DATA FORMAT

 

 

 

53

 

  AIM standard identifiers are not defined for all codes: the X identifier is assigned to the 

code for which the standard is not defined. The y value depends on the selected options 
(check digit tested or not, check digit tx or not, etc.). 

 
 

 

When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can 

be defined for each code type. If only 1 identifier character is required, the second 
character must be selected as FF (disabled). 

 
 

 

The code identifier can be singly disabled for any code by simply selecting FF as the first 

identifier character. 

 
 

 

Write in the Custom character identifiers in the table above for your records. 

 

Содержание QuickScan Mobile

Страница 1: ...2903 1 Fax 39 0 39 6859496 Japan Datalogic Scanning KK Shinagawa Tokyo Japan Telephone 81 0 3 3491 6761 Fax 81 0 3 3491 6656 Latin America Datalogic Scanning Inc Miami Florida USA Telephone 305 591 32...

Страница 2: ...on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions may eithe...

Страница 3: ...27 Handshaking 28 Ack Nack Protocol 28 Fifo 29 Inter character Delay 29 Rx Timeout 30 Serial Trigger Lock 30 Keyboard Nationality 31 Fifo 32 Inter character Delay 32 Inter code Delay 33 Control Charac...

Страница 4: ...eld Adjustment 59 Field Adjustment Character 60 Code Length Tx 60 Character Replacement 61 Address Stamping 63 Address Delimiter 63 READING PARAMETERS 64 Hand Held Operation 65 Stand Operation 65 Hard...

Страница 5: ...ode 16K 96 Code 49 96 GS1 DataBar 97 ADVANCED FORMATTING 98 Concatenation 99 Advanced Formatting 102 RADIO PARAMETERS 117 Radio Protocol Timeout 118 Power Off Timeout 118 Beeper Control for Radio Resp...

Страница 6: ...vi GENERAL VIEW QUICKSCAN MOBILE READERS Trigger Reading Window Cradle Locking System Latch Charge completed yellow LED Charging red LED...

Страница 7: ...nuous and multi tasking activities are keys to optimum productivity lower cost of ownership and profitable business 1 1 READING ANGLE QuickScan Mobile readers automatically scan barcodes at a distance...

Страница 8: ...QUICKSCAN MOBILE 2 1 2 HANDS FREE USE When using the QuickScan Mobile on the cradle remember to lock the reader by pushing up the locking system as indicated in the following figure...

Страница 9: ...charge before using the reader in hand held mode In hands free use you can immediately start using the reader since it is powered by the cradle 3 Configure the QuickScan Mobile reader 4 Configure the...

Страница 10: ...ce Figure 4 WARNING Do not incinerate disassemble short terminals or expose to high temperature Risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by an inc...

Страница 11: ...rface type 1 Connect the appropriate interface cable to the cradle by simply plugging it into the Host connector on the base of the cradle QuickScan Mobile Cradle Bottom View To disconnect the cable i...

Страница 12: ...QUICKSCAN MOBILE 6 2 4 RS 232 CONNECTION 2 5 USB 2 6 IBM USB POS 2 7 WEDGE CONNECTION only for Quickscan M2 Type 130 CAB 413 CAB 391 or CAB 321 CAB 431...

Страница 13: ...INSTALLATION 7 2 8 IBM PORT9B IBM PORT 5B only for Quickscan M2 Type 110 2 9 PEN EMULATION CONNECTION CAB 431 POWER SUPPLY ADAPTER CAB 431 POWER SUPPLY ADAPTER CAB 445 CAB 446...

Страница 14: ...QUICKSCAN MOBILE 8 2 10 SINGLE READER LAYOUT...

Страница 15: ...top of each page of configuration 3 Modify the desired parameters in one or more sections following the procedures given for each group 4 Read the Exit and Save Configuration code ONCE available at t...

Страница 16: ...e restore default parameters code below Restore QuickScan Mobile Default 1 o 2 Read the codes below to set the radio address of the QuickScan Mobile reader Enter configuration Set Radio Address 3 RA0R...

Страница 17: ...ithin 10 seconds a beep will be emitted signaling that the cradle has been paired to the QuickScan Mobile and the yellow LED on the reader will go off Read the cradle restore default code 7 Restore cr...

Страница 18: ...3 3 INTERFACE SELECTION Read the interface selection code for your application RS 232 Standard CP0 POS Terminals Nixdorf Mode A CM2EC0 Fujitsu CM1 ICL Mode CM0 For POS terminal default settings refer...

Страница 19: ...CONFIGURATION 13 WEDGE only for Quickscan M2 Type 130 IBM AT or PS 2 PCs CP500 a IBM XT CP503 v PC Notebook CP505 IBM SURE1 CP506 IBM Terminal 3153 CP504...

Страница 20: ...the interface for these IBM Terminals read the correct KEY TRANSMISSION code Select the KEYBOARD TYPE if necessary default advanced keyboard KEY TRANSMISSION MODE make only keyboard CP502 o make brea...

Страница 21: ...ently from the Keyboard Nationality used You do not need to make a Keyboard Nationality selection default Num Lock Unchanged Make sure the Num Lock key on your keyboard is ON IBM AT ALT mode CP507 PC...

Страница 22: ...WEDGE CONTINUED DIGITAL TERMINALS VT2xx VT3xx VT4xx CP512 u IBM 46XX only for Quickscan M2 Type 110 PORT 9B 4501 Protocol CP800 p typical 1520 Protocol CP801 w PORT 5B 1520 Protocol CP801 w typical 45...

Страница 23: ...start up phase ends correctly the yellow LED stops blinking In rare cases if the Host does not supply sufficient power to the reader a dialog box will appear on the Host and the reader will be blocke...

Страница 24: ...D APPLE UA05 F USB COM UA02 4 USB IBM Table Top UA00 USB IBM Hand Held UA01 When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software which ca...

Страница 25: ...EN EMULATION IBM 46xx only for Quickscan M2 type 110 The following parameter groups are common to all interface applications DATA FORMAT parameters regard the messages sent to the Host system for all...

Страница 26: ...R DELAY RX TIMEOUT SERIAL TRIGGER LOCK 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the proced...

Страница 27: ...Enter Configuration Exit and Save Configuration RS 232 21 BAUD RATE 300 baud CD1X 600 baud 1200 baud CD2 CD3 2400 baud 4800 baud CD4a CD5d 9600 baud 19200 baud CD6g CD7j 38400 baud CD8m...

Страница 28: ...Enter Configuration Exit and Save Configuration RS 232 22 PARITY none CC0S even parity CC1V odd parity CC2Y DATA BITS 7 bits CA0O 8 bits CA1R 9 bits CA2U...

Страница 29: ...onfiguration Exit and Save Configuration RS 232 23 STOP BITS 1 stop bit CB0Q 2 stop bits CB1T HANDSHAKING disable CE0W hardware RTS CTS CE1Z software XON XOFF CE2 RTS always ON CE3 See par 4 1 1 for d...

Страница 30: ...and Save Configuration RS 232 24 ACK NACK PROTOCOL disable ER0s enable ER1v See par 4 1 2 for details particularly on implementing this parameter with QuickScan Mobile FIFO disable EC0U enable EC1X S...

Страница 31: ...ed to Host CK3 Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseconds delay disabled RX TIMEOUT timeout control in reception from Host CL5 Read 2 numbers from the...

Страница 32: ...RIAL TRIGGER LOCK disabled CR0q enable and select characters CR1t Read 2 characters from the Hex Numeric table in the range 00 FE where First Character enables device trigger Second Character inhibits...

Страница 33: ...nter code delay Control character emulation USB keyboard speed USB IBM No parameter selection required 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration c...

Страница 34: ...Exit and Save Configuration USB COM 28 HANDSHAKING disable CE0W hardware RTS CTS CE1Z software XON XOFF CE2 RTS always ON CE3 See par 4 1 1 for details ACK NACK PROTOCOL disable ER0s enable ER1v See p...

Страница 35: ...n USB COM 29 FIFO disable EC0U enable EC1X See par 4 1 3 for details INTER CHARACTER DELAY delay between characters transmitted to Host CK3 Read 2 numbers from the table where 00 DELAY disabled 01 99...

Страница 36: ...UT disabled 01 99 TIMEOUT from 1 to 9 9 seconds rx timeout 5 seconds See par 4 1 4 for details SERIAL TRIGGER LOCK disabled CR0q enable and select characters CR1t Read 2 characters from the Hex Numeri...

Страница 37: ...ATIONALITY Not Available for USB KBD ALT MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default Belgian FJ7y English French FJ4p FJ2j Germ...

Страница 38: ...n USB KBD 32 FIFO disable EC0U enable EC1X See par 4 1 3 for details INTER CHARACTER DELAY delay between characters transmitted to Host CK3 Read 2 numbers from the table where 00 DELAY disabled 01 99...

Страница 39: ...ration USB KBD 33 INTER CODE DELAY delay between codes transmitted to Host FG Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 seconds delay disabled CONTROL CHARACTER EM...

Страница 40: ...Enter Configuration Exit and Save Configuration USB KBD 34 USB KEYBOARD SPEED Normal UT10c Fast UT01d...

Страница 41: ...DELAY KEYBOARD SETTING CONTROL CHARACTER EMULATION 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and foll...

Страница 42: ...nfiguration WEDGE 36 KEYBOARD NATIONALITY Belgian FJ7y English French FJ4p FJ2j German Italian FJ3m FJ1g Spanish Swedish FJ6v FJ5s USA FJ0d The Japanese Keyboard Nationality selection is valid only fo...

