background image

Enter/Exit Programming Mode

Industrial 2 of 5

140

QuickScan™ I QD24XX/QBT24XX/QM24XX

Industrial 2 of 5 Check Character Transmission

Enables/disables transmission of an Industrial 2 of 5 check character.

$CU2CT00(CR)

Industrial 2 of 5 Check Character Transmission = Disable

$CU2CT01(CR)

Industrial 2 of 5 Check Character Transmission = Enable

DEFAULT

Industrial 2 of 5 Length Control

This feature specifies either variable length decoding or fixed length decoding for the Industrial 

2 of 5 symbology.

Variable Length: 

For variable length decoding, a minimum and maximum length may be set.

Fixed Length: 

For fixed length decoding, two different lengths may be set.

DEFAULT

$CU2LC00(CR)

Industrial 2 of 5 Length Control = Variable Length

$CU2LC01(CR)

Industrial 2 of 5 = Fixed Length

Содержание QuickScan QBT24 series

Страница 1: ...QuickScan I QD24XX QBT24XX QM24XX Product Reference Guide General Purpose Handheld Area Imager Bar Code Reader...

Страница 2: ...ces appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic version...

Страница 3: ...stem and Network Layouts 15 Connecting the Base when Security Pin is Enabled 15 Linking the Reader to a Base Station 16 Linking a BT Reader to a PC 16 Interface Selection 17 Setting the Interface 18 C...

Страница 4: ...Sets 58 Individually Set Label ID 59 Label ID Control 59 Label ID Symbology Selection 1D Symbologies 60 Advanced Formatting User Label Edit 65 Case Conversion 65 Character Conversion 66 Reading Parame...

Страница 5: ...EAN 13 Flag 1 Character 97 EAN 13 ISBN Conversion 97 EAN 13 2D Component 98 ISSN 98 ISSN Enable Disable 98 EAN 8 JAN 8 99 EAN 8 Enable Disable 99 EAN 8 Check Character Transmission 99 Expand EAN 8 to...

Страница 6: ...aracter Calculation 130 I 2 of 5 Check Character Transmission 131 I 2 of 5 Length Control 131 I 2 of 5 Set Length 1 132 I 2 of 5 Set Length 2 133 INTERLEAVED 2 OF 5 CIP HR 134 Interleaved 2 of 5 CIP H...

Страница 7: ...Expanded 2D Component 159 GS1 DataBar Expanded Length Control 160 GS1 DataBar Expanded Set Length 1 161 GS1 DataBar Expanded Set Length 2 162 GS1 DATABAR LIMITED 163 GS1 DataBar Limited Enable Disabl...

Страница 8: ...DF417 Length Control 194 PDF417 Set Length 1 195 PDF417 Set Length 2 196 Micro PDF417 197 Micro PDF417 Enable Disable 197 Micro PDF417 Code 128 GS1 128 Emulation 197 Micro PDF417 Length Control 198 Mi...

Страница 9: ...adio Transmit Mode 228 MESSAGE FORMATTING 229 Message Formatting 229 LED and Beeper Control 230 REFERENCES 231 RS 232 Parameters 232 RS 232 232 RS 232 USB COM Parameters 233 Keyboard Interface 240 Wed...

Страница 10: ...DEFAULTS 275 SAMPLE BAR CODES 287 KEYPAD 291 SCANCODE TABLES 293 Control Character Emulation 293 Single Press and Release Keys 293 Interface Type PC AT PS 2 USB Keyboard or USB Keyboard for APPLE 294...

Страница 11: ...reader There are different sections for interface types general features data formatting symbology specific and model specific features Chapter 4 Message Formatting gives background information and de...

Страница 12: ...tively printed copies or product support CDs for most products can be purchased through your Datalogic reseller Technical Support Datalogic Website Support The Datalogic website www datalogic com is t...

Страница 13: ...es It consists of a soft dark red illumination combined with two blue LED triangles pointing at the targeted bar code The result is a precise aiming system which contributes to low eye fatigue yet sti...

Страница 14: ...g Mode scan a number of parameter settings before scanning the ENTER EXIT bar code a second time which will then accept your changes exit Programming Mode and return the reader to normal operation The...

Страница 15: ...ase as well as battery charging sta tus as shown Figure 1 QuickScan Base LEDs Yellow LED Red LED Green LED LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and com...

Страница 16: ...g any device except for the scanner When the battery is used in devices other than the designated product it may damage the battery or reduce its life expectancy If the device causes an abnormal curre...

Страница 17: ...tteries separately from the device in compliance with European Directive 2006 66 EC 2011 65 EU 2002 96 EC and 2012 19 EU and subsequent modifica tions US and China regulatory and others laws and regul...

Страница 18: ...n gaged The battery pack will rise slightly in the rear pushed by the contact springs 2 Extract the battery pack by slightly rotating the pack and pulling away from the reader To mount the new battery...

Страница 19: ...pping container Setting Up the Reader Depending on whether you are using a Corded or Wireless version of the QuickScan follow the steps provided in this section to connect and get your reader up and c...

Страница 20: ...onnect disconnect the cable RS 232 Serial Connection Turn off power to the terminal PC and connect the reader to the terminal PC serial port via the RS 232 cable as shown in Figure 3 If the terminal w...

Страница 21: ...the keyboard and the remaining end at the keyboard port at the terminal PC Reference Figure 4 Figure 4 Keyboard Wedge Interface connection USB Connection Connect the reader to a USB port on the termin...

Страница 22: ...When the base is powered from the Host it automati cally selects a slow charge rate Configuring the Base Station Connecting the Base Station Figure 7 on page 14 shows how to connect the Base Station...

Страница 23: ...Base Station 2 Securely plug the Power Cable and Interface I F Cable connectors into their respective ports in the underside of the Base Station Cable Stopper Power Cable I F Cable 3 After the cables...

Страница 24: ...ug directly into the host device as shown in Figure 8 Keyboard Wedge interface cables have a Y connection where its female end mates with the male end of the cable from the keyboard and the remaining...

Страница 25: ...order shown 1 Power down the host system 2 Connect the appropriate interface cable into the Base as shown 3 Place the reader in the Base 4 Power up the host The reader will link to the Base 5 When th...

Страница 26: ...no Base Station was discovered Two green LED flashes after this tone indicates that more than one Base Station was discovered and the reader did not link Three LED flashes after this tone indicate a s...

Страница 27: ...oth address can be found under Properties within in the Bluetooth setup menu The link label is a Code 128 function 3 label with the following format FN3 char LnkB 12 character Bluetooth address 4 Scan...

Страница 28: ...terfaces require the scanner to start in the disabled state when pow ered up If additional scanner configuration is desired while in this state pull the trigger and hold it for five seconds The scanne...

Страница 29: ...AT NK Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key P HA26 P CR Select KBD AT ALT P HA10 P CR Selec...

Страница 30: ...page 39 P HA16 P CR Select KBD IBM MB Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Keyboard Wedge for DIGITAL Terminals VT2xx VT3xx VT4xx P HA1B P CR Select KBD DIG VT P H...

Страница 31: ...ettings the following sections of this manual allow configuration of non interface specific settings you might require Data Format Data Format offers options to control the messages sent to the Host s...

Страница 32: ...either the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below Both labels restore the scanner configuration to the factory settings including the interfa...

