4-20mA Current Splitter

Phone: +1 561 779 5660 E-mail : [email protected] - Web Site www.datexel.com

 

 

DAT 4530

DAT 4530

Universal isolated converter

configurable by Dip-Switch or PC

double output & trip amplifier

 

TECHNICAL SPECIFICATIONS (Typical @ 25 °C and in nominal conditions)

Line resistance influence 

(1)

TC, mV

<=0.8 uV/Ohm

RTD 3w 

(50

W

 max balanced)

0.05%/

W

RTD 4w 

(100

W

 max balanced)

0.005%/

W

Linearity 

(1)

TC, RTD

± 0.1 % f.s.

mV, V, mA

± 0.05 % f.s. 

Thermal drift 

(1)

Full scale

± 0.01% / °C

CJC

± 0.01% / °C

RTD excitation current

RTD, Res

400 uA

CJC Comp.

 

± 0.5°C

Input impedance

TC, mV

>= 10 M

W

mA

~22 

W

Aux. Voltage

>18V @ 20mA

ALARM TRIP  (SSR)

Contact

SPST

Max Load (resistive) :
Voltage

48 Vdc / 30 Vac

Current

0.4 A

Aux. Voltage

>12V @ 20mA

FEATURES
- Universal configurable input for:

mV, Tc, RTD, Res, Potentiometer, V and mA

- Two outputs configurable in current or voltage
- Trip alarm
- Configurable by dip-switch or PC
- High accuracy
- On-field reconfigurable
- Galvanic isolation among all the ways
- UL / CE mark
- Suitable for DIN rail mounting in compliance
   with EN-50022 and EN-50035

GENERAL DESCRIPTION

The  universal isolated converter  DAT  4530  is  able  to  measure  and  linearise  voltage, current  and  resistance  signals,  potentiometers and the standard 

thermocouples  and  RTDs  with,  if  required,  the  cold  junction  compensation,  the  wires  compensation.  For  mV,  V  and  mA  input  it  is  possible  to  set  an 

option for the fast sampling (option HS) or to extract the square root of the measured signal (option SQRT). In function of programming, the measured 

values are converted in a current or voltage signal on the two outputs. Moreover an output contact is available as trip alarm.

By dip-switches accessible opening the window on the side of the enclosure, it is possible to select the input type and range and the output type without 

recalibrate the device.

By Personal Computer the user can set the two outputs with independent settings, the parameters of the Trip Alarm and the optional parameters for his 

own necessity;
The galvanic isolation between input, outputs and power supply eliminates the effects of all ground loops eventually existing and allows the use of the 
converter  in  heavy  environmental  conditions  found  in  industrial  applications.  The  device  guarantees  high  accuracy  and  performances  stability    both 
versus time and temperature.
The DAT 4530 is in compliance with the Directive UL 61010-1 for US market and with the Directive 

CSA C22.2 No 61010-1 for the

 Canadian market.

It is housed in a plastic enclosure of 12.5 mm thickness suitable for DIN rail mounting in compliance with EN-50022 and EN-50035 standards.

USER INSTRUCTIONS

The  connections  must  be  made  as  shown  in  the  section  "Connections".It  is  possible  to  configure  the  converter  on  field  by  dip-switch  or  Personal 
Computer  as  shown  in  the  section  “  Programming  ".  The  configuration  by  dip-switches  can  be  made  also  if  the  device  is  powered  (note:  after  the 
configuration the device takes some seconds to provide the right output measure ).

Output type

 

Min

 Max

Min Span 

Output resolution

Current

 7 uA

Voltage

 4 mV

Burn-out values

Max. output value 

22 mA or 11 V

Min. output value  

0 mA or -0.6 V

Current

 0 mA

20 mA

 4 mA

Voltage 

 0  V

10  V

 1  V

Response time 

(10÷ 90%)  

about 

 

400 ms

100 ms (option HS)

Output load Resistance - Rload

 

Current output

< 500 

W

Voltage output

> 10 K

W

Short circuit current       

30 mA max.

OUTPUT (2 CHANNELS) 

MECHANICAL SPECIFICATIONS

Material

 Self-extinguish plastic 

IP Code 

 IP20

Wiring

 wires with diameter
 0.8÷2.1 mm

2

 /AWG 14-18

Tightening Torque

 0.8 N m 

Mounting      

 in compliance with DIN 
 rail standard EN-50022 
 and EN-50035 

Weight

 about 90 g.

Power supply voltage

20 .. 30 Vdc

Reverse polarity protection

60 Vdc max

Current consumption 

Current output

90 mA max.

Voltage output

30 mA max.

ISOLATION

Among all the ways  

1500 Vac,
50 Hz, 1 min

POWER SUPPLY

Input type

 Min

 Max

Span min

Accuracy 

(1)

mV, TC

the higher of ±0.1% and ±12 uV

RTD

the higher of ±0.1% and ±0.2°C

Res.

the higher of ±0.1% and ±0.15 

Potentiometer

± 0.05 % f.s.

Voltage

the higher of ±0.1% and ± 2 mV

mA

the higher of ±0.1% and ± 6 uA

mV, V, mA

± 0.5 % f.s (opt. HS)

RTD 

(

2, 3, 4 wires)

Pt100

-200°C

850°C

 50°C

Pt1000

-85°C

185°C

 30°C

Ni100

-60°C

180°C

 50°C

Ni1000

-60°C

150°C

 30°C

RES.

 

(2, 3, 4 wires)

 0 

W

 500 

W

 50 

W

 0 

W

2000 

W

 50 

W

INPUT

Voltage

-10 V

 10 V

1 V

TC (

CJC int./ext

.)

J

-200°C

1200°C

 100°C

K

-200°C

1300°C

 100°C

S

0°C

1750°C

 400°C

R

0°C

1750°C

 400°C

B

 0°C

1850°C

 400°C

E

-200°C

1000°C

 100°C

T

-200°C

 400°C

 100°C

N

-200°C

1300°C

 100°C

Voltage

mV

-100 mV +90 mV

 5 mV

mV

-100 mV +200 mV

 10 mV

mV

-100 mV +800 mV

 20 mV

(1) referred to the input Span (difference between max. and min.)

Pot.

 

(Rnom.< 50K

W

)

  

%

100 

%

  

10 

%

Current

 0 mA

 20 mA

1 mA

RTD/RES

  

V

mA

V

mA

Tc

mV

mA

V

Pot

 

Alarm

DC SUPPLY

+

-

ENVIRONMENTAL CONDITIONS

Operative Temperature

 -20°C .. +60°C

UL Operative Temperature

-10°C .. +60°C

Storage Temperature       

-40°C.. +85°C

Humidity (not condensed)   

0 .. 90 %

Maximum Altitude

2000 m

Installation

Indoor

Category of installation

II

Pollution Degree

2

CERTIFICATIONS
EMC ( for industrial environments)

Immunity

 EN 61000-6-2

Emission

 EN 61000-6-4

UL

US Standard     

     UL 61010-1

Canadian Standard    CSA C22.2 No 61010-1
CCN

 NRAQ/NRAQ7

Typology

 Open Type device

Classification

 Industrial Control 
 Equipment      

File Number

 E352854

Содержание DAT 4530

Страница 1: ...ure of 12 5 mm thickness suitable for DIN rail mounting in compliance with EN 50022 and EN 50035 standards USER INSTRUCTIONS The connections must be made as shown in the section Connections It is possible to configure the converter on field by dip switch or Personal Computer as shown in the section Programming The configuration by dip switches can be made also if the device is powered note after t...

Страница 2: ...MMING CONFIGURATION BY DIP SWITCHES 1 Open the suitable door on the side of the device 2 Set the input type by the dip switch SW1 1 5 see TAB 1 3 Set the output A type by the dip switch SW1 7 8 and SW2 1 2 see TAB 2 4 Set if available the input option by the dip switch SW1 6 see TAB 3 5 Set the minimum input scale value Zero by the dip switch SW3 1 4 see TAB 4 6 Set the maximum input value Full sc...

Страница 3: ... V 0 20 mA SW2 2 1 4 20 mA 0 10 V 0 5 V Out B NOTES To set the input range refer to the TAB 4 next pages referred to the input type selected by the TAB 1 If the dip switches SW1 1 5 are all set in the position 0 EPROM the device will follow the configuration programmed by PC input type and range output type and range trip alarm s settings and options If the dip switches SW2 3 8 and SW3 1 4 are all...

Страница 4: ... W Full Scale SW2 6 5 4 3 Default 50 55 60 65 70 75 80 85 90 95 100 110 115 120 W 7 8 SW2 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 SW2 220 230 240 250 260 270 280 290 300 310 320 330 340 350 SW2 380 390 400 410 420 430 440 450 460 470 500 500 30 20 200 360 480 490 500 370 210 105 W W W 6 5 4 3 7 8 6 5 4 3 7 8 6 5 4 3 7 8 TAB 4d Resistance 500 ohm input scale settings Zero SW3 4 ...

Страница 5: ...0 20 2 5 2 11 25 15 5 20 20 20 16 11 5 mA mA mA mA mA 6 5 4 3 7 8 6 5 4 3 7 8 TAB 4f Current input scale settings Zero SW3 4 3 2 1 Default 0 1 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 5 8 Volt Full Scale SW2 6 5 4 3 Default 0 5 0 6 0 8 1 1 2 1 4 1 6 1 8 2 2 2 2 4 2 6 2 8 3 3 2 Volt 7 8 SW2 3 4 3 6 3 8 4 4 2 4 4 4 6 4 8 5 5 2 5 4 5 6 5 8 6 6 2 Volt SW2 6 8 7 7 2 7 4 7 6 7 8 8 8 2 8 4 8 6 8 8 9 9 2 9 4 Volt SW...

Страница 6: ...nal cables motors induction ovens inverters etc and to use shielded cable for connecting signals LIGHT SIGNALLING LED COLOUR STATE DESCRIPTION PWR GREEN ON OFF Device powered Device not powered BLINKING Wrong dip switches settings ALARM RED ON OFF Trip alarm active Trip alarm not active DAT 4530 Pt100 0 200 C 4 20 mA 4 20 mA 3wires Input type Input scale Out A scale Options Out B scale HOW TO ORDE...

Отзывы: