E-3202 Programmer’s Manual
21
Miscellaneous Function and
Specific Commands
Miscellaneous Function Commands:
GS P x y : Set horizontal and vertical motion unit
ASCII
: GS P x y
Hexadecimal
: 1D 50 x y
Decimal
: 29 80 x y
0
≤
x
≤
255
0
≤
y
≤
255
This command sets the horizontal and vertical motion unit to 1 / x and 1 / y inches,
respectively. The default value are x = 200 and y = 400. When x and y are set to 0, the
default setting of each value is used.
ESC @ : initialize the printer
ASCII
: ESC @
Hexadecimal
: 1B 40
Decimal
: 27 64
Initializes the printer. The print buffer is cleared and the printer mode is reset to the mode
that was in effect when the power was turned on.
GS I n : Transmit printer ID
ASCII
: GS I n
Hexadecimal
: 1D 49 n
Decimal
: 29 73 n
1
≤
n
≤
3
n = 1 Name of the c Printer model
n = 2 if bit =1 Auto cutter equipped
n = 3 software version
ESC p m t1 t2 : Generate pulse
ASCII
: ESC p m
Hexadecimal
: 1B 70 n
Decimal
: 27 112 n
m = 0,1,48,49
0
≤
t1
≤
255
0
≤
t2
≤
255
Sends a pulse to the specified connector pin.
On time = t1 x 2 millisecond
Off time = t2 x 2 millisecond
m = 0 or 48 the pulse is sent to drawer kick out connector pin 2
m = 1 or 49 the pulse is sent to drawer kick out connector pin 5
ESC = n : Select peripheral device
ASCII
: ESC = n
Hexadecimal
: 1B 3D n
Decimal
: 27 61 n
0
≤
n
≤
255
This command selects the device to which the host computer sends data, based on the
value of n as follows :
Bit
Off/On
Hex
Dec
Function
0
Off
00
0
Printer disabled
On
01
1
Printer enabled
1 -7
-
-
-
Undefined
n = 1 : printer enabled
n = 0 : printer disabled
When the printer is disabled, it ignores all received data. The default setting is n = 1.
ESC L : Select page mode
ASCII
: ESC L
Hexadecimal
: 1B 4C
Decimal
: 27 76
This command switches from standard mode to page mode. This command is enabled
only when processed at the beginning of a line in standard mode ; it has no effect in page
mode. Standard mode is selected as the default.
ESC S : Select standard mode
ASCII
: ESC S
Hexadecimal
: 1B 53
Decimal
: 27 83
This command switches from page mode to standard mode. This command is effective
only in page mode. Data buffered in page mode is cleared. Standard mode is selected as
the default.
Содержание E-class E-3202
Страница 3: ......
Страница 5: ...ii...
Страница 9: ...4 E 3202 Programmer s Manual...
Страница 15: ...10 E 3202 Programmer s Manual...
Страница 23: ...18 E 3202 Programmer s Manual...
Страница 25: ...20 E 3202 Programmer s Manual...
Страница 35: ...30 E 3202 Programmer s Manual Table 850 Table 852...
Страница 36: ...E 3202 Programmer s Manual 31 Table 857 Table 860...
Страница 37: ...32 E 3202 Programmer s Manual Table 861 Table 863...
Страница 38: ...E 3202 Programmer s Manual 33 Table 869...