160
Target system
is the physical Printed Circuit Board (PCB), which contains the device to be in-
system programmed.
ISP programmer
is programmer, which has in-system programming capability (for example
DATAMAN-48PRO2, DATAMAN-48PRO2C, DATAMAN-40PRO …).
General rules for in-system programming
We recommended respect following rules to avoid damage PC, ISP programmer, and target
device or target system:
Ensure common earth point for target system, ISP programmer and PC.
For laptop or other PC that is not connected to common earth point: make hard - wired
connection from laptop to common earth point (for example use VGA connector).
Any devices connected to target system must be connected to common earth point too.
Direction of connect DATAMAN ISP programmer to target system:
During in-system programming you connect two electrical devices – ISP programmer and
target system. Unqualified connection can damage these devices.
Note:
When you don’t keep below directions and you damage programmer during in-system
programming, it is damage of programmer by unqualified manipulation and is out of warranty.
1. Turn off both devices – ISP programmer and target device.
2. Assign same GND potential for all devices, e.g. connect GND of all devices by wire.
3. Insert one connector of ISP cable to ISP programmer, turn on programmer and control
program.
4. In control program select target device and operation options.
5. Start action on target device (read, program).
6. After direction of control program, connect other ISP cable connector to target system and
turn on it.
7. After direction of control program, disconnect other ISP cable connector from target
system and turn off it.
8. If you need another action on target device, you continue with step 5.
The recommendation for design of target system with ISP programmed
device
The target system must be designed to allow all signals, which are use for In-system
programming to be directly connected to ISP programmer via ISP connector. If target system
use these signals for other function, is necessary isolated these signals. Target system mustn’t
affect these signals during In-system programming.
For in-system programmable devices manufacturers publish application notes. Design of
DATAMAN programmers together with respect of these application notes allows proper In-
system programming. Condition is exactly respecting these application notes.
Содержание 40PRO
Страница 7: ...Introduction 7 Introduction ...
Страница 12: ...12 Quick Start ...
Страница 15: ...Detailed description 15 Detailed description ...
Страница 16: ...16 DATAMAN 448PRO2 ...
Страница 30: ...30 DATAMAN 48PRO2 DATAMAN 48PRO2C ...
Страница 46: ...46 DATAMAN 40PRO ...
Страница 55: ...Setup 55 Setup ...
Страница 60: ...60 Step 8 Installation process will start Step 9 Click Finish button to finish setup ...
Страница 64: ...64 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway ...
Страница 66: ...66 PG4UW ...
Страница 133: ...PG4UWMC 133 PG4UWMC ...
Страница 146: ...146 Installation procedure customized ...
Страница 151: ...Common notes 151 Common notes ...
Страница 165: ...Troubleshooting and warranty 165 Troubleshooting and warranty ...