CASCADE CONNECTION
INSTRUCTION MANUAL 31
CASCADE CONNECTION
Up to three SLIM light curtains can be connected in a cascade series.
The cascade connection allows to monitor up to three areas with only two Safety Out-
puts connected to Master unit.
Master unit takes care of collecting safety optic scan results from Slave units and the
synchronization between them to avoid mutual interference.
Each SLIM unit can either be used as Master or Slave, only depending on cable connec-
tion.
Figure 6 - Cascade composition
For cascaded system connection three Cascade Cables are available as accessory:
CS-H1-03-B-001
CASCADE cable 0.1 m
90
95A252950
CS-H1-03-B-005
CASCADE cable 0.5 m
490
95ASE2550
CS-H1-03-B-01
CASCADE cable 1 m
990
95ASE2560
Figure 7 - Cascade accessory cables
To connect the cascade unit:
•
Fix all cascade units with proper brackets as described in "
. (1)
•
Remove Terminator Caps at the end of Master and Slave 1 (if present) by loosen-
ing the two fixing screws for both emitter and receiver. (2)
•
Fasten the cascade cables in place of removed terminator caps, ensure all cables
bend radius it’s not less than 4mm (3)
•
Connect Slaves M12 male connectors to M12 Female connectors from cascade
cables (4).
Figure 8 - Mounting
MODEL
DESCRIPTION
L +/- 10 (mm)
CODE