48
I-Class
System Settings (continued)
;
Note:
As indicated, the following menu selections will only appear
according to the model of your printer.
PLUS EMULATION
This instructs the firmware to process
specific DPL data as would the
Prodigy Plus
®
printer without all of the
variations. The calculated Column
position based on 200 DPI using a 203
DPI printhead.
ENABLED
This list of exceptions will be updated
with new firmware releases:
Data Terminator – I 2 of 5 Barcodes
(IDs D, J, and L), the first non-
numeric character processed will
terminate the barcode data field.
Bar Size – I 2 of 5 Barcode (ID L),
when the bar size is specified
greater than P (25), the size is
automatically decreased to 10.
Human Readable Fonts – The EAN
and UPC barcodes (IDs B, C, F, G,
M, and N) print a fixed font size.
Lines and boxes: Rotations 2 and 4
are affected by the vertical multi-
plication factor defined in the DPL
Dxx command.
Column positions greater than the
printhead width are adjusted back to
the printable area and printed.
DISABLED
The above exceptions are disabled.
I-4206, I
-4208,
&
I
-4212
M
ode
ls
Содержание I-Class