Страница 43: ...to match your keyboard caps lock status Note Caps lock manual configuration is ignored when Caps Lock Auto Recognition is enabled For PC Notebook interface selections the caps lock status is automatic...

Страница 44: ...is executed therefore it should be set as follows if your keyboard Num Lock is normally on use num lock unchanged if your keyboard Num Lock is normally off use toggle num lock In this way the device...

Страница 45: ...figuration Exit and Save Configuration WEDGE 39 INTER CODE DELAY delay between codes transmitted to Host FG Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 seconds delay...

Страница 46: ...essed and released key must generate an acoustic signal on the reader otherwise repress the key Never press more than one key at the same time even if this corresponds to the normal use of your keyboa...

Страница 47: ...4 3 47 J 70 25 4 48 K 71 26 5 49 L 72 27 6 50 M 73 74 DEL The keyboard setup functioning is signaled by the LEDs on the cradle Each key stroke corresponds to a double blinking of the yellow LED By pre...

Страница 48: ...Enter Configuration Exit and Save Configuration WEDGE 42 CONTROL CHARACTER EMULATION CTRL Shift Key FO0n CTRL Key FO1q...

Страница 49: ...OVERFLOW OUTPUT LEVEL IDLE LEVEL INTER BLOCK DELAY 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Default value 3 Read t...

Страница 50: ...e complete commands and do not require reading the Enter and Exit configuration codes OPERATING MODE interpret mode 8 Interprets commands without sending them to the decoder transparent mode 4 Sends c...

Страница 51: ...Exit and Save Configuration PEN EMULATION 45 MINIMUM OUTPUT PULSE 200 s DG0 400 s 600 s DG1_ DG2b 800 s 1 ms DG3e DG4h 1 2 ms low resolution code emulation high resolution code emulation DG5k See par...

Страница 52: ...TO CODE 39 AND CODE 128 disable conversion to Code 39 DA0P Transmits codes in their original format enable conversion to Code 39 DA1S Converts codes read into Code 39 format enable conversion to Code...

Страница 53: ...Exit and Save Configuration PEN EMULATION 47 OVERFLOW narrow DH0 medium DH1a wide DH2d See par 4 2 3 for details OUTPUT LEVEL normal white logic level 0 DD0V inverted white logic level 1 DD1Y See par...

Страница 54: ...normal black level DE0X inverted white level DE1 See par 4 2 4 for details INTER BLOCK DELAY delay between character blocks transmitted to Host CK3 Read 2 numbers from the table where 00 DELAY disable...

Страница 55: ...TING 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Default value 3 Read the Exit and Save Configuration code ONCE availa...

Страница 56: ...t and Save Configuration IBM 46xx 50 IBM DATA FORMATTING conversion to Code 39 GD0Y IBM Standard GD1 mixed IBM Standard Code 39 GD2_ Cradle check the Host command GE0 Cradle ignore Host command GE1 Se...

Страница 57: ...ER CODE LENGTH TX CHARACTER REPLACEMENT ADDRESS STAMPING ADDRESS DELIMITER 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups...

Страница 58: ...with 5 ADD ON E 2 M UPC A with 2 ADD ON X y F UPC A with 5 ADD ON X y G UPC E with 2 ADD ON X y H UPC E with 5 ADD ON X y I Code 39 A y V Code 39 Full ASCII A y W CODABAR F y R ABC CODABAR X y S Code...

Страница 59: ...igit tx or not etc When customizing the Datalogic Standard code identifiers 1 or 2 identifier characters can be defined for each code type If only 1 identifier character is required the second charact...

Страница 60: ...Enter Configuration Exit and Save Configuration DATA FORMAT 54 CODE IDENTIFIER disable EB0S Datalogic standard EB1V AIM standard EB2Y custom EB3...

Страница 61: ...You can define 1 or 2 identifier characters for each code type If only 1 identifier character is required the second character must be selected as FF disabled Read the hexadecimal value corresponding...

Страница 62: ...cter header six character header EA05 EA06B seven character header eight character header EA07F EA08J After selecting one of the desired Header codes read the character s from the HEX table Valid char...

Страница 63: ...aracter terminator six character terminator EA15A EA16E seven character terminator eight character terminator EA17I EA18M After selecting one of the desired Header codes read the character s from the...

Страница 64: ...Wedge IBM AT PS 2 and USB KBD Interfaces NOTE It is necessary to define each Special Key by following the procedure given in par 4 4 2 Select one or more of the following Special Keys according to yo...

Страница 65: ...tion right deletion 12 23 left deletion 34 f Read a number in the range 01 32 from the Hex Numeric Table to define how many characters to add or delete Conditions Adjustment is only performed on the b...

Страница 66: ...r Wedge and USB KBD interfaces it is also possible to read the Special Key s on page 58 Example To define the field adjustment character A Read field adjustment character 41 CODE LENGTH TX code length...

Страница 67: ...dix B read the Code Identifier for the desired code family 0 character replacement will be effective for all code families e From the Hex Numeric Table read two characters corresponding to the Hex val...

Страница 68: ...lacement Code 39 ASCII characters corresponding to the HEX value for character 0 ASCII characters corresponding to the HEX value for character 1 EO1p VW 30 31 For Code 39 codes containing the string 0...

Страница 69: ...G disable reader address stamping RU0 enable reader address stamping RU1 See par 4 4 3 for details ADDRESS DELIMITER disable reader address delimiter RV0 enable reader address delimiter and select cha...

Страница 70: ...PER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH STAND RECOGNITION BEEP 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups...

Страница 71: ...rigger BK1e software trigger always on BK0b BK3k not available for Mobile series readers automatic hardware trigger ready BK2h BK4n STAND OPERATION ONLY Devices with Stand Recognition Beep hardware tr...

Страница 72: ...r active pulse BA1Q See par 4 5 1 for details TRIGGER OFF TIMEOUT trigger off timeout BD Read 2 numbers in the range 00 99 00 disables the trigger off timeout 01 99 corresponds to a max 99 sec delay a...

Страница 73: ...ETERS 67 FLASH MODE FLASH ON duration BB0P FLASH OFF duration BB1S Read 2 numbers in the range 01 99 01 to 99 from 1 to 9 9 seconds Flash ON 1 sec Flash OFF 0 6 sec READS PER CYCLE one read per cycle...

Страница 74: ...at least 400 ms 01 99 timeout from 1 to 9 9 seconds before a consecutive read on same code safety time 0 5 sec See par 4 5 4 for details BEEPER INTENSITY very low intensity BG0Z low intensity medium i...

Страница 75: ...Enter Configuration Exit and Save Configuration READING PARAMETERS 69 BEEPER TONE tone 1 BH0 tone 2 tone 3 BH1_ BH2b tone 4 BH3e BEEPER TYPE monotone BJ0 bitonal BJ1c BEEPER LENGTH long BI0 short BI1a...

Страница 76: ...Enter Configuration Exit and Save Configuration READING PARAMETERS 70 STAND RECOGNITION BEEP ONLY Devices with Stand Recognition disable BV0x enable BV1...

Страница 77: ...AUTION Before changing these parameter values read the descriptions in par 4 6 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired gr...

Страница 78: ...Enter Configuration Exit and Save Configuration DECODING PARAMETERS 72 INK SPREAD disable AX0 enable AX1 See par 4 6 1 for details OVERFLOW CONTROL disable AW1 enable AW0y See par 4 6 2 for details...

Страница 79: ...DECODING PARAMETERS 73 INTERDIGIT CONTROL disable AV0w enable AV1z See par 4 6 3 for details DECODING SAFETY one read ED0W decoding safety disabled two reads three reads ED1Z ED2 four reads ED3 Requi...

Страница 80: ...read codes using this technology simply move the illuminated bar over the code so that each line of the code is scanned During this process a series of brief ticks indicates that reading is proceeding...

Страница 81: ...N DELTA IBM CODE 11 CODE 16K CODE 49 GS1 DATABAR 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow...

Страница 82: ...t limit the number of CODES enabled to 5 as it depends on the code family SINGLE SELECTIONS Example 5 code selections 1 2 5 Interleaved 2 2 5 Industrial 3 Code 128 EAN 128 4 Code 39 Full ASCII Code 32...

Страница 83: ...ILY disable the family AA0M c Read the desired family code Note Since the EAN UPC without ADD ON code selection is enabled by default to correctly enable another selection first disable the family WIT...

Страница 84: ...d Save Configuration CODE SELECTION 78 WITH ADD ON 2 AND 5 EAN 8 EAN 13 UPC A UPC E AA5 EAN 8 EAN 13 AA6_ UPC A UPC E AA7b WITH ADD ON 2 ONLY EAN 8 EAN 13 AAK7 UPC A UPC E AAM WITH ADD ON 5 ONLY EAN 8...

Страница 85: ...nd without ADD ON no Autodiscrimination AA8Ad03 EAN UPC Autodiscrimination ADD ON by Prefix AA8Ad19 By setting the EAN UPC Autodiscrimination ADD ON by Prefix the desired prefixes must be selected by...

Страница 86: ...ound the barcode will not be read Barcodes starting with different characters are read regardless of ADD ON presence and transmitted always without ADD ON Cancel All Selections ET0w OR select one or m...

Страница 87: ...and transmission with ADD ON of all EAN UPC barcodes starting with 434 439 prefixes 3 977 enables reading and transmission with ADD ON of all EAN UPC barcodes starting with 977 prefix 4 978 enables re...

Страница 88: ...AN UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choose to transmit the check digit or not CHECK DIGIT TRANSMISSION EAN 8 NO CHECK DIGIT TRANSMISSION AAG1o EAN 8 AAG0k EAN 13...

Страница 89: ...TIONS UPC E to UPC A conversion AAA UPC E to EAN 13 conversion AAB UPC A to EAN 13 conversion AAC EAN 8 to EAN 13 conversion AAD Enable only ISBN conversion AP1n Enable only ISSN conversion AP2q Enabl...

Страница 90: ...digit control without transmission Matrix 2 5 3 Bars 34 AC4 e Read 4 numbers for the code length where First 2 digits minimum code length Second 2 digits maximum code length The pharmaceutical code be...

Страница 91: ...39 FAMILY disables the family AB0O c Read the desired family code d Read a check digit selection Standard Code 39 CHECK DIGIT TABLE no check digit control AB1R 12 Full ASCII Code 39 check digit contro...

Страница 92: ...ical code CODE LENGTH optional The code length selection is valid for the entire Code 39 family Read the code 4 numbers for the code length where set code length First 2 digits minimum code length Sec...

Страница 93: ...t EAN 128 AI21 control without transmission of check digit Transmit GS Before Code Code EAN 128 uses the ASCII GS character to separate a variable length code field from the next code field This chara...

Страница 94: ...r the code length where First 2 digits minimum code length Second 2 digits maximum code length set code length AILJ The maximum code length is 99 characters The minimum code length must always be less...

Страница 95: ...mission selection START STOP CHARACTER TRANSMISSION Standard Codabar AD113 no start stop character equality control no transmission 12 Standard Codabar AD127 start stop character equality control tran...

Страница 96: ...ength where set code length First 2 digits minimum code length Second 2 digits maximum code length AD A The maximum code length is 99 characters The minimum code length must always be less than or equ...

Страница 97: ...rol AE1X MOD10 check digit control no check digit transmission AE2 MOD10 check digit control check digit transmission AE3 MOD11 MOD10 check digit control no check digit transmission AE4a MOD11 MOD10 c...

Страница 98: ...one of the check digit selections Standard Plessey no check digit control AF117 check digit control check digit transmitted AF12 check digit control check digit not transmitted AF13 Anker Plessey no c...

Страница 99: ...f the check digit selections Numeric Telepen no check digit control AL11C check digit control check digit transmitted AL12G check digit control check digit not transmitted AL13K Alphanumeric Telepen n...

Страница 100: ...nd Save Configuration CODE SELECTION 94 DELTA IBM disable the family AH0 Enable the code by selecting one of the check digit selections no check digit control AH1 Type 1 check digit control AH2a Type...

Страница 101: ...ol AG1 Type C check digit control check digit transmitted AG21 Type C check digit control check digit not transmitted AG22 Type K check digit control check digit transmitted AG31 Type K check digit co...

Страница 102: ...e so that each line of the code is scanned During this process a series of brief ticks indicates that reading is proceeding correctly CODE 49 disable the code AM0e Code 49 AM1h To read stacked codes s...

Страница 103: ...10I enable RSS Expanded Linear and Stacked disable RSS Limited AQ11M AQ20L enable RSS Limited disable RSS 14 Linear and Stacked AQ21P AQ30O enable RSS 14 Linear and Stacked AQ31S To read stacked codes...

Страница 104: ...Formatting parameters may not be compatible with the IBM USB POS interface selection 1 Read the Enter Configuration code ONCE available at the top of page 2 Read configuration codes precisely followin...

Страница 105: ...ype and length It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires The order of transmission is CODE 1 CODE 2 Define Concatenation 1 Code...

Страница 106: ...milies you must select the Code ID character of the resulting code The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection Datalogic A...

Страница 107: ...ORMATTING 101 5 Transmission after Timeout no code transmitted after timeout EM0i only code 1 transmitted if read after timeout EM1l only code 2 transmitted if read after timeout EM2o either code 1 or...

Страница 108: ...can be defined and saved in memory For each format you must complete the entire configuration procedure Define another Enable Advanced Formats 1 2 3 4 Define No Match Result Read the Exit and Save Co...

Страница 109: ...1W begin Format 3 definition HA2Z begin Format 4 definition HA3 2 Match Code Type match code type HB Read the above code the code type to match from the Code Identifier Table in Appendix B OR any code...

Страница 110: ...ned match code read the character s from the HEX table Range of characters 01 FE Example Match code with the 2 character predefined string Read Match with a 2 character string 40 40 AND position of fi...

Страница 111: ...this case you can choose to discard the code separator character or include it as the last character of the field OR BY b defining a match character to be found consecutively repeated in the code its...

Страница 112: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 1 Termina...

Страница 113: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 2 Termina...

Страница 114: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 3 Termina...

Страница 115: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 4 Termina...

Страница 116: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 5 Termina...

Страница 117: ...ed field HI3m 4 character fixed field HI4p 5 character fixed field HI5s 6 character fixed field HI6v After selecting one of the Additional Fixed Field codes read the corresponding character s from the...

Страница 118: ...fixed field HJ3o 4 character fixed field HJ4r 5 character fixed field HJ5u 6 character fixed field HJ6x After selecting one of the Additional Fixed Field codes read the corresponding character s from...

Страница 119: ...responding to the fields to transmit in the order in which they are to be transmitted A field can be transmitted more than once See example field 1 12 field 2 field 3 23 34 field 4 field 5 45 56 addit...

Страница 120: ...rd formatting HL1m After performing Advanced Formatting on the barcode read Standard Formatting Headers Code Length Code ID Terminators can be applied to the message to be transmitted 11 End Format De...

Страница 121: ...ED FORMATTING 115 Enable Advanced Format no Advanced Formats enabled HN0n Advanced Format 1 enable HN11N disable HN10J Advanced Format 2 enable HN21Q disable HN20M Advanced Format 3 enable HN31T disab...

Страница 122: ...using standard format HO1s This selection determines the action to be taken when codes read do not conform to the advanced format requisites no match Codes not matching can be ignored cleared from me...

Страница 123: ...RESPONSE SINGLE STORE BATCH MODE 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the procedure gi...

Страница 124: ...number from the table where 02 19 timeout from 2 to 19 seconds 2 seconds See par 4 7 1 for details POWER OFF TIMEOUT power off timeout RPL Read 2 numbers in the range 00 99 00 Power off disabled read...

Страница 125: ...Enter Configuration Exit and Save Configuration RADIO PARAMETERS 119 BEEPER CONTROL FOR RADIO RESPONSE normal BF0X only good decode only good reception BF1 BF2 off BF3a See par 4 7 3 for details...

Страница 126: ...ration RADIO PARAMETERS 120 SINGLE STORE disable RO0z one attempt two attempts RO1 RO2 three attempts four attempts RO3 RO4 five attempts six attempts RO5 RO6 seven attempts eight attempts RO7 RO8 nin...

Страница 127: ...ble batch enable normal batch BZ0 enable automatic batch BZ1 BZ2 See par 4 7 5 for details The following batch management parameters are complete commands and do not require reading the Enter and Exit...

Страница 128: ...he Host is active RTS Transmitted data Transmitted data TX CTS Host busy Signals at EIA levels RTS CTS handshaking Software handshaking XON XOFF During transmission if the Host sends the XOFF characte...

Страница 129: ...NACK protocol is enabled FIFO must be disabled manually see par 4 1 3 The transmission protocol takes place between reader cradle and Host The reader passes its data code read to the cradle which sen...

Страница 130: ...d on a First In First Out basis allowing faster data collection in certain cases for example when using slow baud rates and or hardware handshaking If the FIFO buffering is enabled codes are collected...

Страница 131: ...utput pulse corresponding to the narrowest element in the barcode In this way the code resolution is controlled by the signal sent to the decoder independently of the physical resolution of the code r...

Страница 132: ...times the minimum output pulse 4 2 4 Output and Idle Levels The following state diagrams describe the different output and idle level combinations for Pen emulation bar space white black barcode outp...

Страница 133: ...Data from any code selected may be transmitted Each code is transmitted to the Host as Code 39 Any character not included in the standard Code 39 set will be replaced with a Space 20 Hex IBM Standard...

Страница 134: ...put Message from QuickScan Mobile STAR System Towards Host Header Code ID Code Length CODE Terminator Items in square brackets are optional 4 4 1 Header Terminator Selection The header terminator sele...

Страница 135: ...10 F10 F10 8F F11 ESC F11 F11 90 F12 BACKSPACE F12 F12 91 HOME HOME ENTER F13 92 END END RESET F14 93 PG UP PG UP INSERT F15 94 PG DOWN PG DOWN DELETE F16 95 FIELD UP 96 FIELD DOWN 97 ENTER Paddle LEF...

Страница 136: ...cial Keys can be used for Headers Terminators Character Replacement Field Adjustment Custom Code ID Advanced Formatting Define Field Advanced Formatting Additional Fixed Field Follow the procedure to...

Страница 137: ...Exit and Save Configuration 131 2 Read only one code to be associated with the special key sequence SHIFT 12 OR CTRL 23 OR ALT 45 OR CTRL SHIFT 34 OR ALT SHIFT 56 OR CTRL ALT 67...

Страница 138: ...25 S 025 S 025 S 025 A 025 S 02E S 02E S 052 S 052 S 02E S 02E S 02E S 02E S 02E S 036 S 03D S 016 016 036 S 03D S 036 S 036 S 036 S 04E 052 025 025 05D S 052 04E 05D 03D S 03E S 046 S 02E 02E 03E S 0...

Страница 139: ...4 055 S 054 S a 01C 01C 015 015 01C 01C 01C 01C 01C b 032 032 032 032 032 032 032 032 032 c 021 021 021 021 021 021 021 021 021 d 023 023 023 023 023 023 023 023 023 e 024 024 024 024 024 024 024 024...

Страница 140: ...board nationalities ITA USA FR BE DE UK ES SW JP ENTER 05A 05A 05A 05A 05A 05A 05A 05A 05A TAB 00D 00D 00D 00D 00D 00D 00D 00D 00D F1 005 005 005 005 005 005 005 005 005 F2 006 006 006 006 006 006 006...

Страница 141: ...14 214 214 214 214 02E A 02E A 024 A 024 A 024 A 025 A 02E A 02E A SPACE 029 029 029 029 029 029 NOTE If Caps Lock Auto Recognition is disabled it is necessary to verify that the keyboard caps lock st...

Страница 142: ...ead FQ9E2F 45 codes from Appendix C corresponding to the character value for F6 exit save configuration 00B 4 the following example allows defining Special Key 4 as Alt Shift F1 enter configuration de...

Страница 143: ...rminators enter configuration two character terminator special key 4 ASCII characters corresponding to the HEX value for character ENTER Read EA125 9F 83 exit save configuration 4 4 3 Address Stamping...

Страница 144: ...s controlled when the hardware trigger operating mode is selected trigger active level the reader goes ON when the trigger is pressed and goes OFF when it is released trigger active pulse the reader g...

Страница 145: ...xpires The Safety Time parameter should be used in this case to avoid unwanted multiple reading of the same code see par 4 5 4 4 5 4 Safety Time Safety time prevents the device from immediately decodi...

Страница 146: ...32 interface is used with ACK NACK enabled this parameter should be at least equal to the RX Timeout parameter for low traffic environments It should be increased if there are many readers in the same...

Страница 147: ...g the code since it is already stored in the reader Conversely if single store is disabled and the user wants to retry transmission the code must be read again and therefore the attempt must be made f...

Страница 148: ...red in the reader on a FIFO basis whenever the reader is out of radio range In this case radio communication is not suspended and transmission is attempted after each code read If transmission cannot...

Страница 149: ...default settings K Transmit the reader Software release _ Transmit the reader configuration in ASCII format This command is not effective with Pen emulation interface or with the reader model RX0 q R...

Страница 150: ...fier Custom Custom Custom Header No Header No Header No Header Terminator CR CR CR Field Adjustment Disabled Disabled Disabled Code Length TX Not Transmitted Not Transmitted Not Transmitted Character...

Страница 151: ...ical Features Sensor CCD solid state 2088 pixels Illuminator LED array Wavelength 630 670 nm Max LED Output Power 0 33 mW LED safety class Class 1 EN 60825 1 Reading field see reading diagram Max reso...

Страница 152: ...mopan 3855 Mechanical Features CRADLE Weight 181 gr 6 38 oz Dimensions 80 x 130 x 90 mm 3 15 x 5 11 x 3 54 in Material Cycoloy C 2800 with desmopan 3855 QuickScan Mobile Radio Features Radio Features...

Страница 153: ...rk 16 5 2 STATUS INDICATORS The reader has a LED indicator and a Beeper The cradle has three LEDs They signal several operating conditions which are described in the tables below H high tone L low ton...

Страница 154: ...code READER POWER Beeper LED Meaning 10 short H 10 short blinks Low Battery READER BIND AND JOIN Beeper LED Meaning Blinking Command accepted reader ready to be inserted into the cradle L Success H L...

Страница 155: ...ging out of temperature range over current or over voltage conditions ON Power applied Blinking Receiving data and commands from the Host or the reader 5 3 READING DIAGRAMS QUICKSCAN MOBILE Reading di...

Страница 156: ...er configuration environment Exit and Save configuration Example Beeper tone 1 Beeper low intensity BG1 CR Carriage return character 0D Hex Exit and save new configuration AC410132 BH0 Matrix 2 5 3 ba...

Страница 157: ...x make break keyboard CP501 for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard CP502 typewriter FK0 Keyboard Type for IBM Terminals 31xx 32xx 34xx 37xx advanced FK1 for IBM XT CP503 for IBM Term...

Страница 158: ...able CE0 RTS CTS CE1 XON XOFF CE2 RTS always On CE3 ACK NACK Protocol disable ER0 enable ER1 FIFO disable EC0 enable EC1 Inter character delay ms CK00 CK99 RX Timeout 100 ms CL00 CL99 disable CR0 Seri...

Страница 159: ...Keyboard nationality Belgian FJ7 not for USB KBD ALT MODE English FJ4 French FJ2 German FJ3 Italian FJ1 Japanese FJ8 Spanish FJ6 Swedish FJ5 USA FJ0 FIFO disable EC0 enable EC1 Delays Inter Character...

Страница 160: ...er ms CK00 CK99 Delays Inter Code s FG00 FG99 Control Character Emulation CTRL Shift Key FO0 CTRL Key FO1 PEN DESCRIPTION STRING Operating mode interpret does not require or transparent does not requi...

Страница 161: ...characters EA12xx three characters EA13xxx four characters EA14xxxx five characters EA15xxxxx six characters EA16xxxxxx seven characters EA17xxxxxxx eight characters EA18xxxxxxxx Special Keys special...

Страница 162: ...Address Stamping disable reader address stamping RU0 enable reader address stamping RU1 disable reader address delimiter RV0 Address Delimiter enable reader address delimiter and select character RV1...

Страница 163: ...ode trigger active level BA0 trigger active pulse BA1 Trigger off Timeout s BD00 BD99 FLASH ON 100 ms BB001 BB099 FLASH OFF 100 ms BB101 BB199 Reads per Cycle one read BC0 multiple reads BC1 Safety Ti...

Страница 164: ...h ADD ON AA5 EAN 8 EAN 13 without ADD ON AA3 with ADD ON 2 ONLY AAK with ADD ON 5 ONLY AAL with ADD ON 2 AND 5 AA6 UPC A UPC E without ADD ON AA4 with ADD ON 2 ONLY AAM with ADD ON 5 ONLY AAN with ADD...

Страница 165: ...ontrol AC11xxxx check digit control and transmission AC12xxxx check digit control without transmission AC13xxxx Normal 2 5 5 bars no check digit control AC21xxxx check digit control and transmission A...

Страница 166: ...without transmission of check digit AI11 enable EAN 128 control without transmission of check digit AI21 disable EQ0 Transmit GS before Code enable EQ1 ISBT 128 enable ISBT 128 AI31 code length AILxxx...

Страница 167: ...tx AL22 Alpha check no tx AL23 Delta IBM disable the family AH0 no check AH1 Type 1 check AH2 Type 2 check AH3 Code 11 disable the family AG0 no check AG1 Type C with tx AG21 Type C no tx AG22 Type K...

Страница 168: ...normal BF0 only good decode BF1 only good reception BF2 Beeper Control For Radio Response off BF3 disable RO0 one attempt RO1 two attempts RO2 three attempts RO3 four attempts RO4 five attempts RO5 s...

Страница 169: ...ER TABLE 2 5 Interleaved NO 2 5 Industrial 2 5 normal 5 bars PQ OP 2 5 matrix 3 bars EAN 8 QR AB EAN 13 UPC A BC CD UPC E EAN 8 with 2 ADD ON DE JK EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON KL LM EAN 1...

Страница 170: ...ILE 164 UPC A with 5 ADD ON GH UPC E with 2 ADD ON UPC E with 5 ADD ON HI IJ Code 39 Code 39 Full ASCII VW WX CODABAR ABC CODABAR RS ST Code 128 EAN 128 TU kl Code 93 CIP 39 UV YZ CIP HR Code 32 ef XY...

Страница 171: ...E IDENTIFIER TABLE 165 MSI Z Plessey Anker Plessey Standard op ab Delta IBM Telepen cd de Code 16K Code 11 pq bc Code 49 RSS Expanded Linear and Stacked qr tu RSS Limited RSS 14 Linear and Stacked vw...

Страница 172: ...VT 0B 5 35 60 FF 0C 6 36 a 61 CR 0D 7 37 b 62 SO 0E 8 38 c 63 SI 0F 9 39 d 64 DLE 10 3A e 65 DC1 11 3B f 66 DC2 12 3C g 67 DC3 13 3D h 68 DC4 14 3E i 69 NAK 15 3F j 6A SYN 16 40 k 6B ETB 17 A 41 l 6C...

Страница 173: ...F10 8E B8 E3 F11 8F B9 E4 F12 90 BA E5 HOME 91 BB E6 END 92 BC E7 Pg UP 93 BD E8 Pg Down 94 BE E9 95 BF EA 96 C0 EB 97 C1 EC 98 C2 ED ESC 99 C3 EE CTRL Right 9A C4 EF 9B C5 F0 9C C6 F1 9D C7 F2 9E C8...

Страница 174: ...F10 8E B8 E3 F11 8F B9 E4 F12 90 BA E5 HOME 91 BB E6 END 92 BC E7 Pg UP 93 BD E8 Pg Down 94 BE E9 95 BF EA 96 C0 EB 97 C1 EC 98 C2 ED ESC 99 C3 EE CTRL Right 9A C4 EF 9B C5 F0 9C C6 F1 9D C7 F2 9E C8...

Страница 175: ...d upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf da das Produkt den folgenden Nor...

Страница 176: ...1 italy scanning datalogic com Japan Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning dat...

Отзывы: