background image

Datalogic ADC, Inc.

959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140

©2012-2014 Datalogic, Inc.

An Unpublished Work - All rights reserved. No part of the contents of this documentation 
or the procedures described therein may be reproduced or transmitted in any form or by 
any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or 
affiliates ("Datalogic" or “Datalogic ADC”). Owners of Datalogic products are hereby 
granted a non-exclusive, revocable license to reproduce and transmit this documentation 
for the purchaser's own internal business purposes. Purchaser shall not remove or alter 
any proprietary notices, including copyright notices, contained in this documentation and 
shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by 
contacting your Datalogic representative. Electronic versions may either be downloadable 
from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you 
visit our website and would like to make comments or suggestions about this or other 
Datalogic publications, please let us know via the "Contact Datalogic" page.

Disclaimer

Datalogic has taken reasonable measures to provide information in this manual that is 
complete and accurate, however, Datalogic reserves the right to change any specification 
at any time without prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many 
countries, including the U.S.A. and the E.U. All other brand and product names may be 
trademarks of their respective owners.

Patents

See 

www.patents.datalogic.com

 for patent list.

This product is covered by one or more of the following patents:

Design patents: EP002137570, USD692892, ZL201230602800.2

Utility patents: EP0789315B1, EP1797521B1, US5992740, US6098883, US6454168, 
US6561427, US7506816

Содержание Touch TD1100 Family

Страница 1: ...Touch TD1100 General Purpose Corded Handheld Contact Imager Bar Code Reader Quick Reference Guide...

Страница 2: ...ou can acquire printed versions by contacting your Datalogic representative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media...

Страница 3: ...Keyboard Wedge Interface 8 Wand Emulation Interface 8 Scanning Modes 9 Scanning Modes continued 10 Troubleshooting 11 Technical Features 12 LED and Beeper Indications 14 Ergonomic Recommendations 14...

Страница 4: ...ii Touch TD1100 NOTES...

Страница 5: ...Documentation related to such product which has been purchased or otherwise acquired by End User whether obtained directly or indirectly from Datalogic 1 5 Software means any software or computer pro...

Страница 6: ...whether intentionally accidentally or by neglect or to unauthorized repair or unauthorized installation and shall be void if End User modifies the product uses the product in any manner other than as...

Страница 7: ...al between the parties concerning the licensing of the Software This Agreement may not be changed amended or modified except by written document signed by Datalogic 11 2 Notice All notices required or...

Страница 8: ...Software Product Policy vi Touch TD1100 NOTES...

Страница 9: ...codes Small lightweight and low on energy consumption the Touch TD1100 readers can still provide robustness and a 1 5 m 5 0 ft drop resistance which is typically included in a high er range of product...

Страница 10: ...Hands Free Stand The TD1100 Holder can be used as a hands free stand Refer to Scanning Modes on page 9 for in formation about programming the reader for use with the stand Figure 1 Hands Free Stand nd...

Страница 11: ...Setup Quick Reference Guide 3 Connect Host Interface Keyboard Wedge Interface K e y board RS 232 Interface USB Interface RS 2 3 2 RS 2 3 2 US B...

Страница 12: ...Setup 4 Touch TD1100 Touch and Scan 65 65...

Страница 13: ...esetting the Standard Product Defaults If you aren t sure what programming options are in your reader or you ve changed some options and want the factory settings restored scan the Factory Default Set...

Страница 14: ...odes 6 Touch TD1100 RS 232 Interface To use an RS 232 interface scan the bar code for the desired RS 232 host type Select RS 232 Standard Select RS 232 Wincor Nixdorf Select RS 232 OPOS for use with O...

Страница 15: ...supply is required When using a USB interface the reader auto de tects the USB and defaults to the USB Keyboard interface Select USB COM STD1 simulates RS 232 standard interface Select USB Keyboard w...

Страница 16: ...dard Key Encoding Select KBD AT NK IBM AT PS2 with standard key encoding but without external kbd Select KBD AT ALT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT NK for...

Страница 17: ...iple reads while in this mode Trigger Pulse Multiple When the trigger is pulled and released scanning is activated un til programmable duration1 has elapsed or the trigger has been pulled again to tra...

Страница 18: ...ing Modes 10 Touch TD1100 Scanning Modes continued Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Hands Free...

Страница 19: ...e of bar code scanned Refer to the Product Reference Guide PRG for more information Bar code label is unreadable Check the label to ensure it is not defaced Tryscanninganotherbarcode type Distance bet...

Страница 20: ...Linear Imaging Sensor Illumination Red LED 640 nm wavelength Print Contrast Ratio Minimum 25 Read Angle Pitch 65 Roll Tilt 45 Skew Yaw 70 Reading Indicators Beeper Adjustable Tone Good Read LED Resol...

Страница 21: ...dity 5 95 Drop specifications Withstands repeated drops from 1 5 m 5 0 ft onto a concrete surface Ambient Light immunity 0 20 000 lux Particulate and Water Sealing IP30 ESD Level 16 kV Regulatory LED...

Страница 22: ...etitive motion Maintain a natural position Reduce or eliminate excessive force Keep objects that are used frequently within easy reach Perform tasks at correct heights Reduce or eliminate vibration Re...

Страница 23: ...S which supplies power directly to the reader For the safety certification to be valid class III input power sources must be IEC EN60950 1 EN 60335 series EN 60065 or relevant approved Argentina Power...

Страница 24: ...ment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna Increase the separation between the equip...

Страница 25: ...Mercury Hg Cadmium Cd Hexavalent Chromium Cr VI Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PART Cable X O O O O O Printed Circuit Board Assy X O O O O O Assembly Module X O O O...

Страница 26: ...d chets lectroniques WEEE veuillez consulter le site internet www datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altger ten WEEE erhalten Sie auf der Webseite www datalog...

Страница 27: ...ic has no obligation to modify or update products once sold If Datalogic determines that a product has defects in material or workmanship Datalogic shall at its sole option repair or replace the produ...

Страница 28: ...al v any defect or damage caused by natural or man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusive events that would cause internal and e...

Страница 29: ...further information Products Search through the links to arrive at your product page where you can download specific Manuals and Software Utilities including Datalogic Aladdin a multi platform utilit...

Страница 30: ...Services and Support 22 Touch TD1100 NOTES...

Страница 31: ...omagn tique et la s curit des produits ber die Ann herung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Vertr glichkeit und Produktsicherheit entsprechen Basado en la aproximaci n d...

Страница 32: ...he Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 541 683 5700 Fax 1 5...

Отзывы: