20
PREPARING FOR THE INSTALLATION
INTRODUCTION
UPS
Input Data
Nominal input voltage
DC24V
Input voltage range
DC22V~DC26V
Buffer time
0.5Hr~1Hr (Depending on POS system and configuration.)
Output Data in Normal Operation
Nominal output voltage
DC 21.09V ~ 23.31V
Output current
2.7A
Current limit
9A
Charging
Charge characteristic
curve
Liner mode
End-of-charge voltage
DC12.6V
Charge current
DC1.35A (C.C. Mode under DC 12.6V)
Ambient temperature
Operation/storage
0°C to +40°C / 20°C to +70°C
Humidity At +25°C
5%~ 95%, no condensation
Other
MTBF (Bellcore mode /
Not including Battery Set)
A target calculated MTBF of the power supply is greater than
200,000 hours under the following condition: 24Vdc input, Full
rated load, 25°C ambient