6. Select the Paper Sensor Type button until your paper type appears. The options
are as follows:
Gap
Mark on Bottom
Notch
Continuous
Note:
For more information, refer to the section “Top-of-Form Sensor.”
7. Select the Ribbon Mode button until the correct option appears. The options are as
follows:
None
Coated In (CSI)
Coated Out (CSO)
Note:
For more information, refer to the section “Top-of-Form Sensor.”
Note:
CSI ribbon (shiny side facing outward) should be installed where the ribbon unwinds in
a counter-clockwise direction. CSO ribbon (dull side facing outward) should be installed where
the ribbon unwinds in a clockwise direction. If these settings do not match the ribbon type
being used, the ribbon supply hub will turn in the wrong direction.