D T - 6 X X X BiSync to Async ASCII Printer Application U s e r ' s M a n u a l
B u i l d 9 . 0
04/18/06
Datatek Applications Inc.
10
2.3.1 UMI
C
ONFIGURATION
The overall configuration process for the UMI can be divided into two phases:
1.
Base Configuration:
setting up the
UMI
for IP connectivity and console security
2.
Operational Configuration:
setting up the
UMI
and BNS node to enable users to make calls
between the BNS and IP networks
2.3.1.1 B
ASE
C
ONFIGURATION
The following console output reflects the output of the UMI
verify
command
(part of UMI Module
command set)
. The results displayed below describe a UMI Base Configuration consistent with
the configuration needs of the previous network diagram. For a more detailed description of how
to configure the UMI, refer to the
UMI User's Manual
.
<UMI> verify vport 33
Virtual Ports 33 - 33 :
Type ==>
TCP Port 12000 w/Call Listen.
Service State ==>
In Service.
Protocol ==>
Synchronous.
2.3.1.2 O
PERATIONAL
C
ONFIGURATION
The following console output reflects the output of the UMI
verify
command
(part of UMI Node
command set)
. The results displayed below describe a UMI Operational Configuration consistent
with the configuration needs of the previous network diagram. For a more detailed description of
how to configure the UMI, refer to the
UMI User's Manual
.
CC0> vfy sam m p 17 2 1
MODULE ADDRESS:
17
MODULE TYPE:
sam504
NCHLS:
512
SERVICE STATE:
in
SECS BEFORE DISCONNECT:
50
TRUNK TYPE:
t1
LINE SPEED:
1.544M
TOTAL BOARDS:
16
DOWNLOAD SERVER:
controller
VERSION:
standard
COMMENT:
UMI
BOARD SERVICE SOFTWARE
ADDR STATE VERSION
2
in
standard
DEV NWK ATT ATT
PORT TYPE FC FC XANY BAUD CHAR ACT PARITY SRVC BILL VDM GROUP
1 term N/A N/A N/A 9600 N/A N/A N/A in off N/A tn6XXX
CALL NODE BLD CABLE STOP CNST
PORT HOLD RBAUD ECHO NRZI PAP OUT TYPE BITS BITS PROTO CODE CARR
1 N/A N/A N/A no no 254 dce N/A N/A bisync ebcdic no
PORT EPN CUG PROFILE BFLUSH FRMFILL
1 N/A N/A
PORT PDD
1 bscprt
PORT COMMENT