2
Part No. 004-3282-004
TRANSMIT OUTPUT LEVEL
The transmit carrier level to the transceiver is factory preset
for 400 mVrms. This input level is required by a Dataradio
transceiver connected to the modem. To change the factory
input level, follow steps d through g:
d. If necessary, remove the modem board from the housing
as described in Step a.
e. Configure the telemetry equipment connected to the RS-
232 jack to transmit a continuous data signal. If no
equipment is connected to the jack, configure S101 with
switches 1 and 7 ON. Then move switch 6 to ON to key-up
the modem. The modem will transmit a continuous
alternating space/mark tone from U230.
f. Monitor the AC voltage at TP400, J102. Adjust R400 for
400 mVrms if using a DRL telemetry transceiver. If
another transceiver is used, adjust R400 as required. J103
pin 5 has a resistor that will drop the Tx output level to
40 mVrms when connected to the DRL JSLM / RNet.
g. Re-install the modem board in the housing.
3282 LEDS
The 3282 has 2 LEDs (CR220) that are visible through the
adjustment hole in the case closest to the 10 pin connector.
One LED will flash green whenever the modem has power
and the microcontroller U220 is operating correctly. The
other red LED will be solid red whenever the modem is
transmitting.
Figure 3 ALIGNMENT POINTS
Table 3 SWITCH S101 SETTINGS FOR BELL 103/202
DIP Switch S101
Operating Mode
Baud
Rate
Full/
Half
Dup
Tx Freq
Rx Freq
1
2
3
4
5
Space
Mark
Space
Mark
(0=Off, 1=On)
Normal Modes
0
-
1
-
1
Bell 103 Answer
300
Full
2025
2225
1070
1270
0
-
1
-
0
Bell 103 Originate
300
Full
1070
1270
2025
2225
0
-
0
-
1
Bell 202 Full-Duplex
1200
Full
2200
1200
2200
1200
0
-
0
-
0
Bell 202 Half-Duplex
1200
Half
2200
1200
2200
1200
1
2
3
4
5
Loopback Modes
1
-
1
-
1
Bell 103 Answer Loopback
300
Full
2025
2225
2025
2225
1
-
1
-
0
Bell 103 Originate Loopback
300
Full
1070
1270
1070
1270
1
-
0
-
1
Bell 202 Main Loopback
1200
Full
2200
1200
2200
1200
1
-
0
-
0
Bell 202 Main Loopback
1200
Full
2200
1200
2200
1200
R400
Transmit Output
Level Adjust
A Tuning tool should be used to
perform adjustments on R400. This
tool is available from DRL’s
Customer Service as part number