Страница 33: ...Configuration RS 232 USB Com Interfaces on page 32 Keyboard Settings on page 39 Parameters common to all interface applications Data Format on page 53 gives options to control the messages sent to the...

Страница 34: ...entry string You can then start again at the beginning 4 Complete the programming sequence by scanning the ENTER EXIT PROGRAMMING bar code to exit Programming Mode For more detailed descriptions progr...

Страница 35: ...When set to ignore the reader will ignore all host commands except for those necessary for service mode flash programming mode keeping the interface active transmission of labels DEFAULT CIFIH00 CR Ho...

Страница 36: ...Enter Exit Programming Mode Global Interface Features 26 QuickScan I QD24XX QBT24XX QM24XX NOTES...

Страница 37: ...ming bar codes in this section if modifications to the standard RS 232 inter face settings are necessary to meet your system s requirements Additional settings which apply to both the RS 232 and USB i...

Страница 38: ...te See page 232 for information on this feature CR2BA00 CR Baud Rate 1200 CR2BA01 CR Baud Rate 2400 CR2BA02 CR Baud Rate 4800 CR2BA03 CR Baud Rate 9600 DEFAULT CR2BA04 CR Baud Rate 19 200 CR2BA05 CR B...

Страница 39: ...rface with devices requiring a 7 bit or 8 bit ASCII pro tocol for sending and receiving data CR2DA00 CR 7 Data Bits CR2DA01 CR 8 Data Bits DEFAULT Stop Bits Set the number of stop bits to match host d...

Страница 40: ...X QM24XX Parity This feature specifies parity required for sending and receiving data Select the parity type according to host device requirements See page 232 for more information DEFAULT CR2PA00 CR...

Страница 41: ...g Control DEFAULT CR2HC00 CR Handshaking Control RTS CR2HC01 CR Handshaking Control RTS CTS CR2HC02 CR Handshaking Control RTS XON XOFF CR2HC03 CR Handshaking Control RTS On CTS CR2HC04 CR Handshaking...

Страница 42: ...RACTER on page 35 ACK NAK TIMEOUT VALUE on page 36 ACK NAK RETRY COUNT on page 36 ACK NAK ERROR HANDLING on page 37 INDICATE TRANSMISSION FAILURE on page 37 DISABLE CHARACTER on page 38 ENABLE CHARACT...

Страница 43: ...R EXIT PROGRAM MING MODE bar code above then the bar code at left fol lowed by the digits from the Alphanumeric characters in Appendix D Keypad representing your desired char acter s End by scanning t...

Страница 44: ...sable DEFAULT CBPNF01 CR Beep On Not On File Enable ACK NAK Options This enables disables the ability of the reader to support the RS 232 ACK NAK protocol See page 234 for more information DEFAULT CR2...

Страница 45: ...icts with normal operation of these characters 8 bit data is not recognized when the option Data Bits on page 29 has been set as 7 Data Bits NAK Character This setting specifies an ASCII character or...

Страница 46: ...istake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms ACK NAK Retry Count This feature speci...

Страница 47: ...ror Handling Ignore Errors Detected CR2EH01 CR ACK NAK Error Handling Process Error as Valid ACK Charac ter CR2EH02 CR ACK NAK Error Handling Process Error as Valid NAK Character Indicate Transmission...

Страница 48: ...ge 238 for more information on setting this feature CR2DC Select Disable Character Setting DEFAULT 0x44 Disable Character is D Enable Character Specifies the value of the RS 232 host command used to e...

Страница 49: ...MLOCK on page 46 USB KEYBOARD SPEED on page 47 USB KEYBOARD NUMERIC KEYPAD on page 48 Use the programming bar codes in this chapter to select options for USB Keyboard and Wedge Interfaces Reference Ap...

Страница 50: ...y Mode U S CKBCO01 CR Country Mode Belgium CKBCO02 CR Country Mode Britain CKBCO11 CR Country Mode Croatia Supports only the interfaces listed in the Country Mode feature description Supports only the...

Страница 51: ...the Country Mode feature description CKBCO13 CR Country Mode French Canadian CKBCO05 CR Country Mode Germany Supports only the interfaces listed in the Country Mode feature description CKBCO0D CR Cou...

Страница 52: ...KBCO12 CR Country Mode Poland Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces listed in the Country Mode feature description CKBCO08 CR Country...

Страница 53: ...amming Mode Product Reference Guide 43 Country Mode continued CKBCO09 CR Country Mode Spain KBCO0A CR Country Mode Sweden CKBCO0B CR Country Mode Switzerland Supports only the interfaces listed in the...

Страница 54: ...ent as control character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control character Ctrl Shift special keys are located from 0x8...

Страница 55: ...NTER EXIT bar code again Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 0A Quiet Interval is 100 milliseconds I...

Страница 56: ...y when an alternate key encoding keyboard is selected DEFAULT CKBCL00 CR Caps Lock State Caps Lock OFF CKBCL01 CR Caps Lock State Caps Lock ON CKBCL02 CR Caps Lock State AUTO Caps Lock Enable Numlock...

Страница 57: ...fies the USB poll rate for a USB keyboard DEFAULT CKBSP01 CR USB Keyboard Speed 1ms CKBSP02 CR USB Keyboard Speed 2ms CKBSP03 CR USB Keyboard Speed 3ms CKBSP04 CR USB Keyboard Speed 4ms CKBSP05 CR USB...

Страница 58: ...CR USB Keyboard Speed 10ms Enter Exit Programming Mode 48 QuickScan I QD24XX QBT24XX QM24XX USB Keyboard Speed continued USB Keyboard Numeric Keypad This option Controls whether numeric characters wil...

Страница 59: ...or USB interfaces differ depending upon which host type the reader will be connected with Use the feature settings in this chapter to specifically configure for the USB OEM interface Other USB interfa...

Страница 60: ...ing to enable all devices to communicate Options are Table Top Scanner Handheld Scanner CIBUT00 CR USB OEM Device Usage Table Top Scanner CIBUT01 CR USB OEM Device Usage Handheld Scanner DEFAULT It ma...

Страница 61: ...ot con verted to Code 39 or verified to be valid for Code 39 Options are IBM Standard Format Send labels in standard IBM format Mixed IBM Standard and Code 39 Format Code 39 Format Translate the follo...

Страница 62: ...QuickScan I QD24XX QBT24XX QM24XX Interface Options DEFAULT CIFO101 CR Obey Scanner Configuration Host Commands CIFO102 CR Ignore Scanner Configuration Host Commands This feature provides for an inter...

Страница 63: ...l ID Symbology Selection 1D Symbolo gies on page 60 Label ID Symbology Selection 2D Symbolo gies on page 64 CASE CONVERSION starting on page 65 CHARACTER CONVERSION starting on page 66 CAUTION It is n...

Страница 64: ...n the ENTER EXIT PROGRAMMING MODE bar code above to place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix bar code fol lowed by the digits in hex from the Alphanumeric cha...

Страница 65: ...identifiers consist of three characters as follows A close brace character ASCII followed by A code character see some samples in the table below followed by A modifier character the modifier characte...

