FCC Compliance Statement 

This device complies with part 15 of the FCC rules. Operation is subject to the following two 
conditions: 

1.

 

This device may not cause harmful interference, and  

2.

 

This device must accept any interference received, including interference that may cause 
undesired operation.

 

Warnings and Precautions 

1.

 

Read all of these warnings and save them for later reference. 

2.

 

Follow all warnings and instructions marked on this unit. 

3.

 

Unplug  this  unit  from  the  wall  outlet  before  cleaning.  Do  not  use  liquid  or  aerosol 
cleaners. Use a damp cloth for cleaning. 

4.

 

Do not use this unit in or near water. 

5.

 

Do  not  place  this  unit  on  an  unstable  cart,  stand,  or  table.  The  unit  may  fall,  causing 
serious damage. 

6.

 

Slots and openings on the cabinet top, back, and bottom are provided for ventilation. To 
ensure safe and reliable operation of this unit, and to protect it from overheating, do not 
block  or  cover  these  openings.  Do  not  place  this  unit  on  a  bed,  sofa,  rug,  or  similar 
surface, as the ventilation openings on the bottom of the cabinet will be blocked. This 
unit should never be placed near or over a heat register or radiator. This unit should not 
be placed in a built-in installation unless proper ventilation is provided. 

7.

 

This product should only be operated  from the type of power source indicated on the 
marking  label  of  the  AC  adapter.  If  you  are  not  sure  of  the  type  of  power  available, 
consult your Datavideo dealer or your local power company. 

8.

 

Do  not  allow  anything  to  rest  on  the  power  cord.  Do  not  locate  this  unit  where  the 
power cord will be walked on, rolled over, or otherwise stressed. 

9.

 

If an extension cord must be used with this unit, make sure that the total of the ampere 
ratings  on  the  products  plugged  into  the  extension  cord  do  not  exceed  the  extension 
cord rating. 

10.

 

Make  sure  that  the  total  amperes  of  all  the  units  that  are  plugged  into  a  single  wall 
outlet do not exceed 15 amperes. 

11.

 

Never  push  objects  of  any  kind  into  this  unit  through  the  cabinet  ventilation  slots,  as 
they may touch dangerous voltage points or short out parts that could result in risk of 
fire or electric shock. Never spill liquid of any kind onto or into this unit. 

12.

 

Except as specifically explained elsewhere in this manual, do not attempt to service this 
product  yourself.  Opening  or  removing  covers  that  are  marked  “Do  Not  Remove”  may 
expose you to dangerous voltage points or other risks, and will void your warranty. Refer 
all service issues to qualified service personnel. 

13.

 

Unplug this product from the wall outlet and refer to qualified service personnel under 
the following conditions: 
a.

 

When the power cord is damaged or frayed; 

Содержание CCU-200

Страница 1: ...HDBASET CCU 200 CAMERA CONTROL UNIT Instruction Manual ...

Страница 2: ...is intended as a guide only At all times Datavideo Technologies will try to give correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be correct or may be incomplete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check t...

Страница 3: ...provided 7 This product should only be operated from the type of power source indicated on the marking label of the AC adapter If you are not sure of the type of power available consult your Datavideo dealer or your local power company 8 Do not allow anything to rest on the power cord Do not locate this unit where the power cord will be walked on rolled over or otherwise stressed 9 If an extension...

Страница 4: ... purchase date is unknown the product warranty period begins on the thirtieth day after shipment from a Datavideo office All non Datavideo manufactured products product without Datavideo logo have only one year warranty from the date of purchase Damage caused by accident misuse unauthorized repairs sand grit or water is not covered under warranty Viruses and malware infections on the computer syst...

Страница 5: ... collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact you...

Страница 6: ... an external power supply during long distance video transmission With a CB cable the CCU 200 system simultaneously handles digital SDI and analogue signals for camera video output Program look back video camera view finder data as well as tally and intercom signals between the cameras and a video switcher The Datavideo AD 3 Multi Transmission Adaptor Box establishes connection between the CCU 200...

Страница 7: ... in each direction are listed below CCU 200 to AD 3 Control Signals issued from MCU 400 Multi Camera Control Unit Power for Camera s Look Back Monitors Intercom System Signal Look Back Signal Switcher s Program Out Tally Light Signal from Switcher AD 3 to CCU 200 Camera HDMI Video ITC 300 Intercom System Signal ...

Страница 8: ...rcom signal and tally between CCU 200 and AD 3 Note See Chapter 5 for pinout information LED Indicators The top row consists of power indicators for CB connections Turning ON the device power turns ON the green LEDs Note When the power is shorted or overloaded the green LEDs will go out and the device must be rebooted The bottom row consists of HDBaseT connection indicators First connect the CB ca...

Страница 9: ...ote Connect the DC 48 IN to VMC 1 separate purchase RS 232 422 Port The CCU 200 also allows you to connect and control non Datavideo cameras via RS 232 422 ports See Chapter 6 for cable pinouts DIP Switch Use the DIP switch to switch between RS 232 and RS 422 Bit 1 sets port 1 bit 2 sets port 2 and etc Push up to enable RS 232 push down to enable RS 422 Note If you are using RS 232 RS 422 to contr...

Страница 10: ... the external devices are ITC 300 Digital Intercom System and MCU 400 Multi Camera Control Unit The Control ports transmit audio and control signals Note If your external devices are non Datavideo and do not have Ethernet ports try to connect via RS 232 or RS 422 interface See CCU 200 Front Panel and AD 3 Side Panel for details Mini USB Port For firmware upgrade Note Please connect a laptop to upg...

Страница 11: ...attached to the rear of the camera by a standard V Mount plate as shown in the diagram below It can also be used like a V Mount Battery to power the camera If the standard V Mount plate is not found on the rear of the camera the user can purchase a SLED SLD 1 off the shelf from Datavideo ...

Страница 12: ...utton Press to switch between Main and AUX views on TLM 700K Look Back Monitor MAIN Camera video AUX Look back video Note It is normal that you will see about 0 5 seconds of video flicker or color distortion when using this button to switch between Main and AUX Audio noise can sometimes be heard too ...

Страница 13: ...al Intercom System via the CCU 200 HDBaseT Camera Control Unit Follow the steps outlined below to operate Call and Talk buttons 1 Press the Call button and the AD 3 s corresponding channel button on the ITC 300 should start flashing red 2 To talk the ITC 300 operator should press the flashing channel button and when the channel button turns solid green the two way communication has then been estab...

Страница 14: ...adset Jack The camera operator may connect a headphone or headset to this 3 5 mm jack which establishes bidirectional audio signal transmission between AD 3 and the connected headphone or headset The headset may be connected to this 3 5 mm jack via a music TRS adapter in the CCU 200 product package Press the Talk button on the front panel to speak to ITC 300 Main Unit operator Volume Control Knob ...

Страница 15: ... Intercom System as well as enable Look Back monitor mode Cable pinouts are depicted below Ext Tally OUT Delivers AD 3 s tally signal to TD 3 LED Tally Light Camera Look Back Video HDMI OUT This port sends Camera Look Back Video to the TLM 700K Look Back Monitor RES Button The RES button allows you to change the HDMI OUT video resolution When the input video resolution is 25 or 50 fps the output r...

Страница 16: ... modes which are PIP Mode POP Mode Single Mode Note It is normal that you will see 0 5 seconds of video flicker when using the PIP button to switch between display modes PIP Mode PIP Mode POP Mode POP Mode Single Mode Single Mode DVIP Port Connect a BC 100 Block Camera to this port See the system diagram in Section 2 ...

Страница 17: ...o connect and control non Datavideo cameras via RS 232 422 ports If you plan to use RS 232 RS 422 to control the cameras the corresponding AD 3s must also be connected via RS 232 RS 422 See Chapter 6 for cable pinouts DIP Switch Bit 1 2 RS 232 0 0 RS 422 1 0 V Mount Base V Mount base mounts AD 3 to the rear of the camera ...

Страница 18: ... 17 5 CB 65 66 Pinouts ...

Страница 19: ... 18 ...

Страница 20: ...te Blue 5 TX TX 6 Green Green 6 RX NC 7 White Brown White Brown 7 NC NC 8 Brown Brown 8 NC CCU 200 HDBaseT Camera Control Unit to MCU 400 Multi Camera Control Unit CCU 200 Main Unit MCU 400 Mulit Camera Control Unit GND 1 White Orange White Orange 1 GND NC 2 Orange Orange 2 NC RX 3 White Green White Green 3 TX TX 4 Blue Blue 4 RX TX 5 White Blue White Blue 5 RX RX 6 Green Green 6 TX NC 7 White Bro...

Страница 21: ...RX 4 Blue 2 TX RX 5 White Blue 1 TX TX 6 Green 3 RX NC 7 White Brown NC 8 Brown CCU 200 HDBaseT Camera Control Unit to Sony RM B170 Camera Controller CCU 200 Main Unit Sony Camera Controller Remote Port GND 1 White Orange 7 GND NC 2 Orange RX 3 White Green 2 TX TX 4 Blue 4 RX TX 5 White Blue 3 RX RX 6 Green 1 TX NC 7 White Brown NC 8 Brown GND GND ...

Страница 22: ...NC TX 6 Green Green 6 RX NC 7 White Brown White Brown 7 NC NC 8 Brown Brown 8 NC CCU 200 HDBaseT Camera Control Unit to MCU 400 Multi Camera Control Unit CCU 200 Main Unit MCU 400 Mulit Camera Control Unit GND 1 White Orange White Orange 1 GND NC 2 Orange Orange 2 NC NC 3 White Green White Green 3 NC TX 4 Blue Blue 4 RX NC 5 White Blue White Blue 5 NC RX 6 Green Green 6 TX NC 7 White Brown White B...

Страница 23: ...bes problems that you may encounter while using CCU 200 If you have questions please refer to related sections and follow all the suggested solutions If problem still exists please contact your distributor or the service center No Problems Solutions 1 2 ...

Страница 24: ... 23 8 Dimensions CCU 200 AD 3 All measurements in millimeters mm ...

Страница 25: ... 300 Intercom Tally LED Indicators Power LED x 4 Power supply indicator ON Green HDBaseT Link LED x 4 HDBaseT link indicator Link activated Yellow AC Power AC IN 100 240VAC 50 60Hz DC Power UPS DC IN 48V 350W Max AD 3 Camera Adaptor Specifications Camera OUT 17 Pin Jack x 1 CB cable transmits HDBaseT signal video audio and control power look back video intercom signal and tally between CCU 200 and...

Страница 26: ... power 14 8V MAX 35W Supplied by V Mount Battery Intercom System Headset 3 5mm Headphone or Headset Jack x 1 Headset Headphone Impedance 24 ohm 100mW min Microphone Impedance 680 ohm Sensitivity 45 2dB Tip MIC Ring Phone Sleeve GND Tally OUT Jack 3 5mm Jack Connects TD 3 Tally Indicator Tip Red Ring Green Sleeve GND Communication Activation Buttons Button x2 Call and Talk Volume Control VR with mu...

Страница 27: ... 26 Notes ...

Страница 28: ...Feb 03 2020 Version E2 Datavideo Technologies Co Ltd All rights reserved 2020 www datavideo com product CCU 200 ...

Отзывы: