![Datalogic SLIM Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/datalogic/slim/slim_instruction-manual_512573035.webp)
CASCADE RESOLUTION WITH DIFFERENT BRACKETS
INSTRUCTION MANUAL 25
CASCADE RESOLUTION WITH DIFFERENT BRACKETS
Fixing with “O” type brackets
Cascade resolution at junction drops to 40 mm.
Figure 8 - Fixing with “O” type brackets
Fixing with “C” type brackets
Cascade resolution at junction remains 14 mm.
Figure 9 - Fixing with “C” type brackets
Fixing with “L” type brackets
Cascade resolution at junction drops to 26 mm.
Figure 10 - Fixing with “L” type brackets