Страница 66: ...5 DATA MATRIX d 64 EAN128 C 43 EAN128 COMPOSITE C 43 EAN13 E 45 EAN13 P2 E 45 EAN13 P5 E 45 EAN13 COMPOSITE E 45 EAN8 E 45 EAN8 P2 E 45 EAN8 P5 E 45 EAN8 COMPOSITE E 45 FOLLET 2OF5 X 58 I2OF5 I 49 IAT...

Страница 67: ...ctions on setting this feature CU8AI00 CR Set AIM ID Individually for GS1 128 Disable CU8AI01 CR Set AIM ID Individually for GS1 128 Enable DEFAULT POSTAL IMB X 58 POSTAL JAPANESE X 58 POSTAL KIX X 58...

Страница 68: ...ram the reader to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 55 See Label ID starting on page 247 of References for mor...

Страница 69: ...ing on page 60 to select the symbology you want to set followed by up to 3 characters from the ASCII Chart at the back of this manual See Label ID Set Individually Per Symbology on page 250 for detail...

Страница 70: ...g Mode Set ABC Codabar Label ID Character s CP3ID Set Code 32 Pharmacode Label ID Character s CALID Set Anker Plessey Label ID Character s CC9ID Set Code 93 Label ID Character s CPAID Set Australian P...

Страница 71: ...site Label ID Character s CU8ID Set GS1 128 Label ID Character s C82ID Set EAN 8 P2 Label ID Character s CUMID Set GS1 128 Composite Label ID Character s C85ID Set EAN 8 P5 Label ID Character s CLBID...

Страница 72: ...IMB Postal Code Label ID Character s CMSID Set MSI Label ID Character s CU2ID Set Industrial 2 of 5 Label ID Character s CPPID Set Planet Postal Code Label ID Character s CI2ID Set Interleaved 2 of 5...

Страница 73: ...haracter s CPRID Set Royal Postal Code Label ID Character s CA2ID Set UPC A P2 Label ID Character s CS2ID Set Standard 2 of 5 Label ID Character s CA5ID Set UPC A P5 Label ID Character s CPSID Set Swe...

Страница 74: ...er s CP4ID Set PDF 417 Label ID Character s CDMID Set Data Matrix Label ID Character s CMIID Set Micro PDF 417 Label ID Character s CMQID Set Micro QR Label ID Character s CQRID Set QR Code Label ID C...

Страница 75: ...on or contact Technical Support Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case DEFAULT CLFCA00 CR Case Conversion Disable no case conver...

Страница 76: ...haracter in the pair is the character that will be converted The second character in the pair is the character to convert to If the character to convert in a pair is FF then no conversion is done CLFC...

Страница 77: ...76 Stand Operation on page 77 Pick Mode on page 78 Stand Mode Sensitivity on page 78 Stand Mode Illumination Off Time on page 79 Scanning Active Time on page 79 Stand Illumination Control on page 80 F...

Страница 78: ...e same label again within the specified timeout the second read is ignored Double Read Timeout does not apply to scan modes that require a trigger pull for each label read CSNDR0A CR Double Read Timeo...

Страница 79: ...ters Enter Exit Programming Mode Product Reference Guide 69 Double Read Timeout continued CSNDR50 CR Double Read Timeout 0 8 Second CSNDR5A CR Double Read Timeout 0 9 Second CSNDR64 CR Double Read Tim...

Страница 80: ...PU00 CR Power On Alert Disable No Audible Indication CBPPU01 CR Power On Alert Power up Beep DEFAULT Good Read When to Indicate This feature specifies when the reader will provide indication beep and...

Страница 81: ...PTY00 CR Good Read Beep Type Mono CBPTY01 CR Good Read Beep Type Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the l...

Страница 82: ...d Read Beep Length 60 msec CBPLE08 CR Good Read Beep Length 80 msec DEFAULT CBPLE0A CR Good Read Beep Length 100 msec CBPLE0C CR Good Read Beep Length 120 msec CBPLE0E CR Good Read Beep Length 140 mse...

Страница 83: ...Read Beep Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels CBPVO00CR Good Read Beep Volume Beeper Off CBPVO01CR Good Read Beep Volume Low CBPVO...

Страница 84: ...instructions and examples for setting this feature CLAGL00 CR Good Read LED Duration Setting Keep LED on until next trigger pull CLAGL Select Good Read LED Duration Setting To configure this feature s...

Страница 85: ...254 in References for descriptions CSNRM00 CR Scan Mode Trigger Single DEFAULT CSNRM01 CR Scan Mode Trigger Hold Multiple CSNRM02 CR Scan Mode Trigger Pulse Multiple CSN Scan Mode Flashing CSNRM04 CR...

Страница 86: ...tand Mode If enabled the blue indicator will blink when Stand Mode scanning is active If the reader is removed from its Stand support or from the Base Station cordless models and switches out of Stand...

Страница 87: ...ase station cordless models only Below are further options concerning Stand Operation Ignore Autorecognition Disables mode switching when the reader is placed in a stand Change to Stand Mode Automatic...

Страница 88: ...y target labels when they are placed close together such as on a pick sheet This feature is not compatible with Multiple Labels Reading in a Volume DEFAULT CSNPM00 CR Pick Mode Disable CSNPM01 CR Pick...

Страница 89: ...GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix D Keypad representing your desired character s End by scanning the ENTER EX...

Страница 90: ...Mode The selectable range is 100 to 9 900 milliseconds 0 1 to 9 9 seconds in 100 millisecond increments See page 258 in References for detailed information on setting this feature CSNFN Select Flash O...

Страница 91: ...g To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix D Keypad representing yo...

Страница 92: ...257 in References for a description of this feature DEFAULT LSTM00 Aiming Off After Decoding LSTM Set Aiming Duration Timer To configure scan the ENTER EXIT PROGRAMMING MODE bar code above then the b...

Страница 93: ...t is Off CLSSP01 CR Green Spot Duration Short 300 msec DEFAULT CLSSP02 CR Green Spot Duration Medium 500 msec CLSSP03 CR Green Spot Duration Long 800 msec Mobile Phone Mode This mode is useful for sca...

Страница 94: ...labels in this man ual Scan the Disable bar code below to return the scanner to its default for this feature To set decoding for only 2D codes go to 2D Normal Inverse Symbol Control on page 181 For a...

Страница 95: ...bels are present in the volume only the first label encountered is decoded and sent When Multiple Reading Mode is enabled the scanner keeps on processing the image until all the labels present are dec...

Страница 96: ...RAMMING MODE bar code above then the bar code at left followed by the digits From the alphanumeric char acters In Appendix d keypad representing your desired Character s end by scanning the enter exit...

Страница 97: ...93 page 164 Code 39 PZN page 119 MSI page 169 Code 128 page 120 Plessey page 174 Default settings are indicated at each feature option with a green arrow Also reference Appendix B Standard Defaults f...

Страница 98: ...IES Use this feature to disable all symbologies 1 Scan the ENTER EXIT PROGRAMMING Mode bar code 2 Scan the Disable All Symbologies bar code 3 Complete the programming sequence by scanning the ENTER EX...

Страница 99: ...Control This feature is used to control the reader s method of processing coupon labels CCPLC00 CR Coupon Control Allow all coupon bar codes to be decoded CCPLC01 CR Coupon Control Enable only UPCA c...

Страница 100: ...sable When disabled the reader will not read UPC A bar codes CABEN00 CR UPC A Disable CABEN01 CR UPC A Enable DEFAULT UPC A Check Character Transmission Enable this option to transmit the check charac...

