background image

DNS-1640 User Manual 

17 

Features and Specifications 

 

 

Features: 

Redundant SIM Modules and Power Supplies 

Active-Active Dual 6GB/s 

SAS I/O Module

 Ar-

chitecture 

Support full path fail-over function which pro-
vides data redundancy 

Support Drive Auto Detection and Hot Swap 

Integrated RAID card management tool via 
SES2 

Connectivity Features: 

Two 6Gb/s SAS-IN ports in each SIM module 
provides host connectivity 

Support up to 96 drives by daisy-chaining 
JBODs. 

Connected and managed by RAID controller 

Connect to 6Gb/s SAS Expander 

Support Direct Attach  

Support daisy-chain of JBODs 

DNS 1640 is a high-availability, cost-effective 
2U SAS (Serial Attached SCSI) to SAS (Serial 
Attached SCSI) JBOD, which provides 24 pcs 
2.5” hard drive carriers to support various 
types of hard drive, including 6Gb/s SAS hard 
drive, and 6Gb/s SATA III hard drive with in-
terposer card. In addition to 24 pcs hard drive 
carriers, DNS-1640 system supports two 550W 
Full Redundant Power Supplies and two SIM 
modules. 

High Reliability: Redundant SIM modules, 
power supplies modules design secure “No 
Single-Point Failure”. Active-Active Dual 
6Gb/s SAS I/O Module Architecture, hot-
swappable hard disk, and dual SAS and SATA 
II paths with Interposer Card ensure that DNS-
1640 has high reliability and achieves 24x7 
availability. 

High Scalability: Each DNS-1640 system sup-
ports a maximum of 24 6Gb/s SAS/SATAIII 
hard disks per system, and up to 96 drives by 
daisy-chaining JBOD. 

High Flexibility: DNS-1640 system supports 
both SAS and SATA disks depending on cus-
tomer’s needs. This feature provides the most 
cost-effective storage pools for different kinds 
of data and provides a better management 
for ILM (Information Life Cycle Management) 
applications. 

High Performance: The Active-Active Dual 
6Gb/s SAS I/O Module Architecture ensures 
high system performance

Содержание DNS-1640

Страница 1: ...DNS 1640 2U 24 Bays 6Gb s SAS JBOD Dual path Dual I O User Manual Version QS0003 Copyright 2014 DataON Storage All rights reserved www dataonstorage com ...

Страница 2: ...charges of static electricity Working on computers that are still connected to a power supply can be extremely dangerous Follow these guidelines to avoid damage to the DNS 1640 or injury to yourself Always disconnect power when carrying out work inside the unit If possible wear a grounded wrist strap when carrying out work inside the unit Alternatively discharge any static electricity by touching ...

Страница 3: ...Screws 96 System requirements Servers with supported HBA Raid adapter refer to DNS 1640 support matrix reference for complete listing of supported adapters SFF 8088 to SFF 8088 SAS cable s Model Model DNS 1640SM DNS 1640DM DNS 1640S DNS 1640D Hard Drive Type SATA SSD SATA SSD SAS SSD SAS SSD SAS I O Module 1 2 1 2 DNS BJMB 2 5 Interposer 12 12 0 0 Technical Support Contact your system supplier ...

Страница 4: ... the Storage Enclosure No Component Color Lights On Lights Off 1 Fault LED Amber A component within the storage en closure needs attention Normal 2 Locate LED Flashing Blue Identifies a storage enclosure Normal 3 Power Green Power On Power Off 1 2 3 ...

Страница 5: ...ith the right direction All SAS IN OUT connectors are SFF 8088 Power Connector Power Supply Module 1 SIM Board 1 SAS 2 Connector SAS 3 Connector Power Supply Module 2 SAS 1 Connector Power Supply Module 2 Power Connector SIM Board 1 SAS 2 Connector SAS 3 Connector SAS 1 Connector SAS 2 Connector SAS 3 Connector SAS 1 Connector SIM Board 2 Power Supply Module 1 ...

Страница 6: ...1 Fault Amber PHY connection cannot estab lished correctly No error had occurred 4 SAS 1 Active Green PHY connection established correctly No connection 5 SAS 3 Fault Amber PHY connection cannot estab lished correctly No error had occurred 6 SAS 3 Active Green PHY connection established correctly No connection 7 Locate LED Flashing Blue Identifies SIM Normal 8 SIM Fault Amber Fault exist Normal 9 ...

