REFERENCES
133
5
Stitching
This option enables/disables stitching for given symbology labels. When parts of a barcode
are presented to the reader with this feature enabled, the barcode parts will be assembled by
the reader’s software, and the data will be decoded if all barcode proofing requirements are
met.
Quiet Zones
This feature specifies the number of quiet zones for given symbology labels. Quiet zones are
blank areas at the ends of a barcode and are typically 10 times the width of the narrowest
bar or space in the label.
5.6.1 Concatenation
Concatenation Mode
Specifies the concatenation mode between Static and Dynamic. Static requires the
concatenated codes to be read in the same scan (simultaneously). Dynamic allows the two
codes to be read separately (within the specified Dynamic Concatenation Timeout.
Dynamic Concatenation Timeout
Specifies the timeout in 10-millisecond ticks used by the Dynamic Concatenation Mode.
To set this value:
1. Determine the desired setting in milliseconds (x 10 ms). (5-255).
2. Use the Chart
in
Appendix C
to find the hex equivalent for the desired numeric value.
3. Go to relative Dynamic Concatenation Timeout page
and scan the ENTER/EXIT
PROGRAMMING MODE barcode to enter Programming Mode.
4. Scan the barcode: SET TIMEOUT.
5. Scan the two hex equivalent characters from the keypad in
Appendix B
that represent the
numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure.
Содержание TC1200
Страница 1: ...TC1200 Reference Manual...
Страница 8: ...viii C ASCII HEX DECIMAL CHART 144 D RESERVED CHARACTERS 146...
Страница 57: ...Enter Exit Configuration PmI USB KBD 45 USB KEYBOARD SPEED CONTINUED 9 ms CKBSP09mR 10 ms CKBSP0Am3...
Страница 61: ...Enter Exit Configuration PmI READING PARAMETERS 49 LABEL PROGRAMMING MODE Disabled CFAPM00m Enabled CFAPM01m1...
Страница 124: ...Enter Exit Configuration CODE SELECTION PmI 112 STITCHING Disable CMSST00mz Enable CMSST01m...
Страница 154: ...TC1200 REFERENCE MANUAL 142 B B KEYPAD 0 0 1 2 1 2 3 4 3 4B 5 6 5D 6F 7 8 7H 8J 9 A 9L A B B...
Страница 155: ...KEYPAD 143 B C C D E Db Ed F Ff CANCEL o...
Страница 160: ...www automation datalogic com...