Page 4 

Configuration 

Setting I/P Address 

 
The COE-8 units provide two methods for setting the IP Address 

1)  Static IP via the Web Page Setup 
2)  DHCP 

 

WEB Page 

 
Login to the COE-8 and access the Setup pages by clicking on the 

Setup

 button from the home page.  

Click on the IP button to bring up the IP Settings page: 
 

 

 
Select Static Mode from the radio buttons and fill in the IP Address, Subnet Mask and Gateway as 
provided by your network administrator.  Click Apply to save the changes.  You will then be prompted to 
reboot the COE-8.  Click on the Reboot button.  The COE-8 will reboot and the new IP address will be 
ready to be accessed. 
 

DHCP 

 
Selecting DHCP from the IP Setup page allows a DHCP server to provide IP address information to the 
COE-8.   Click Apply and then Reboot when prompted.  The COE-8 will reboot and will have to be 
accessed with the IP address assigned by the DHCP server.  If no IP address is assigned by a DHCP 
server, the original IP address will be retained.   

Содержание COE-8

Страница 1: ...O has eight relays that will mirror the status of the eight inputs of the COE 8I Each unit can be monitored and configured from a Web Browser Each channel of the COE 8I is independently configurable a...

Страница 2: ...DC Maximum Carrying Current 2 A Maximum Switching Power 60 AV 24 W Maximum Switching Voltage 120 VAC 60 VDC Maximum Switching Current 1A Life Expectancy 5 Million Operations Mechanical 100K Operations...

Страница 3: ...p the COE 8 units WEB Page Access The web pages provide status information on the inputs and outputs of the COE 8 as well as provide configuration for the unit Open a browser to the default or current...

Страница 4: ...Subnet Mask and Gateway as provided by your network administrator Click Apply to save the changes You will then be prompted to reboot the COE 8 Click on the Reboot button The COE 8 will reboot and the...

Страница 5: ...for web browser access that port must specifically be used in the URL when accessing the COE 8 For example if the Web Port is changed to 9090 then the URL for the unit would be http 192 168 1 254 9090...

Страница 6: ...there is a change of state on any COE 8 channel Check the box provided to enable this If both the COE 8I and COE 8O are configured to send traps two messages will be received by each SNMP manager for...

Страница 7: ...967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY DOES...

Отзывы: