1 DATECS
DPP-350
Programmer’s manual VER.1.50
13
All
DC3
command except
DC3 P
and
DC3 p
are executed when ruled line mode is off, too. Su the ruled
line buffers can be cleared or set before this command.
The command
DC3 –
sets ruled lines off.
In page mode nothing is printed outside the selected using
ESC W
region.
The command does not clear rule line buffers.
By default ruled lines are disabled.
The command is supported in firmware version 1.48 or higher.
9.
Sets the ruled line OFF (
DC3 -
)
Code:
[13h] + [2Dh]
The command disables ruled line mode.
All
DC3
command except
DC3 P
and
DC3 p
are executed when ruled line mode is off, too. Su the ruled
line buffers can be cleared or set after this command.
The command
DC3 +
sets ruled lines on.
The command does not clear rule line buffers.
By default ruled lines are disabled.
The command is supported in firmware version 1.48 or higher.
10.
Selects ruled line buffer
A
(
DC3 A
)
Code:
[13h] + [41h]
Makes ruled line buffer
A
active.
All
DC3
commands for clearing or setting data use the active ruled line buffer. When ruled line is
enabled, then printing a line and commands
DC3 P
and
DC3 p
use this buffer.
By default buffer
А
is selected.
The command is supported in firmware version 1.48 or higher
.
11.
Selects ruled line buffer
B
(
DC3 B
)
Code:
[13h] + [42h]
Makes ruled line buffer
B
active.
All
DC3
commands for clearing or setting data use the active ruled line buffer. When ruled line is
enabled, then printing a line and commands
DC3 P
and
DC3 p
use this buffer.
By default buffer
B
is selected.
The command is supported in firmware version 1.48 or higher.
12.
Clears selected ruled line buffer (
DC3 C
)
Code:
[13h] + [43h]
Clears selected ruled line buffer (Sets all bits to 0).
After power on or command
ESC @
both buffers are clear.
Entering or leaving ruled line mode (
DC3 +
and
DC3 -
) does not clear ruled line buffers.
The command is supported in firmware version 1.48 or higher.
13.
Sets a single dot in selected ruled line buffer (
DC3 D
)
Code:
[13h] + [44h] + nL + nH
Set to ‘
1
’ one bit of the active ruled line buffer.
The dot coordinates are
nL+256*nH
. Coordinates outside the printable area are ignored.