Enter/Exit Programming Mode
Product Reference Guide
77
Green Spot Duration
Specifies the duration of the good read pointer beam after a good read.
$CLSSP00(CR)
Green Spot Duration = Disable (Green Spot is Off )
$CLSSP01(CR)
Green Spot Duration = Short (300 msec)
DEFAULT
$CLSSP02(CR)
Green Spot Duration = Medium (500 msec)
$CLSSP03(CR)
Green Spot Duration = Long (800 msec)
Mobile Phone Mode
This mode is useful for scanning bar codes displayed on a mobile phone. Other options for this feature can be
configured using the Datalogic Aladdin application.
$CSNPE00(CR)
Mobile Phone Mode = Disable
$CSNPE01(CR)
Mobile Phone Mode = Enable
DEFAULT