Страница 7: ...Board LED Description No Component Color Lights On Lights Off 1 DC Power Green DC Power On No DC Power 2 Locate LED Blue Identifies Power Module Normal 3 PSM Fault Amber Fault exist Normal 4 AC Power Green AC Power On No AC Power 1 2 3 4 ...

Страница 8: ...A will be blank Blinking Green Spin up Accessing 2 HDD status Blank HDD Ok Blinking Blue Identify HDD Solid Orange HDD fault Blinking Or ange Blue RAID Rebuilt Blinking Blue HDD is ready to remove HDD Activity LED will be blank HDD Tray 1 2 Optional DNS BJMB 9252 6Gb s SAS Interposer for 2 5 SATA SSD HDD Disk Tray Handle Release button ...

Страница 9: ...an where you will be placing the disk drives These figures represent fully loaded DNS 1640 system with HDD However the same guidelines apply even if you are filling some of the HDD slots with blank disk trays in the mix ing HDD setting Recommended Mixing SAS SATA HDD Configurations Unsupported SAS SATA HDD Combinations SAS HDD SATA HDD Do not include SAS and SATA HDD in the same section SAS HDD SA...

Страница 10: ... 1640 User Manual 9 Follow these steps below to Install Replace HDD in the disk tray Step 1 a Press the release button and open the disk tray handle b Remove HDD carrier by pulling the disk tray handle out ...

Страница 11: ...2 Insert the HDD inside the tray and tighten the four 6 4 screws on the SATA SAS disks SATA disk SAS disk Important If using SATA HDD please make sure having DNS BJMB Interposer card installed on the back of HDD Interposer for SATA ...

Страница 12: ...DNS 1640 User Manual 11 Step 3 Slide in the HD tray back in the disk slot and close the disk tray handle Step 4 Repeat Step 1 through 3 if you wish to install more HDD into the DNS 1640 storage ...

Страница 13: ...commended to connect each power connector to separate power circuit If necessary refer to the documentations shipped with the 6Gb s SAS HBA RAID card for hardware and driver installation instructions There are different types of SAS Cables in the market make sure you order the right one for DNS 1640 For DNS 1640 it all uses SFF 8088 to SFF 8088 SAS Cable when connecting DNS 1640 to host and when d...

Страница 14: ...ng up DNS 1640 System Connection type 1 Single SIM This illustration shows one host with a HBA RAID card connected to four DNS 1640 with single SIM SFF 8088 to SFF 8088 SAS Cable 1st DNS 1640 2nd DNS 1640 3rd DNS 1640 4rh DNS 1640 ...

Страница 15: ...nnected to four DNS 1640 with dual SIM Important Not All HBA RAID card support this type of connection please refers to DNS 1640 support matrix reference for complete listing of supported dual port HBA RAID cards SFF 8088 to SFF 8088 SAS Cable RAID HBA CARD 1st DNS 1640 2nd DNS 1640 3rd DNS 1640 4th DNS 1640 ...

Страница 16: ...reakers are in OFF position 2 Connect the two provided power cables from the DNS 1640 to cabinet power strips 3 Lock down the two power cord latch 4 Connect the power cables from the cabinet to separate power circuits in your facility Note Cabinet is not included in the package Only the universal rails kit for the cabinet are provided Power Strip 1 Power Strip 2 ...

Страница 17: ... 1 Verify that all connections are correct 2 Turn on both circuit breakers on cabinet 3 Make sure that power on LED on all DNS 1640 are steady blue 4 Power on the host lastly Important Please make sure power on all DNS 1640 first before the server ...

Страница 18: ... 6Gb s SATA III hard drive with in terposer card In addition to 24 pcs hard drive carriers DNS 1640 system supports two 550W Full Redundant Power Supplies and two SIM modules High Reliability Redundant SIM modules power supplies modules design secure No Single Point Failure Active Active Dual 6Gb s SAS I O Module Architecture hot swappable hard disk and dual SAS and SATA II paths with Interposer C...

Страница 19: ...ensions The chassis dimensions measured at 17 5 W X 6 875 H X 18 5 D Sheet metal case only not including bezel and rear module handle Management Features Intergated with RAID Card management tool via SES2 LED Indicators for SM Modules Hard Drives Power Supplies and FAN Status AC Power Input Voltage 100 240 V AC Input Frequency 50 60Hz Output Power 550W Operating Environment Operating Temperature 0...

Отзывы: