Appendix J – General Purpose Input Output Ports
Class Series Programmer’s Manual
235
WARNING
Failure to properly configure the GPIO Port can result in damage to the printer and / or connected devices.
Applicator Interface Card (Version 2) GPI/O Port A Overview
Pin
Number
Signal Name
Signal
Direction
[1]
Jumper
Position
Function / Description
Installed
Printer chassis is used.
1
Ground
JMP 8
Removed
Ground must be supplied.
Installed
P5VDC is used (.5 amp maximum)
Note:
Drawing more than .5 amps can cause unreliable printer operation
.
2
+5 VDC
N/A
JMP 9
Removed
+5VDC must be supplied.
3
Start Of Print
[2]
Programmable
4
Slew Label
Programmable
5
Toggle / Pause
The printer pauses when the signal is taken LOW.
6
Reprint
Input
The last label is reprinted exactly, with no increment or time stamp changes;
recommended for use during error conditions. Always keeping this signal LOW results
in non-stop printing.
7
+24 VDC
P24 VDC (1.5 amp maximum)
8
Ground
N/A
N/A
N/A
Printer chassis.
9
Ribbon Low
Programmable
[1]
. Signifies a RIBBON LOW DIAMETER warning condition.
10
Service Required
Evoked by occurrences listed under ‘Fault Messages.’
[1]
Active LOW.
11
End Of Print
Programmable
[1]
. Signifies the End of Print (EOP) process.
12
Media Out
Evoked during an Out of Stock condition. Active LOW.
13
Ribbon Out
Evoked during an Out of Ribbon condition. Active LOW.
14
Data Ready
Evoked when a label is waiting to be printed. Then after the printer receives the Start of
Print signal, printing will begin. For synchronization with the print cycle, the End Of
Print signal indicates the completion of the print process. Active LOW.
15
Option Fault
Output
JMP 1
When inactive, outputs will be pulled up to
a voltage determined by this jumper setting,
where:
•
Pins 1 – 2 = +5VDC;
•
Pins 2 – 3 = +24VDC; or,
•
None = A common external voltage (not
to 30VDC) via external pull-ups
(providing a 20K ohm feedback path
through any two outputs).
Evoked during a Linear Scanner or RFID fault condition. Active LOW.
[1]
Signal directions are given relative to the printer.
[2]
If active with no current print job, “WAITING FOR DATA” will be displayed. Specifying a quantity of 9999 while keeping this signal ON will cause non-stop label printing, except in single label
“Imaging Mode”, which will cause the printer to stop between labels.
Содержание Ex2
Страница 2: ......
Страница 4: ......
Страница 15: ...xi Appendix V 281 Bar Code Symbology Information Resources 281 Glossary 283 ...
Страница 16: ...xii ...
Страница 30: ...Immediate Command Functions 14 Class Series Programmer s Manual ...
Страница 52: ...System Level Command Functions 36 Class Series Programmer s Manual ...
Страница 144: ...Label Formatting Command Functions 128 Class Series Programmer s Manual ...
Страница 162: ...Generating Label Formats 146 Class Series Programmer s Manual ...
Страница 182: ...Appendix D Reset Codes 166 Class Series Programmer s Manual ...
Страница 192: ...Appendix E Single Byte Symbol Sets 176 Class Series Programmer s Manual ...
Страница 236: ...Appendix G Barcode Details 220 Class Series Programmer s Manual ...
Страница 242: ...Appendix I Symbol Sets and Character Maps 226 Class Series Programmer s Manual ...
Страница 272: ...Appendix P UPC A and EAN 13 256 Class Series Programmer s Manual ...
Страница 282: ...Appendix R Plug and Play IDs 266 Class Series Programmer s Manual ...
Страница 296: ...Appendix U WiFi Region Country Codes 280 Class Series Programmer s Manual ...
Страница 302: ...Glossary 286 Class Series Programmer s Manual ...