Страница 1: ...INTEGRA H Version TechnicalManual...

Страница 2: ...d data market including SCADA systems for utilities petrochemical waste and fresh water management markets and RF boards for OEM applications in the Radio Frequency Data Capture market PRODUCT WARRANT...

Страница 3: ...ols Configuration settings allow tailoring for a variety of application requirements Integra H supports 1 Point to point configuration in switched simplex mode 2 Point to multipoint configuration Sett...

Страница 4: ...AL SERVICE The Technical Service Department provides customer assistance on technical problems and serves as an interface with factory repair facilities They can be reached in the following ways Datar...

Страница 5: ...r repair will be returned to the customer re tuned to the current Dataradio Test and Tune Procedure and will conform to all specifications noted in this section Customers are responsible for shipping...

Страница 6: ...to allow field upgrades Upgrades are done using a PC connected to the Integra H but do not require opening the unit Upgrades require interaction with DRL s Technical Service 1 10 INSTALLATION 1 10 1...

Страница 7: ...t to antenna Result reduction of 4 dB Figure 1 1 Sample Equation Graphic 1 10 3 ACCEPTABLE ANTENNAE The antennae listed in Table 1 2 were tested and typed for maximum gain These antennae are FCC appro...

Страница 8: ...errain and antenna system To assure reliable communications the RF radio frequency path between stations should be studied by a competent professional who can determine what antennae are required and...

Страница 9: ...OINT TO POINT SYSTEM A simple point to point connection is shown in Figure 1 3 Figure 1 3 Point to Point System In this system the user s equipment DTE is set up in a master remote configuration 1 11...

Страница 10: ...described in the preceding sections Figure 1 5 Landline Tail Circuit Note The phone line modems should be full duplex units Figure 1 6 DCE Crossover Cable for RTS CTS mode Some point to point FDX land...

Страница 11: ...oint Multipoint Repeater Master Store and Forward Device Integra H Integra H Remote Remote Remote Integra H Integra H Integra H Integra H RS 232 Serial RS 232 Serial Data line harness RS232 Serial Mas...

Страница 12: ...ty 10 6 BER 105 dBm 9600 bps Intermodulation 75 dB Spurious Rejection 80 Conducted Spurious 70 Secondary Image 65 dB TRANSMITTER RF Power Output 100 1 Watt software adjustable Spurious and Harmonics F...

Страница 13: ...only via offline diagnostics Absolute maximum input voltage 20 Vdc Inputs are reverse voltage protected Display 4 Bi color status LEDs RUN PWR CS SYN RX TX RD TD Connectors RF SMA Female COM DE 9F SE...

Страница 14: ...ly prohibited FCC Industry Canada Required antenna impedance is 50 ohms The installer of this equipment must ensure the antenna does not emit an RF field in excess of Health Canada limits for the gene...

Страница 15: ...e the signals correctly See the documentation for your data equipment for further information 2 2 6 COM PORT Baud rates from 300 to 19200 are supported Integra s are factory set default for 9600 b s 8...

Страница 16: ...Function 1 DCD Output Always asserted or asserted when receive RF carrier present selectable via RSS 2 RXD Output Data from Integra H to DTE 3 TXD Input Data from DTE to Integra H 4 DTR Input Ignored...

Страница 17: ...stics format 2 3 REAR PANEL Figure 2 4 Integra H rear panel 2 3 1 HEAT SINK The rear panel heat sink is essential for proper operation of the Integra H transmitter The unit must be mounted in a locati...

Страница 18: ...used the green and white wires should be cut back and or taped to prevent contact See Table 1 1 for power cable part number 2 3 4 ANALOG CONNECTIONS The two analog connections can be programmed as inp...

Страница 19: ...are configuration and should not be changed in the field b Rx Tp With the Rx Tp selected the output signal performs as the receiver demodulated audio signal test point Rx Tp The Rx Tp should measure 1...

Страница 20: ...commodate some RTU s special timing requirements Set to normal 15 ms unless advised otherwise by technical support Do not use fast 5 ms timer below 2400 baud 2 4 3 SENDING BREAK SIGNALS Integra H may...

