How to update SE-2000 firmware
From time to time Datavideo may release new firmware to either add new features or to fix reported bugs in the
current mixer firmware. Customers can update the mixer firmware themselves if they wish or they can contact
their local dealer or reseller for assistance should they prefer this method.
This page describes the firmware update process, two programs will be used and it should take
approximately
40 minutes total time to complete
.
Once started
the update process should not be interrupted in any way
as this could result in a non-
responsive mixer.
As well as a working mixer you will need:
The latest Flash Update for the mixer. This can be obtained from your local Datavideo office.
The latest SetUp program for the mixer. See Page 20.
A 9 pin Sub D male to female RS-232 cable. Pin 1 connects to pin 1, pin 2 connects to pin 2, etc.
A Windows XP Professional 32bit PC with a 9pin Sub D COM1 port.
Save the two programs to the PC desktop so you can find them easily.
Stage 1
. Run the
FlashUpdate_SE2000_xxxx
program. (where
xxxx
represents the version number)
This first part of the update process should take 20 minutes to complete.
Ensure the mixer is switched OFF. Connect the mixer using the sub D 9pin cable between the PC COM1 port and
the mixer’s RS-232 port. Double click the
FlashUpdate_SE2000_xxxx
application.
Click NEXT then select the option for the COM1 port on the PC and click NEXT.