7
W ARN I N G
Failure t o properly configure t he GPI O Port can result in dam age t o t he print er and / or connect ed devices.
GPI / O Por t B Ove r vie w
Pin
Sign a l N a m e / D ir e ct ion
[ 1]
Ju m pe r
Posit ion
Fu n ct ion / D e scr ipt ion
I nst alled
Print er + 5VDC is used ( .5 am p m axim um ) .
N ot e :
Drawing m ore t han .5 am ps can cause unreliable print er operat ion.
1
+ 5 VDC
JMP 11
Rem oved
+ 5VDC m ust be supplied.
2
I nput 6
N/ A
N/ A
Program m ed input funct ion.
3
I nput 3
N/ A
N/ A
Program m ed input funct ion.
I nst alled: Pins 1 – 2
Program m ed out put funct ion pulled- up t o + 5VDC.
I nst alled: Pins 2 – 3
Program m ed out put funct ion pulled- up t o + 24VDC.
4
Out put 6
JMP 7
Rem oved
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not 30VDC.
I nst alled: Pins 1 – 2
Program m ed out put funct ion pulled- up t o + 5VDC.
I nst alled: Pins 2 – 3
Program m ed out put funct ion pulled- up t o + 24VDC.
5
Out put 3
JMP 4
Rem oved
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not 30VDC.
I nst alled
Print er chassis is used.
6
Ground
JMP 10
Rem oved
Ground m ust be supplied.
7
I nput 5
N/ A
N/ A
Program m ed input funct ion.
8
I nput 2
N/ A
N/ A
Program m ed input funct ion.
I nst alled: Pins 1 – 2
Program m ed out put funct ion pulled- up t o + 5VDC.
I nst alled: Pins 2 – 3
Program m ed out put funct ion pulled- up t o + 24VDC.
9
Out put 5
JMP 6
Rem oved
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not 30VDC.
I nst alled: Pins 1 – 2
Program m ed out put funct ion pulled- up t o + 5VDC.
I nst alled: Pins 2 – 3
Program m ed out put funct ion pulled- up t o + 24VDC.
10
Out put 2
JMP 3
Rem oved
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not 30VDC.
11
+ 24 VDC
N/ A
N/ A
Print er + 24 VDC ( 1.5 am p m axim um ) .
12
I nput 4
N/ A
N/ A
Program m ed input funct ion.
13
I nput 1
N/ A
N/ A
Program m ed input funct ion.
I nst alled: Pins 1 – 2
Program m ed out put funct ion pulled- up t o + 5VDC.
I nst alled: Pins 2 – 3
Program m ed out put funct ion pulled- up t o + 24VDC.
14
Out put 4
JMP 5
Rem oved
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not 30VDC.
I nst alled: Pins 1 – 2
Program m ed out put funct ion pulled- up t o + 5VDC.
I nst alled: Pins 2 – 3
Program m ed out put funct ion pulled- up t o + 24VDC.
15
Out put 1
JMP 2
Rem oved
An ext ernal volt age via ext ernal pull- ups will det erm ine t his level, not 30VDC.
[1]
Signal directions given relative to the printer.