![Datalogic TC1200 Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/datalogic/tc1200/tc1200_reference-manual_4199290126.webp)
TC1200 REFERENCE MANUAL
114
5
5.1.2 RS232/USB
COM
Parameters
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the
beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in
10 ms increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in milliseconds (x 10 ms). (0-99).
2. Use the Chart
in
Appendix C
to find the hex equivalent for the desired numeric value.
3. Go to
page 39
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT INTERCHARACTER DELAY.
5. Scan the two hex equivalent characters from the keypad in
Appendix B
that represent the
numeric value determined in step 1 above.
NOTE
If you make a mistake before the last character, scan the CANCEL barcode
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit.
This completes the procedure.
Disable Character
Specifies the value of the RS232 host command used to disable the reader. Selections: a
character from NUL (0x00) to DEL (0x7F).
NOTE
The Enable Character must be different from the Disable Character and
must not contain reserved characters (see
Appendix D
). Setting to
previously defined characters such as XON, XOFF, or host commands
conflicts with normal operation of these characters. 8-bit data is not
recognized when the option Data Bits
has been set as 7 Data Bits.
To set the value:
1. Determine the desired character. A setting of 0xFF indicates the Disable Character is not
used (not available).
2. Use the Chart in
Appendix C
to find the hex equivalent for the desired character.
3. Go to
page 39
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
4. Scan the barcode: SELECT DEVICE DISABLE CHARACTER.
5. Scan the two hex equivalent characters from the keypad in
Appendix B
that represent the
desired character in step 1 above.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure.
Содержание TC1200
Страница 1: ...TC1200 Reference Manual...
Страница 8: ...viii C ASCII HEX DECIMAL CHART 144 D RESERVED CHARACTERS 146...
Страница 57: ...Enter Exit Configuration PmI USB KBD 45 USB KEYBOARD SPEED CONTINUED 9 ms CKBSP09mR 10 ms CKBSP0Am3...
Страница 61: ...Enter Exit Configuration PmI READING PARAMETERS 49 LABEL PROGRAMMING MODE Disabled CFAPM00m Enabled CFAPM01m1...
Страница 124: ...Enter Exit Configuration CODE SELECTION PmI 112 STITCHING Disable CMSST00mz Enable CMSST01m...
Страница 154: ...TC1200 REFERENCE MANUAL 142 B B KEYPAD 0 0 1 2 1 2 3 4 3 4B 5 6 5D 6F 7 8 7H 8J 9 A 9L A B B...
Страница 155: ...KEYPAD 143 B C C D E Db Ed F Ff CANCEL o...
Страница 160: ...www automation datalogic com...