background image

2

Part No. 004-3282-004

TRANSMIT OUTPUT LEVEL 

The transmit carrier level to the transceiver is factory preset 
for 400 mVrms. This input level is required by a  Dataradio 
transceiver connected to the modem. To change the factory 
input level, follow steps d through g:

d. If necessary, remove the modem board from the housing 

as described in Step a. 

e.  Configure the telemetry equipment connected to the RS-

232 jack to transmit a continuous data signal. If no 
equipment is connected to the jack, configure S101 with 
switches 1 and 7 ON. Then move switch 6 to ON to key-up 
the modem. The modem will transmit a continuous 
alternating space/mark tone from U230.

f. Monitor the AC voltage at TP400, J102. Adjust R400 for 

400 mVrms if using a DRL telemetry transceiver. If 
another transceiver is used, adjust R400 as required. J103 
pin 5 has a resistor that will drop the Tx output level to 
40 mVrms when connected to the DRL JSLM / RNet.

g.   Re-install the modem board in the housing.

3282 LEDS

     

The 3282 has 2 LEDs (CR220) that are visible through the 
adjustment hole in the case closest to the 10 pin connector. 
One LED will flash green whenever the modem has power 
and the microcontroller U220 is operating correctly. The 
other red LED will be solid red whenever the modem is 
transmitting.

Figure 3 ALIGNMENT POINTS

Table 3   SWITCH S101 SETTINGS FOR BELL 103/202

DIP Switch S101

Operating Mode

Baud

Rate

Full/

Half
Dup

Tx Freq

Rx Freq

1

2

3

4

5

Space

Mark

Space

Mark

(0=Off, 1=On)

                              Normal Modes

0

-

1

-

1

Bell 103 Answer

300

Full

2025

2225

1070

1270

0

-

1

-

0

Bell 103 Originate

300

Full

1070

1270

2025

2225

0

-

0

-

1

Bell 202 Full-Duplex

1200

Full

2200

1200

2200

1200

0

-

0

-

0

Bell 202 Half-Duplex

1200

Half

2200

1200

2200

1200

1

2

3

4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loopback  Modes

1

-

1

-

1

Bell 103 Answer Loopback

300

Full

2025

2225

2025

2225

1

-

1

-

0

Bell 103 Originate Loopback

300

Full

1070

1270

1070

1270

1

-

0

-

1

Bell 202 Main Loopback

1200

Full

2200

1200

2200

1200

1

-

0

-

0

Bell 202 Main Loopback

1200

Full

2200

1200

2200

1200

    

  

R400 

Transmit Output 

     Level Adjust

          

A Tuning tool should be used to  
perform adjustments on R400. This 
tool is available from DRL’s         
Customer Service as part number 
721-0015-142S. 