Страница 101: ...the sym bology ID to match those required for EAN 13 DEFAULT CAB3B00 CR UPC A to EAN 13 Don t Expand CAB3B01 CR UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables...

Страница 102: ...when a base label of this symbology is decoded DEFAULT CAB2D00 CR EAN 13 2D Component Disable 2D component not required CAB2D01 CR EAN 13 2D Component 2D component must be decoded UPC E The following...

Страница 103: ...T00 CR UPC E Check Character Transmission Don t Send CEBCT01 CR UPC E Check Character Transmission Send DEFAULT UPC E 2D Component This feature enables disables a requirement that a 2D label component...

Страница 104: ...ata format Selecting this feature also changes the sym bology ID to match those required for EAN 13 DEFAULT CEB3B00 CR UPC E to EAN 13 Don t Expand CEB3B01 CR UPC E to EAN 13 Expand Expand UPC E to UP...

Страница 105: ...transmit CEBNS01 CR UPC E Number System Character Transmit DEFAULT GTIN FORMATTING This feature enables disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character...

Страница 106: ...Disable When disabled the reader will not read EAN 13 JAN 13 bar codes C3BEN00 CR EAN 13 Disable C3BEN01 CR EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the...

Страница 107: ...character is the first character of the label C3BF100 CR EAN 13 Flag 1 Char Don t transmit C3BF101 CR EAN 13 Flag 1 Char Transmit DEFAULT EAN 13 ISBN Conversion This option enables disables conversion...

Страница 108: ...bel of this symbology is decoded DEFAULT C3B2D00 CR EAN 13 2D Component Disable 2D component not required C3B2D01 CR EAN 13 2D Component 2D component must be decoded ISSN The following options apply t...

Страница 109: ...able When disabled the reader will not read EAN 8 JAN 8 bar codes C8BEN00 CR EAN 8 Disable C8BEN01 CR EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check c...

Страница 110: ...FAULT C8B3B00 CR Expand EAN 8 to EAN 13 Disable C8B3B01 CR Expand EAN 8 to EAN 13 Enable EAN 8 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base...

Страница 111: ...or each feature description UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits DEFAULT CPWEN00 CR Price Weight Check Disabled CPWEN01 CR...

Страница 112: ...number of quiet zones for UPC EAN labels Quiet zones are blank areas at the ends of a bar code typically 10 times the width of the narrowest bar or space in the label The property applies to all EAN U...

Страница 113: ...Add Ons Enable P2 DEFAULT CADO500 CR Optional Add Ons Disable P5 CADO501 CR Optional Add Ons Enable P5 Cordless models only DEFAULT CADO800 CR Optional Add Ons Disable GS1 128 CADO801 CR Optional Add...

Страница 114: ...ill look for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 107 CADOT01 CR Optional Add on Timer 10ms CADOT02 CR Option...

Страница 115: ...70ms DEFAULT CADOT0A CR Optional Add on Timer 100ms CADOT0C CR Optional Add on Timer 120ms CADOT0E CR Optional Add on Timer 140ms CADOT10 CR Optional Add on Timer 160ms 1D Symbologies Enter Exit Progr...

Страница 116: ...Optional Add on Timer 220ms CADOT18 CR Optional Add on Timer 240ms CADOT1A CR Optional Add on Timer 260ms CADOT1C CR Optional Add on Timer 280ms CADOT1E CR Optional Add on Timer 300ms Enter Exit Progr...

Страница 117: ...ar EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 104 DEFAULT CADUT00 CR Optional GS1 128 Add On Timer Disable CADUT01 CR Optional GS1 128 Add On Time...

Страница 118: ...T0A CR Optional GS1 128 Add On Timer 100ms CADUT0C CR Optional GS1 128 Add On Timer 120ms CADUT0E CR Optional GS1 128 Add On Timer 140ms CADUT10 CR Optional GS1 128 Add On Timer 160ms Enter Exit Progr...

Страница 119: ...28 Add On Timer 220ms CADUT18 CR Optional GS1 128 Add On Timer 240ms CADUT1A CR Optional GS1 128 Add On Timer 260ms CADUT1C CR Optional GS1 128 Add On Timer 280ms CADUT1E CR Optional GS1 128 Add On Ti...

Страница 120: ...39 Check Character Calculation Enable this option to enables disables calculation and verification of an optional Code 39 check character When disabled any check character in the label is treated as...

Страница 121: ...cter along with Code 39 bar code data CC3CT00 CR Code 39 Check Character Transmission Don t Send CC3CT01 CR Code 39 Check Character Transmission Send DEFAULT Code 39 Check Character Calculation contin...

Страница 122: ...of Code 39 start and stop characters DEFAULT CC3SS00 CR Code 39 Start Stop Character Transmission Don t Transmit CC3SS01 CR Code 39 Start Stop Character Transmission Transmit Code 39 Full ASCII Enabl...

Страница 123: ...39 Quiet Zones Quiet Zones on two sides CC3LO03 CR Code 39 Quiet Zones Small Quiet Zones on two sides DEFAULT Code 39 Length Control This feature specifies either variable length decoding or fixed len...

Страница 124: ...rovides examples for setting Length 1 See page 243 for detailed instructions on set ting this feature Table 3 Code 39 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07...

Страница 125: ...Table 4 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 4 Code 39 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignor...

Страница 126: ...ptic Code Enable Disable DEFAULT CCTEN00 CR Trioptic Code Disable CCTEN01 CR Trioptic Code Enable CODE 32 ITAL PHARMACEUTICAL CODE The following options apply to the Code 32 Italian Pharmaceutical Cod...

Страница 127: ...eck Char Transmission Enable this option to transmit the check character along with Code 32 bar code data DEFAULT CP3CT00 CR Code 32 Check Character Transmission Don t Send CP3CT01 CR Code 32 Check Ch...

Страница 128: ...nable Disable Enables Disables ability of the reader to decode Code 39 CIP labels DEFAULT CCCEN00 CR Code 39 CIP Disable CCCEN01 CR Code 39 CIP Enable CODE 39 DANISH PPT The following options apply to...

Страница 129: ...es disables the ability of the scanner to decode Code39 La Poste labels DEFAULT CLPEN00 CR Code 39 LaPoste Disable CLPEN01 CR Code 39 LaPoste Enable CODE 39 PZN The following options apply to the Code...

Страница 130: ...Code 128 Enable Disable When disabled the reader will not read Code 128 bar codes CC8EN00 CR Code 128 Disable CC8EN01 CR Code 128 Enable DEFAULT Expand Code 128 to Code 39 This feature enables disable...

Страница 131: ...bar code data DEFAULT CC8CT00 CR Code 128 Check Character Transmission Don t Send CC8CT01 CR Code 128 Check Character Transmission Send Code 128 Function Character Transmission Enables disables trans...

Страница 132: ...width of the narrowest bar or space in the label CC8LO02 CR Code 128 Quiet Zones Quiet Zones on two sides CC8LO03 CR Code 128 Quiet Zones Small Quiet Zones on two sides DEFAULT Code 128 Length Contro...

Страница 133: ...me examples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 5 Code 128 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Charac...

