3.4.3 Manual Media Calibration
The Manual Media Calibration is intended for use when Quick Media Calibration printer has failed to detect
the start of each label. This procedure performs a complete recalibration of the sensors and will optimize
the printer to your media. In some instances you may need to perform a Quick Media Calibration after the
Manual Media Calibration to further optimize the printer’s sensor.
When updating the printer’s firmware the sensor settings can be saved to a configuration
file, (see section 3.7) which will eliminate the need to re-calibrate the printer.
Sensor calibration is needed to set up either the black mark or the gap value of the media sensor on the
printer. The Manual Media Calibration can be performed using the NETira CT configuration utility, (see
section 3.3 for more information on NETira CT).
Launch the NETira CT configuration utility, and query (connect) to the printer.
Procedure for Gap Type Media:
(be sure the printer is set to sense Gap media, see Section 3.4.1).
1) Click on the ‘Sensor Calibration’
printer component.
2) Click the ‘Manual Media’ button
to start the manual calibration
process.
Follow the instructions on the
following screen.
3) Select the Interlabel/Gap radio
button then click ‘OK’.
4) Load Stock: Place the face of
media over the sensor, close
the door then click ‘OK’.
5) Load Special Backing Media for
Gap: Peel the label(s) off
backing and place backing over
the sensor and close the door
then click ‘OK’.
6) Remove Stock: Remove all
media from printer, close the
door then click ‘OK’.