category of installation
II
Pollution Degree
2
CERTIFICATIONS
EMC ( for industrial environments)
Immunity
EN 61000-6-2
Emission
EN 61000-6-4
UL
US Standard
UL 61010-1
Canadian Standard CSA C22.2 No 61010-1
CCN
NRAQ/NRAQ7
Typology
Open Type device
Classification
Industrial Control
Equipment
File Number
E352854