Страница 134: ...h only one fixed length Table 6 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 6 Code 128 Length 2 Setting Examples STEP ACTION EXAMPLES 1...

Страница 135: ...e Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels CU8EN00CR GS1 128 Transmit in Code 128 data format CU8EN01CR GS1 128 Tra...

Страница 136: ...disable ISBT128 concatenation of 2 labels DEFAULT CI8CE00 CR ISBN 128 Concatenation Disable CI8CE01 CR ISBN 128 Concatenation Enable ISBT 128 Force Concatenation When enabled this feature forces conca...

Страница 137: ...oncatenation Mode Specifies the concatenation mode between Static and Dynamic DEFAULT CI8CM00CR ISBT 128 Concatenation Mode Static CI8CM01CR ISBT 128 Concatenation Mode Dynamic This option is only val...

Страница 138: ...tenation Mode CI8DT05 CR ISBT 128 Dynamic Concatenation Timeout 50 msec CI8DT0A CR ISBT 128 Dynamic Concatenation Timeout 100 msec DEFAULT CI8DT14 CR ISBT 128 Dynamic Concatenation Timeout 200 msec CI...

Страница 139: ...tenation use the Datalogic Aladdin configura tion application or contact Datalogic Technical Support as described on page 2 INTERLEAVED 2 OF 5 I 2 OF 5 The following options apply to the I 2 of 5 symb...

Страница 140: ...configuration utility or contact Technical Support DEFAULT CI2CC00 CR I 2 of 5 Check Character Calculation Disable CI2CC01 CR I 2 of 5 Check Character Calculation Check Standard Modulo 10 CI2CC02 CR I...

Страница 141: ...I2CT01 CR I 2 of 5 Check Character Transmission Send DEFAULT I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology Variable...

Страница 142: ...mples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 7 I 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14...

Страница 143: ...able 8 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 8 I 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore T...

Страница 144: ...Disable Enables Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels DEFAULT CCHEN00 CR Interleaved 2 of 5 CIP HR Disable CCHEN01 CR Interleaved 2 of 5 CIP HR Enable FOLLETT 2 OF 5 Th...

Страница 145: ...er will not read Standard 2 of 5 bar codes DEFAULT CS2EN00 CR Standard 2 of 5 Disable CS2EN01 CR Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation This option enables disables calcula...

Страница 146: ...T01 CR Standard 2 of 5 Check Character Transmission Send DEFAULT Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5...

Страница 147: ...some examples for setting Length 1 See page 243 if you want detailed instructions on setting this feature Table 9 Standard 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 C...

Страница 148: ...fixed length Table 10 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 10 Standard 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 D...

Страница 149: ...ty of reader to decode Industrial 2 of 5 labels DEFAULT CU2EN00 CR Industrial 2 of 5 Disable CU2EN01 CR Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculat...

Страница 150: ...Industrial 2 of 5 Check Character Transmission Enable DEFAULT Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5...

Страница 151: ...examples for setting Length 1 See page 243 if you want detailed instructions on setting this feature Table 11 Industrial 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Cha...

Страница 152: ...of 0 specifies to ignore this length only one fixed length Table 12 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 12 Industrial 2 of 5 Le...

Страница 153: ...es Disables the ability of the reader to decode IATA labels DEFAULT CIAEN00 CR IATA Disable CIAEN01 CR IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an...

Страница 154: ...Codabar Enable Codabar Check Character Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the...

Страница 155: ...a CCBCT00 CR Codabar Check Character Transmission Don t Send CCBCT01 CR Codabar Check Character Transmission Send DEFAULT Codabar Start Stop Character Transmission Enable this option to enable disable...

Страница 156: ...acter Set ABCD TN E CCBSC01 CR Codabar Check Character Set ABCD ABCD CCBSC02 CR Codabar Check Character Set abcd tn e CCBSC03 CR Codabar Check Character Set abcd abcd DEFAULT Codabar Start Stop Charac...

Страница 157: ...Quiet Zones Quiet Zones on two sides CCBLO03 CR Codabar Quiet Zones Small Quiet Zones on two sides DEFAULT Codabar Length Control This feature specifies either variable length decoding or fixed lengt...

Страница 158: ...et from 3 to 50 characters Table 13 provides some examples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 13 Codabar Length 1 Setting Examples STEP ACTION EX...

Страница 159: ...of 0 specifies to ignore this length only one fixed length Table 14 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 14 Codabar Length 2 Se...

Страница 160: ...odabar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels DEFAULT CCBAB00 CR ABC Codabar Disable CCBAB01 CR ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the...

Страница 161: ...catenation Mode CCBDT05 CR ABC Codabar Dynamic Concatenation Timeout 50 msec CCBDT0A CR ABC Codabar Dynamic Concatenation Timeout 100 msec DEFAULT CCBDT14 CR ABC Codabar Dynamic Concatenation Timeout...

Страница 162: ...152 QuickScan I QD24XX QBT24XX QM24XX ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated DEFAULT CCBFC00 CR ABC Codabar Force Concatenation Disable CCBFC01 CR...

Страница 163: ...T CC1EN00 CR Code 11 Disable CC1EN01 CR Code 11 Enable Code 11 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character CC1CC00 CR Code...

Страница 164: ...CC1CT01 CR Code 11 Check Character Transmission Send DEFAULT Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology Variable L...

Страница 165: ...examples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 15 Code 11 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading zeroes 0...

Страница 166: ...fixed length Table 16 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 16 Code 11 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired S...

Страница 167: ...e reader will not read GS1 DataBar Omnidirectional bar codes DEFAULT C4BEN00 CR GS1 DataBar Omnidirectional Disable C4BEN01 CR GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Em...

Страница 168: ...B2D00 CR GS1 DataBar Omnidirectional 2D Component Disable 2D component not required C4B2D01 CR GS1 DataBar Omnidirectional 2D Component 2D component must be decoded GS1 DATABAR EXPANDED The following...

Страница 169: ...mat DEFAULT CXBU800 CR GS1 DataBar Expanded GS1 128 Emulation Disable CXBU801 CR GS1 DataBar Expanded GS1 128 Emulation Enable GS1 DataBar Expanded 2D Component This feature enables disables a require...

Страница 170: ...le length decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two d...

Страница 171: ...ome examples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 17 GS1 DataBar Expanded Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Chara...

Страница 172: ...ly one fixed length Table 18 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 18 GS1 DataBar Expanded Length 2 Setting Examples STEP ACTION...

Страница 173: ...e When disabled the reader will not read GS1 DataBar Limited bar codes DEFAULT CLBEN00 CR GS1 DataBar Limited Disable CLBEN01 CR GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When e...

Страница 174: ...label of this symbology is decoded DEFAULT CLB2D00 CR GS1 DataBar Limited 2D Component Disable 2D component not required CLB2D01 CR GS1 DataBar Limited 2D Component 2D component must be decoded CODE...

Страница 175: ...on Disable CC9CC01 CR Code 93 Check Character Calculation Enable Check C CC9CC02 CR Code 93 Check Character Calculation Enable Check K CC9CC03 CR Code 93 Check Character Calculation Enable Check C and...

Страница 176: ...r variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decodin...

Страница 177: ...ome examples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 19 Code 93 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Char...

Страница 178: ...f 0 specifies to ignore this length only one fixed length Table 20 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 20 CODE 93 Length 2 Sett...

Страница 179: ...for Code 93 CC9LO02 CR Code 93 Quiet Zones Quiet Zones on two sides CC9LO03 CR Code 93 Quiet Zones Small Quiet Zones on two sides DEFAULT MSI The following options apply to the MSI symbology MSI Enab...

Страница 180: ...acter Calculation Disable CMSCC01 CR MSI Check Character Calculation Enable Mod10 DEFAULT CMSCC02 CR MSI Check Character Calculation Enable Mod11 10 CMSCC03 CR MSI Check Character Calculation Enable M...

Страница 181: ...her variable length decoding or fixed length decoding for the MSI sym bology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding...

Страница 182: ...ovides some examples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 21 MSI Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07...

Страница 183: ...of 0 specifies to ignore this length only one fixed length Table 22 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 22 MSI Length 2 Setting...

Страница 184: ...ey Enable Plessey Check Character Calculation Enables Disables calculation and verification of an optional Plessey check character CPLCC00 CR Plessey Check Character Calculation Disable CPLCC01 CR Ple...

Страница 185: ...R Plessey Check Character Transmission Enable DEFAULT Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology Variable Length F...

Страница 186: ...ovides some examples for setting Length 1 See page 243 for detailed instructions on setting this feature Table 23 Plessey Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters...

Страница 187: ...0 specifies to ignore this length only one fixed length Table 24 provides examples for setting Length 2 See page 243 for detailed instructions on set ting this feature Table 24 Plessey Length 2 Setti...

Страница 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...

Страница 189: ...a green arrow Also reference Appendix B Standard Defaults for a listing of the most widely used set of standard factory set tings That section also provides space to record any custom settings needed...

Страница 190: ...bel The selectable range is 10 milliseconds to 2 55 milliseconds CDETM0A CR 2D Maximum Decoding Time 100 msec CDETM32 CR 2D Maximum Decoding Time 200 msec CDETM23 CR 2D Maximum Decoding Time 350 msec...

Страница 191: ...Append Enable 2D Normal Inverse Symbol Control Specifies the options available for decoding normal negative printed 2D symbols This configu ration item applies globally to all the 2D symbologies that...

Страница 192: ...able CAZEN01 CR Aztec Code Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length deco...

Страница 193: ...of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CAZL1 Select Aztec Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar cod...

Страница 194: ...s of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CAZL2 Select Aztec Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar co...

Страница 195: ...CCSEN01 CR China Sensible Code Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variabl...

Страница 196: ...of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CCSL1 Select China Sensible Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE...

Страница 197: ...incre ments of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CCSL2 Select China Sensible Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO...

Страница 198: ...options available when reading Data Matrix with different form factors Choices are Square Style Rectangular Style Both Square and Rectangular Style The configuration item can also be configured as a b...

Страница 199: ...Control on page 189 Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 3 116 characters in increments...

Страница 200: ...ts of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CDML2 Select Data Matrix Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar...

Страница 201: ...ecode Maxicode labels DEFAULT CMXEN00 CR Maxicode Disable CMXEN01 CR Maxicode Enable Maxicode Primary Message Transmission Enables disables the transmission of only the Primary Message when the Second...

Страница 202: ...page 192 Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 0145 characters in increments of 0001 pad...

Страница 203: ...ements of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CMXL2 Select Maxicode Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar...

Страница 204: ...F417 Enable DEFAULT PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length decoding a minimum and...

Страница 205: ...increments of 01 Any value greater than 2 710 will be considered to be 2 710 See page 243 for detailed instructions on setting this feature CP4L1 Select PDF417 Length 1 Setting To configure this feat...

Страница 206: ...o 2 710 characters pad with zeroes in increments of 01 Any value greater than 2 710 will be consid ered to be 2 710 See page 243 for detailed instructions on setting this feature CP4L2 Select PDF417 L...

Страница 207: ...IEN01 CR Micro PDF417 Enable Micro PDF417 Code 128 GS1 128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1 128 emulation Emulation choices are Micro PDF AIM ID a...

Страница 208: ...if in Variable Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only Characters can be set from 0001 to 0366 characters pad with zeroes in i...

Страница 209: ...es in increments of 01 Any value greater than 0366 will be considered to be 0366 See page 243 for detailed instructions on setting this feature CMIL2 Select Micro PDF417 Length 2 Setting To configure...

Страница 210: ...Code Enable DEFAULT QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length decoding a minimum a...

Страница 211: ...f 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CQRL1 Select QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code abo...

Страница 212: ...of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CQRL2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code a...

Страница 213: ...MQEN01 Micro QR Code Enable Micro QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbol ogy Variable Length For variable length decodin...

Страница 214: ...001 pad with zeroes See page 243 for detailed instructions on setting this feature CMQL1 Select Micro QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code...

Страница 215: ...incre ments of 0001 pad with zeroes See page 243 for detailed instructions on setting this feature CMQL2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PRO GRAMMING MODE...

Страница 216: ...Composite Enable Disable Enables disables the ability of the reader to decode the stacked part of a UCC Composite label DEFAULT CCMEN00 CR UCC Composite Disable CCMEN01 CR UCC Composite Enable This fe...

Страница 217: ...fore transmitting the linear label without an add on DEFAULT CCMOT00 CR UCC Optional Composite Timer Timer Disabled CCMOT01 CR UCC Optional Composite Timer 100msec CCMOT02 CR UCC Optional Composite Ti...

Страница 218: ...Australia Post Postnet Japan Post Planet IMB Royal Mail Sweden Post Kix Portugal Post DEFAULT CPOEN00 CR Postal Code Selection Disable All Postal Codes CPOEN01 CR Postal Code Selection Enable Postnet...

Страница 219: ...Postal Code Selection Enable IMB CPOEN08 CR Postal Code Selection Enable Sweden Post CPOEN09 CR Postal Code Selection Enable Portugal Post Postnet BB Control Controls the ability of the scanner to de...

Страница 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...

Страница 221: ...o Scanner on page 217 Copy Configuration to Base Station on page 218 BATCH FEATURES starting on page 218 Batch Mode on page 218 Send Batch on page 219 Erase Batch Memory on page 219 RF Batch Mode Tran...

Страница 222: ...on Beep indication When enabled a beep occurs when a Label is correctly transmitted to the base CBTAB00 CR Good Transmission Beep Disable CBTAB01 CR Good Transmission Beep Enable DEFAULT Beep Frequenc...

Страница 223: ...tion of radio specific beep indications CBTBD06 CR Beep Duration 60 msec CBTBD08 CR Beep Duration 80 msec DEFAULT CBTBD0A CR Beep Duration 100 msec CBTBD0C CR Beep Duration 120 msec CBTBD0E CR Beep Du...

Страница 224: ...three select able volume levels CBTBV00 CR Beep Volume Low CBTBV01 CR Beep Volume Medium CBTBV02 CR Beep Volume High DEFAULT Disconnect Beep Enables disables the beep indication that a handheld has b...

Страница 225: ...ee per second when the handheld goes out of range This is especially useful in instances where the reader might inadvertently have been placed in a bag or cart For this mode to be effective the reader...

Страница 226: ...QuickScan I QD24XX QBT24XX QM24XX Leash Alarm continued CBTLB03 CR Leash Alarm 3 Seconds CBTLB04 CR Leash Alarm 4 Seconds CBTLB05 CR Leash Alarm 5 Seconds CBTLB0A CR Leash Alarm 10 Seconds CBTLB19 CR...

Страница 227: ...plication hardware and or configuration CBTCU00 CR Automatic Configuration Update Disable CBTCU01 CR Automatic Configuration Update Enable DEFAULT Copy Configuration to Scanner Scan the following labe...

Страница 228: ...T PROGRAMMING MODE label with this bar code BATCH FEATURES Batch Mode This option specifies whether to store labels in the handheld while disconnected from the base Options are as follows Disabled The...

Страница 229: ...ase Batch Memory When the scanner is configured in Manual Batch Mode use the following bar code to erase any labels stored in batch memory BatchClear Erase Batch Memory Do not scan an ENTER EXIT PROGR...

Страница 230: ...s handheld to a base station without scanning the Unlink label first DEFAULT CBTDL00 CR Direct Radio Link Unlink Label Required CBTDL01 CR Direct Radio Link Automatic Unlinking RF Batch Mode Transmit...

Страница 231: ...es disables the ability of source radio address information to be transmitted to the host and if so at what position with respect to the label data See page 262 in References for detailed information...

Страница 232: ...an then start again at the beginning CANCEL DEFAULT 00 No Delimiter Character This feature only applies if Source Radio Address Transmission on page 221 is enabled Link Timeout This feature specifies...

Страница 233: ...code in Select PIN Code Length on page 224 3 Scan the relevant bar code from Set PIN Code on page 224 then scan the desired alpha numeric characters from the keypad in Appendix D Keypad to set the PIN...

Страница 234: ...hen convert to hexadecimal using the ASCII Chart on page 1 on the inside back cover of this manual See page 264 for detailed information and examples for setting this feature CBTPC Set 4 character BT...

Страница 235: ...HER BT FEATURES BT Poll Rate This feature specifies the time between BT polls CBTST00 CR BT Poll Rate Maximum BT Poll Rate CBTST01 CR BT Poll Rate 10 ms CBTST02 CR BT Poll Rate 20 ms DEFAULT CBTST05 C...

Страница 236: ...owerdown Timeout feature sets the time for automatically switching the unit off when the imager has been idle CSLPS00 CR Powerdown Timeout Disable CSLPS01 CR Powerdown Timeout 10 minutes CSLPS02 CR Po...

Страница 237: ...between the handheld reader and Base Station is considered failed When setting this parameter take into consideration the radio traffic number of readers in the same area The selectable range for thi...

Страница 238: ...el to the host ACK from host scanner signals a good transmission as soon as the Base Station has sent the label to the host and host has replied with an acknowledge message DEFAULT ACK from cradle ACK...

Страница 239: ...or Service mode command Base station can receive host message only if Host Commands Obey Ignore is set to Ignore Message could be sent to the HH in response to a Label when Transmit mode require Ack f...

Страница 240: ...off the green spot ESC 0 r Beep for Find me function new ESC 1 r Power off new The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combinati...

Страница 241: ...RS 232 RS 232 USB COM Parameters KEYBOARD INTERFACE starting on page 240 Wedge Quiet Interval Intercharacter Delay Intercode Delay DATA EDITING starting on page 244 Global Prefix Suffix Global AIM ID...

Страница 242: ...parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1...

Страница 243: ...DELAY SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the l...

Страница 244: ...these characters 8 bit data is not recognized when the option Data Bits has been set as 7 Data Bits 1 Determine the desired character or value 2 Use the ASCII Chart on the inside back cover of this m...

Страница 245: ...35 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from the keypad in A...

Страница 246: ...UE SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last...

Страница 247: ...ad in Appendix D Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character s...

Страница 248: ...Go to page 38 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT DISABLE CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from...

Страница 249: ...red character value 3 Go to page 38 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT ENABLE CHARACTER SETTING 5 Scan the appropriate two alphanum...

Страница 250: ...Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character I...

Страница 251: ...ACTER DELAY SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after...

Страница 252: ...that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan the CANCEL bar cod...

Страница 253: ...for your selected symbology 4 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the length setting which was determined in the steps above You will hear a two beep in...

Страница 254: ...led a message string The Data Editing features can be used to build specific user defined data into a message string There are several types of selectable data characters that can be sent before and a...

Страница 255: ...Prefix Suffix AIM ID Label ID Label ID Bar Code Data 00 20 Characters ASCII AND OR OR Example Setting a Prefix In this example we ll set a prefix for all symbologies 1 Determine which ASCII character...

Страница 256: ...lows A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN Ea...

Страница 257: ...The reader supports two pre loaded sets of Label IDs Table 35 shows the USA and the EU sets CAUTION When changing from one Label ID set to another all other reader configuration settings including th...

Страница 258: ...13 P2 F 460000 L 4C0000 EAN13 P5 F 460000 M 4D0000 EAN13 COMPOSITE F 460000 F 244600 EAN8 FF 464600 A 410000 EAN8 P2 FF 464600 J 4A0000 EAN8 P5 FF 464600 K 4B0000 EAN8 COMPOSITE FF 464600 G 244700 FOL...

Страница 259: ...00 POSTAL PORTUGAL P 245000 P 245000 POSTAL POSTNET BB L 244C00 L 244C00 POSTAL ROYAL MAIL M 244D00 M 244D00 POSTAL SWEDISH X 245800 X 245800 POSTNET 1 310000 1 310000 QR CODE QR 515200 y 790000 S25 s...

Страница 260: ...lected symbology 5 Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal...

Страница 261: ...on page 60 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII Chart inside back cover then scan i...

Страница 262: ...abel AB12BA21 it would look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 char acters Nothing is done with...

Страница 263: ...de SELECT GOOD READ LED DURATION SETTING 5 Scan the appropriate three digits from the keypad in Appendix D Keypad representing the duration which was determined in the steps above You will hear a two...

Страница 264: ...anning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again Double Read Time out prevents undesired multiple reads of the same label while in this mode...

Страница 265: ...can the bar code Set Stand Mode Illuminator Off Time 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the setting which was determined in the steps above You will...

Страница 266: ...D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan the CANC...

Страница 267: ...D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan the CANC...

Страница 268: ...from the keypad in Appendix D Keypad representing the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the la...

Страница 269: ...the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last...

Страница 270: ...page 86 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING 5 Scan the appropriate two alphanumeric charact...

Страница 271: ...Reserved 3B LABELIMAGE 12 Reserved 3C CAPTURE_IMAGE_LABEL 13 CODE49 3D Reserved 14 UPC E2 3E M2OF5 15 UPC E5 3F D2OF5 16 Reserved 40 PLESSEY65 17 UPC A2 42 ISSN 18 UPC A5 43 ISBT 19 Reserved 44 Reserv...

Страница 272: ...desired character then find its hexadecimal equivalent on the ASCII Chart on the inside back cover A setting of 00 specifies no delimiter character 2 Go to page 222 and scan the ENTER EXIT PROGRAMMING...

Страница 273: ...5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character...

Страница 274: ...l hear a two beep indication after the last character If you make a mistake before the last character scan the CANCEL bar code to abort and not save the entry string You can then start again at the be...

Страница 275: ...140mA N A Operating max 380mA N A Idle standby typical 50mA N A Battery Type N A Li Ion battery pack Typical charge time for full charge from full discharge N A 6 hours with Host Power through the mi...

Страница 276: ...20 C label inclination 10 Symbology Code 39 5mil 0 2 5 9 0 5 15cm 10mil 0 8 7 0 22cm 20mil up to 16 40cm EAN 7 5mil 0 5 9 0 15cm 13mil 0 2 13 8 0 5 35cm PDF 417 6 6mil 0 39 5 1 1 0 130cm 10mil 0 8 3 0...

Страница 277: ...configurable for the following parameters Normal or Inverted Square or Rectangular Style Data length 1 3600 characters Maxicode QR Codes QR and Multiple QR Codes Aztec Postal Codes Australian Post Ja...

Страница 278: ...to concrete Ambient Light Immunity Up to 86 000 Lux Contaminants Spray Rain Dust Particulates IEC 529 IP42 IP51 QD2430 E model only ESD Level 16 KV Regulatory Electrical Safety UL 60950 CSA C22 2 No...

Страница 279: ...as they may vary from those depicted Scanner Regulatory Label CAUTION The QuickScan Handheld Reader is not user serviceable Opening the case of the unit can cause internal damage and will void the war...

Страница 280: ...information for the interface cable Figure 14 Standard Cable Pinouts Handheld Pin 10 Cable Clip Latch To Host Cable Cable Strain Relief Bottom of Scanner Interface Cable Port Pin 1 Figure 15 Standard...

Страница 281: ...ble Pinouts Handheld QD24XX model or Base Station QBT24XX and GM44XX Star models Side Pin RS 232 OEM USB Keyboard Wedge 1 RTS out 2 D CLKIN KBD side 3 D DATAIN KBD side 4 GND GND GND GND 5 RX 6 TX 7 V...

Страница 282: ...ce at cur rent frequency volume mono bi tonal setting and duration upon a successful label scan ROM Failure There is an error in the reader s software programming Flashes Reader sounds one error beep...

Страница 283: ...ng Mode Acceptance of Programming Configuration option s have been successfully programmed via labels and the reader has exited Programming Mode N A Reader sounds one high fre quency beep and 4 low fr...

Страница 284: ...ion alignment with the handheld is in prog ress Red LED blinks quickly Battery charging in progress Red LED on Battery charging complete Green LED on Battery charger error Green LED and Red LEDs blink...

Страница 285: ...efaults Parameter Default Your Setting Page Number GLOBAL INTERFACE FEATURES Host Commands Obey Ignore Obey 25 USB Suspend Mode Disable 25 RS 232 ONLY Baud Rate 9600 28 Data Bits 8 Data Bits 29 Stop B...

Страница 286: ...Handheld 50 USB Interface Options Ignore Scanner Configura tion Host Commands 50 DATA FORMAT Global Prefix Suffix No Global Prefix Global Suffix 0x0D CR 54 Global AIM ID Disable 55 Set AIM ID Individu...

Страница 287: ...Illumination Control OFF 80 Flash On Time 10 Flash is ON for 1 Sec ond 80 Flash Off Time 06 Flash is OFF for 600ms 81 Aiming Pointer Enable 81 Aiming Duration Timer Aiming Off After Decoding 82 Green...

Страница 288: ...heck Character Transmission Send 93 UPC E 2D Component 2D Component Not Required 93 Expand UPC E to EAN 13 Don t Expand 94 Expand UPC E to UPC A Don t Expand 94 UPC E Number System Character Transmiss...

Страница 289: ...110 Code 39 Check Character Calculation Disable 110 Code 39 Check Character Transmission Send 111 Code 39 Start Stop Character Trans mission Don t Transmit 112 Code 39 Full ASCII Disable 112 Code 39...

Страница 290: ...e 128 Function Character Trans mission Don t Send 121 Code 128 Quiet Zones Small Quiet Zones on two sides 122 Code 128 Length Control Variable 122 Code 128 Set Length 1 1 123 Code 128 Set Length 2 80...

Страница 291: ...le 135 Standard 2 of 5 Check Character Transmission Send 136 Standard 2 of 5 Length Control Variable 136 Standard 2 of 5 Set Length 1 8 137 Standard 2 of 5 Set Length 2 50 138 Industrial 2 of 5 Indust...

Страница 292: ...3 148 Codabar Set Length 2 50 149 ABC Codabar Disable 150 ABC Codabar ABC Codabar Enable Disable Disable 150 ABC Codabar Concatenation Mode Static 150 ABC Codabar Dynamic Concatenation Timeout 200 mse...

Страница 293: ...imited Enable Disable Disable 163 GS1 DataBar Limited GS1 128 Emula tion Disable 163 GS1 DataBar Limited 2D Component 2D component not required 164 Code 93 Code 93 Enable Disable Disable 164 Code 93 C...

Страница 294: ...l Control Normal 181 Aztec Code Enable Disable Disable 182 Aztec Code Length Control Enable 182 Aztec Code Length Control Variable 182 Aztec Code Set Length 1 1 183 China Sensible Code Enable Disable...

Страница 295: ...F417 Set Length 2 0366 199 QR Code Enable Disable Enable 200 QR Code Length Control Variable 200 QR Code Set Length 1 1 201 QR Code Set Length 2 7 089 202 Micro QR Code Enable Disable Disable 203 Micr...

Страница 296: ...utolink Unlink Label Required 220 Features for BT Models Only Source Radio Address Transmission Do not include 221 Source Radio Address Delimiter Char acter No Delimiter Character 222 Link Timeout 2 S...

Страница 297: ...e Guide 287 Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types 1D Bar Codes UPC A EAN 13 978033029095 Code 39 Code 128 Code 128 Int...

Страница 298: ...Sample Bar Codes 288 QuickScan I QD24XX QBT24XX QM24XX Sample Bar Codes continued Code 32 Codabar 13579 Code 93 Code 11 123456789...

Страница 299: ...ed 1234890hjio9900mnb GS1 DataBar Limited 08672345650916 GS1 DataBar variants must be enabled to read the bar codes below see GS1 DataBar Omnidirectional on page 157 GS1 DataBar 14 GS1 DataBar Omnidir...

Страница 300: ...Bar Codes 290 QuickScan I QD24XX QBT24XX QM24XX 2D Bar Codes Aztec Datamatrix China Sensible Code MaxiCode Test Message PDF 417 ABCabc Micro PDF 417 BV17453 QR Code 35900G9 Micro QR Code 123456 UCC Co...

Страница 301: ...Product Reference Guide 291 Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5 6 7 8 9...

Страница 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...

Страница 303: ...aracter Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII tab...

Страница 304: ...LE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C GS C RS C US C S _ 2x SP 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N...

Страница 305: ...02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9...

Страница 306: ...90 A 091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122...

Страница 307: ...112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 01...

Страница 308: ...Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x Sh Sh...

Страница 309: ...3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12...

Страница 310: ...C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6...

Страница 311: ...uct Reference Guide 301 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy components of Microsoft Windows in English and some oth...

Страница 312: ...Scancode Tables 302 QuickScan I QD24XX QBT24XX QM24XX NOTES...

Страница 313: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Страница 314: ...phone 1 541 683 5700 Fax 1 541 345 7140 2013 2014 Datalogic ADC Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U...

Отзывы: