QUICKSCAN
®
MOBILE
140
4.6.2
Overflow Control
The overflow control parameter can be disabled when decoding codes printed on
small surfaces, which do not allow the use of an overflow space.
This command does not affect code families 2/5, Code 128 and Code 93.
4.6.3
Interdigit Control
The interdigit control parameter verifies the interdigit spacing for code families Code
39 and Codabar.
4.7 RADIO PARAMETERS
4.7.1
Radio Protocol Timeout
This parameter sets the valid time to wait before transmission between the reader
and the cradle is considered failed.
This parameter should be set taking into consideration the radio traffic (number of
readers in the same area).
If the RS-232 interface is used with ACK/NACK enabled, this parameter should be at
least equal to the RX Timeout parameter for low traffic environments. It should be
increased if there are many readers in the same area.
It can be set between 2 and 19 seconds.
4.7.2
Power-Off Timeout
If this command is enabled, after the desired timeout in hours, the batteries are
disconnected and all power consumption ceases. To restore power, press the trigger
once. The reader will now be ready to read codes.
Power-off does not affect configuration parameters.
4.7.3
Beeper Control for Radio Response
The data entry good read tone normally results in two beeps; the first indicates that
the reader has decoded the code; the second indicates whether cradle has received
the data.
This can be changed according to the following selections:
♦
Normal: both good decode and good reception are signaled (two beeps).