Страница 21: ...tation Type This is a 1 bit value used to identify the station as a master or remote See 2 4 6 2 4 6 STATION TYPE On simplex or repeater networks all remote stations can hear the master and many remot...

Страница 22: ...p port communicates with the RDS using a proprietary protocol However if a terminal or PC running terminal software is connected to the Setup port online diagnostic information will be delivered in pl...

Страница 23: ...ine and offline diagnostics Differences will be noted where they exist in the text For simplicity we continue to assume that diagnostics are being collected at the master station 2 5 2 1 Short ID Onli...

Страница 24: ...l be in the range of 110 to 60 dBm depending on network speed with higher values i e less negative values indicating a stronger signal Reliability of data reception depends largely on signal strength...

Страница 25: ...nvestigation 1 Forward power output in watts drops or rises by more than 10 from its established value Reflected power remains low This indicates that the transmitter may need alignment or that a comp...

Страница 26: ...t the receive quality indicator thus returned is a composite value which represents the average reception from the last 15 remotes Any significant drop in the receive quality indicator returned by the...

Страница 27: ...there is no carrier or no data was decoded the unit goes into low power consumption mode for the duration of the Suspend period The Suspend period can be set via the RSS to any value between 50 to 120...

Страница 28: ...ering is beyond the scope of this manual However there are some simple tips that can be used to optimize performance of a radio based SCADA or telemetry system Choose the best protocol Some SCADA devi...

Страница 29: ...on a 9600 b s network will increase data transmission delays and reduce system performance Evaluate the need for online diagnostics Enabling online diagnostics increases delays by 2 5 to 10 ms dependi...

Страница 30: ...maintenance personnel 3 2 EQUIPMENT REQUIRED The adjustments described below require the following equipment 1 13 3 VDC 2A regulated power supply 2 Radio service monitor IFR1200 or equiv 3 Cable with...

Страница 31: ...support at least 1 watt 2 Connect Integra H to the power supply and adjust the supply voltage to 13 3 volts WARNING Do not exceed 16 VDC during setting up for tests and adjustments 3 Using a 9 conduct...

Страница 32: ...ra H RF input Raise the service monitor RF output until the CS LED comes on The CS LED should be off The CS LED should come on within 2 dB from the value set by the INTRSS Default approx 105 dBm 110 i...

Страница 33: ...on l Check RF power output from the connected unit by using the Carrier test button The RSSI bar graph will turn to a divided wattmeter Forward and Reflected power l Check carrier frequency from the u...

Страница 34: ...ed Between 1 254 FPWR Approximate measure of transmit RF power If power read from Bar graph or from reported diagnostics Note If power read from an external wattmeter RPWR Approximate measure of refle...

Страница 35: ...volt from 6 0 to 18 8 volts WARNING Do not exceed 16Vdc Application of more than 16 VDC will damage the unit and is not covered by the warranty Should nominally be close to 13 3VDC Operating limits 10...

Страница 36: ...re inactive during test transmissions 4 7 TX TONE The TX Tone is used mainly to check transmit deviation To send a modulated carrier press the TX Tone button l If Source is Local sends a 1200 Hz sine...

Страница 37: ...nsmit Deviation Connected to an Integra H Part Number 242 4090 XY0 Native Compatibility Mode Network Speed in b s Typical Deviation kHz Voltage at Pin 4 when receiving that deviation from other units...

Страница 38: ...Preamble ms 0 Network Speed 9600 19200 21400 25600 Tx Time Out 30 sec ON Tx Online Diagnostics Yes Unit Type Master Data Delivery All Suspend Period ms 0 Activity Time out sec 5 Sleep Mode Disable N...

Страница 39: ...The lower 32K are used for the firmware program and the upper 32K by the CMOS RAM U18 The memory IC used for the program is a CMOS FLASH U22 with 1024 sectors of 128 bytes each The dual Z84015 circui...

Страница 40: ...e RS 232 driver and to the user port 6 2 5 INTEGRA H A D AND DIGIPOT An 8 channel 8 bit successive approximation A D converter type ADC0838 U4 is interfaced to CPU U17 and Peripheral U21 CH0 and CH1 a...