background image

1

Part No. 004-3282-004

DL-3282 MODEM 

SETUP INSTRUCTIONS

INTERCONNECT CABLE INSTALLATION

This modem requires a power source with an operating 
voltage range of 7 - 16 Vdc. 

Note: A transceiver may 

require a more restrictive operating range

.

 

*

See Figures 4 and 5 for pinout details.

The 3282 interfaces with user equipment through the DB-
25 RS232 connector. See Figure 1 for pinout details

.

DEFAULT FACTORY SETTINGS

Normal
Conventional
Bell 202
Half Duplex
Active High Squelch
FSK Audio
240 ms RTS to CTS Delay
100 mS Soft Carrier Turnoff debounce time
Transmit Input Level (pre-set for 400 mVrms)

The factory default setting for the RTS to CTS delay time is 
set to the maximum delay for compatibility with a wide 

range of products. When used with  DRL synthesized radios 
(DL-3400 and JSLM/RNet) a shorter delay time (30ms) may 
be used

 

(refer to Tables 2 through 4 and Figure 3). Follow 

steps a through c under setup switch S101.

RECEIVE INPUT LEVEL

 

For proper operation of the modem, the carrier level from 
the transceiver should be 35 mVrms -1mVrms (or 99 mVp-
p - 2.8 mVp-p). DRL transceivers (DL-3400) are factory 
adjusted to provide a data level output to the modem of 707 
mVrms (or 2 V p-p). The data level output to the modem 
when used with the DRL JSLM/RNet is 212 mVrms + 17.5 
mVrms (or 0.6 V p-p + 0.05 V p-p).

ADJUSTMENTS

There are two adjustments on the modem board. These 
adjustments have been set at the factory and may require 
further adjustment in the field for your application.

DIP Switch S101
Transmit Level Adjust R400

Figure 2 DIP SWITCH S101 (DEFAULT SETTINGS)

SETUP SWITCH S101

a. To access S101 and make other adjustments, remove the 

modem board from the housing by removing the 2 screws 
on the RS-232 connector, the corner screws from the op-
posite end of the housing, and the top cover screw. Slide 
the modem board out.

b. Set the switches as indicated in Tables 3 and 4 (0=Off, 

1=On). 

c. Re-install the modem board in the housing unless 

performing adjustments described in the following two 
sections.

Table 1   3282 INTERCONNECT CABLES

TRANSCEIVER 
MODEL

DRL CABLE #

CONNECTOR TYPES

3400

023-3410-125

10-Pin (2)

*

 

(to spade terminals)

RNet / JSLM

697-3282-012

DE-15 (1) & DA-15 (1)

*

Table 2  RS-232 CONNECTOR PINOUT

      

  RS-232 PINOUT

1 Shield_GND                 J101-1

2 RS232_DCE RXD         J101-2

3 RS232_DCE TXD        J101-3

4 RS232_RTS                   J101-4

5 RS232_CTS                  J101-5

6 RS232_DSR                  J101-6

7 RS232_GND                 J101-7

8 RS232_DCD                 J101-8

20 RS232_DTR               J101-20

7

8

9

10

11

12

6

5

4

3

2

13

1

14

15

16

17

18

19

20

21

22

23

24

25

S101

7

8

1

2

3

4

5

6

ON

ON

N

O

R

M

A

L/

LO

O

P

   

   

   

 C

O

N

V

EN

TI

O

N

A

L

B

EL

20

2/

10

3

SQ

U

EL

C

H

 IN

V

ER

T

H

A

LF

/F

U

LL

 D

U

PL

EX

O

PT

1

O

PT

2

O

PT

3

0

1

1

Figure 1  RS-232 Connector