background image

 

ORIGINAL INSTRUCTIONS (ref. 2006/42/EC) 

This product is covered by one or more of the following patents. 

Italian Patent IT  1,363,719              Additional patents pending 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DECLARATION OF CONFORMITY 

We DATALOGIC AUTOMATION declare under our sole responsibility that these products are conform to the IEC 61496-1 
(2004) and IEC 61496-2 (2006) Standards and successive amendments 

WARRANTY 

DATALOGIC AUTOMATION warrants its products to be free from defects. 
DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be defective during the warranty 
period of 36 months from the manufacturing date. 
This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION 
products. 

 

DATALOGIC AUTOMATION - 

Via Lavino 265 

40050 Monte S.Pietro - Bologna – Italy 
Tel: +39 051 6765611 - Fax: +39 051 6759324 
www.automation.datalogic.com  e-mail:[email protected] 

 

 

DATALOGIC AUTOMATION cares for the environment: 100% recycled paper. 
DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification. 

Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, 

including the U.S.A. and the E.U. 

 

830000054 (Rev.D) 

© Copyright Datalogic 2009-2012 

Содержание SG2-B Series

Страница 1: ...e light curtain Precautions to be observed for the choice and installation of the device Make sure that the protection level assured by the SG2 device Type 2 is compatible with the real danger level of the machine to be controlled according to EN 954 1 and EN 13849 1 The outputs OSSD of the ESPE must be used as machine stopping devices and not as command devices The machine must have its own START...

Страница 2: ...tatus as shown in the table Correct alignment procedure The light curtain alignment can be effected only after having completed the mechanical installation and the electrical connections The following procedure has to be followed Check the green LED and the yellow LED on the TX unit If ON the emitter is running correctly Verify that the sensitive area from the safety light curtain is free Verify t...

Страница 3: ...d ON Light curtain working and in safety block conditions Function Type Check and repair LED OSSD error yellow and red BLINKING Check OSSD connections make sure that they are not in contact with one another or with the supply cables then Reset If the failure continues contact DATALOGIC AUTOMATION Internal error red ON yellow BLINKING Switch OFF and switch ON the supply circuit if the failure conti...

Страница 4: ...efective during the warranty period of 36 months from the manufacturing date This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION products DATALOGIC AUTOMATION Via Lavino 265 40050 Monte S Pietro Bologna Italy Tel 39 051 6765611 Fax 39 051 6759324 www automation datalogic com e mail info automation it datalogic com DATALOGIC AUTOMATION car...

Отзывы: