1-12
Part No. 001-4008-101
GENERAL SPECIFICATIONS
These specifications are subject to change without notice.
*380 to 403 MHz frequency band is not FCC or IC type approved
+
Includes 102 cm power cable.
General RF Specifications
(
RF Specifications are measured per TIA/EIA-603 with a psophometric baseband filter.)
1
Cold Start: time from DC power applied until unit is fully ready to receive or transmit data
2
Warm Start Rx: in power saving modes (sleep or suspend), wake-up time for full receiver recovery
3
Warm Start Tx: in power saving modes (sleep or suspend), wake-up time for full transceiver operation
4
Tx Turnon Time: typical Rx to Tx switching time for stable transmission
GENERAL
VHF
UHF
900 MHz
Frequency
132-174 MHz
380-403 MHz*
403-512 MHz
928-960 MHz
Channels
Multi-channel capability under system PLC control
Channel Bandwidth
6.25, 12.5 or 25 kHz models
Operating Temperature
-30
!
to + 60
!
C
Supply voltage
10 - 16 VDC maximum (nominal 13.3)
Fuse protected against reverse voltage (internal surface mount 3A fuse: not field replaceable)
Rx Current Drain at 13.3 VDC
<220 mA (with a terminal connected to Integra-TR COM port)
Tx Current Drain at 13.3 VDC
<2.6 A
Power Saving Mode Current Drain
<20 mA
Cold start
1
4 sec (typical)
Warm Start Rx
2
45 to 60 msec (depending on radio model and temperature)
Warm Start Tx
3
55 to 70 msec (depending on radio model and temperature)
Tx Turnon Time
4
15 ms (typical)
Rx/Tx Bandwidth, without tuning
18 MHz (132-150)
24 MHz (150-174)
16 MHz except
20 MHz (450-470)
32 MHz
RECEIVER
VHF
UHF
900 MHz
Sensitivity
0.35
"
V for 12 dB SINAD
Selectivity (25 kHz)
>70 dB minimum
> 65 dB minimum
Selectivity (12.5 kHz)
>60 dB minimum
>60 dB minimum
Selectivity (6.25 kHz)
>40 dB minimum
N/A
Intermodulation
>70 dB minimum
> 70 dB minimum
Spurious Rejection
>70 dB minimum
>70 dB minimum
FM Hum and Noise
<-45 dB max (25 kHz)
<-45 dB max (25 kHz)
<-40 dB max (25 kHz)
Conducted Spurious
< -57 dBm
TRANSMITTER
VHF
UHF
900 MHz
RF Power Output
1 to 5 Watts, software adjustable
Spurious and Harmonics
<-73 dBc (-36 dBm)
<-73 dBc (-36 dBm)
-57 dBc (-20 dBm)
Frequency Tolerance (12.5 & 25 kHz)
2.5 PPM
1.5 PPM
1.5 PPM
Frequency Tolerance (6.25 kHz)
1.0 PPM
.5 PPM
N/A
FM Hum and Noise
<-45 dB (25 kHz)
<-45 dB (25 kHz)
<-40 dB (25 kHz)
Tx Duty Cycle
50%, max. Tx time 30 seconds, extended Tx time with the cooling fan option