background image

DI-789 Hardware Manual

Installation

11

here. The software will go to that IP address and retrieve the MAC address for you. This will save further setup 
in the TCP/IP Manager. Click 

OK

 to continue. 

Note: If you enter the wrong MAC address you will have to re-run 

this installation program with the correct MAC address to access the device.

14. Click 

Yes

 in the “More ethernet devices to install” dialog box if you are installing multiple Ethernet devices.

15. Repeat Steps 12 and 13 until all Ethernet devices’ MAC addresses have been entered. Click 

No

 to continue 

installation.

16. The “Installation Option” dialog box allows you to specify access to W

IN

D

AQ

 for multiple users on the same PC. 

If you are the only user or you would like to allow access to all users click 

Yes

. If there are multiple users and 

you would like to be the only one able to access W

IN

D

AQ

 click 

No

. Click 

Cancel

 to abort the installation.

17. Select the desired options for installation of W

IN

D

AQ

/XL and Advanced CODAS.

18. Installation is complete. Run the TCP/IP Manager via the Windows program group specified during W

IN

D

AQ

 

Software installation (default is 

Start > Programs > WINDAQ > IP Manager

) to access the device and run 

W

IN

D

AQ

 Acquisition Software.

Connecting the Device

After power has been applied, install the DI-789 anywhere in a chain of Synchronous Ethernet instruments. Multiple 
Ethernet products may be daisy-chained together to allow for one synchronous distributed data acquisition system. 
Any combination of multiple DI-789s or Synchronous Ethernet instruments may be placed in the same daisy chain. 
To maintain synchronicity, Ethernet hubs and switches cannot be used between units. Make sure to enter each MAC 
address during installation. Daisy-chains must be installed to your Local Area Network (LAN) — you cannot access 
more than one device per IP address outside of your subnet. If you are not sure whether or not the devices are in your 
subnet see your system administrator before installation. You may acquire data from only one daisy chain at a time 
(i.e., the same PC cannot access two daisy chained groups at the same time).

Note: If you are installing a daisy-chained group of instruments for the purpose of synchronous distributed data 
acquisition, do not allow any other units or daisy chains to be installed to your subnet. Running other devices on the 
same subnet will cause the synced units to become unsynced.

1.

Connect one end of a CAT-5 Ethernet cable to the 

Toward PC

 port of the first Ethernet device.

2.

Connect the other end of the same CAT-5 Ethernet cable to the Ethernet port on your PC or LAN.

3.

Connect one end of another CAT-5 Ethernet Cable to the 

Expansion

 port on the rear of the first Ethernet device.

4.

Connect the other end of the same CAT-5 Ethernet cable to the 

Toward PC

 port on the second Ethernet device.

5.

Continue installing more Ethernet devices by connecting a CAT-5 Ethernet cable to the 

Expansion

 port of the 

last device in the chain and the 

Toward PC

 port on the next device you are adding to the chain. Up to 32 devices 

Содержание Ethernet DI-789

Страница 1: ...ical manual or otherwise without expressed written authorization from the com pany The distribution of this material outside the company may occur only as authorized by the company in writing DATAQ In...

Страница 2: ......

Страница 3: ...products that have been repaired or altered by persons other than DATAQ Instru ments employees or products that have been subjected to misuse neglect improper installation or accident DATAQ Instrument...

Страница 4: ......

Страница 5: ...Hub Switch 5 Installing a DI 789 to a Synchronous chain on network without a DHCP server 8 Installing a DI 789 to a Synchronous Chain on a network with a DHCP Server 9 Installing Software 10 Connecti...

Страница 6: ......

Страница 7: ...to setup DI 789 instruments is included with purchase TCP IP Manager The DATAQ Instruments TCP IP Manager allows you to effectively manage and run multiple DI 72x 730 78x instru ments installed or con...

Страница 8: ......

Страница 9: ...hernet activity LED green Downstream Ethernet activity LED green Lost Synchronization LED red Rear Panel none Power Voltage Range 9 36 VDC Power Requirements 5 Watts Environmental Operating Temperatur...

Страница 10: ......

Страница 11: ...9 to a Synchronous Chain that is Directly Connected to your PC or Connected via a Hub Switch Installation of an Ethernet Synchronous chain of devices directly connected to the network card on your com...

Страница 12: ...n 4 Select Internet Protocol TCP IP in the This connection uses the following items window and click on the Properties button 5 Click on the General tab 6 Select the radio button Use the following IP...

Страница 13: ...connect your PC to a network or router you should change the TCP IP proper ties back to their original state 10 Install WINDAQ software see Installing Software on page 10 11 Run the TCP IP Manager sof...

Страница 14: ...s could instead be routers with DHCP turned off i e a static IP assigned network Contact your system admin istrator for details about your network 1 Have the system administrator designate an IP addre...

Страница 15: ...gned automatically by a DHCP server or router you will need to change the device settings using the Dataq TCP IP Manager See the Dataq Instruments TCP IP Manager help file for complete details Install...

Страница 16: ...OK 7 The Welcome dialog box allows you to cancel the installation Click OK to continue installation or Cancel to abort 8 Read through the Software License agreement carefully and either Accept and Co...

Страница 17: ...ynchronous distributed data acquisition system Any combination of multiple DI 789s or Synchronous Ethernet instruments may be placed in the same daisy chain To maintain synchronicity Ethernet hubs and...

Страница 18: ...g procedure to apply power to your DI 789 instrument 1 Plug the five pin DIN end of the power adapter cable into the five pin jack labeled POWER on the rear panel of the instrument 2 Plug the appropri...