background image

Enter/Exit Programming Mode

Product Reference Guide

        

                  

 265

RF Batch Mode Transmit Delay

Specifies the delay in 10 msec increments between transmitting labels stored in 

batch memory.

RF Batch Mode Transmit Delay = No Delay

RF Batch Mode Transmit Delay = 50 mS

RF Batch Mode Transmit Delay = 100 mS

RF Batch Mode Transmit Delay = 0.5 seconds

RF Batch Mode Transmit Delay = 1 second

RF Batch Mode Transmit Delay = 2.5 seconds

DEFAULT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание QBT2101-BK-BTK+

Страница 1: ...QuickScanTM I QD21X1 QM21X1 QBT21X1 General Purpose Handheld Linear Imager Barcode Reader Product Reference Guide...

Страница 2: ...of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Elec tronic versions may either be downloadable f...

Страница 3: ...e Battery Pack 14 Battery Safety 15 Replacing the Battery Pack 17 Programming 18 Select the Interface Type 18 Configure Interface Settings 18 Configure Other Features 18 Software Version Transmission...

Страница 4: ...ividually Per Symbology 63 Label ID Control 63 Label ID Symbology Selection 64 Set Global Mid Label ID Character s 70 Case Conversion 71 Character Conversion 72 Reading Parameters 73 Double Read Timeo...

Страница 5: ...EAN Two Label Enable Disable 107 EAN Two Label Combined Transmission 107 EAN Two Label Minimum Reads 108 UPC EAN Global Settings 109 UPC EAN Decoding Level 109 UPC EAN Correlation 110 UPC EAN Price We...

Страница 6: ...to Code 39 149 Code 128 Check Character Transmission 149 Code 128 Function Character Transmission 150 Code 128 Sub Code Change Transmission 150 Code 128 Quiet Zones 151 Code 128 Minimum Reads 152 Cod...

Страница 7: ...1 191 Code 11 Enable Disable 191 Code 11 Check Character Calculation 192 Code 11 Check Character Transmission 192 Code 11 Minimum Reads 193 Code 11 Length Control 194 Code 11 Set Length 1 195 Code 11...

Страница 8: ...7 Code 93 Decoding Level 228 Code 93 Quiet Zones 229 Code 93 Stitching 230 Code 93 Character Correlation 230 Codablock F 231 Codablock F Enable Disable 231 Codablock F EAN Enable Disable 231 Codablock...

Страница 9: ...haracter Delay 288 Intercode Delay 289 Data Editing 290 Data Editing Overview 290 Global Prefix Suffix 291 Global AIM ID 292 Label ID Pre loaded Sets 293 Label ID Set Individually Per Symbology 295 Se...

Страница 10: ...E TABLES 339 Control Character Emulation 339 Single Press and Release Keys 339 Interface Type PC AT PS 2 or USB Keyboard 340 Interface type PC AT PS 2 Alt Mode or USB Keyboard Alt Mode 342 Digital Int...

Страница 11: ...mming bar codes within this guide Programming can alternatively be performed using the Datalogic Aladdin Configuration application which is downloadable from the Datalogic website listed on the back c...

Страница 12: ...RG the Datalogic Aladdin Configuration application software firmware and any additional manuals instruction sheets and utilities for this product can be downloaded from the website listed on the back...

Страница 13: ...board Wedge KBW When connected using this interface the host interprets scanned data as keystrokes and supports several international keyboards for the Windows environment See Country Mode on page 46...

Страница 14: ...are and any additional manuals instruction sheets and utilities for this product can be downloaded from the website listed on the back cover of this manual Alternatively printed copies or product supp...

Страница 15: ...rdered Keyboard Wedge Connection The Keyboard Wedge cable has a Y connection from the reader Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the term...

Страница 16: ...f the Base Station 2 Securely plug the Power Cable if used and Interface I F Cable connectors into their respective ports in the underside of the Base Station 3 After the cables are plugged in reinser...

Страница 17: ...ment to a system that uses a custom security PIN See Connect ing the Base when Security Pin is Enabled starting on page 10 for more information Most connections plug directly into the host device as s...

Страница 18: ...ocking mechanism to ensure electrical contact between Reader and Base in case of inadvertent movements Lock Lever To Lock the Reader in the Base 1 Insert the Reader into the Base The lock lever rests...

Страница 19: ...ion System and Network Layout Typical Setup with Cradle and Host Figure 7 Reader Layout Reader Base Station Host Power Supply NOTE It is good practice to put the reader in the locked condition at the...

Страница 20: ...To link the handheld and the base press the trigger to wake it and place it on the base If the reader was previously linked to another base you must first scan the Unlink action command before re link...

Страница 21: ...on the PC to link the reader to the PC Use an RS 232 ter minal program to see incoming data on the port designated by the com puter s Bluetooth manager Linking to a PC in Client Mode BT Master Mode Th...

Страница 22: ...any drivers provided with the Bluetooth adapter 2 Scan the Link to PC in HID label below 3 Use the host computer s Bluetooth manager to Discover new devices and select Datalogic Scanner If you receiv...

Страница 23: ...ure 8 QuickScan Base LEDs YELLOW LED RED LED GREEN LED Table 1 Radio Base LEDs LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and commands from the Host or the R...

Страница 24: ...tion The LEDs on the base shown in Table 1 on page 13 will indicate the status of the battery NOTE Before using the battery read Battery Safety in the following section Datalogic rec ommends annual re...

Страница 25: ...ubject it to strong impacts or shocks Do not solder directly onto the battery pack Do not expose the battery pack to liquids or allow the battery to get wet Do not apply voltages to the battery pack c...

Страница 26: ...time at fully charged status or at fully discharged status should be avoided The useful life of LI batteries depends on usage and number of charges etc after which they should be removed from service...

Страница 27: ...ay from the reader To mount the new battery pack reverse the process 1 Insert the top of the new pack inside the reader s handle 2 Rotate the battery pack downward while pressing the bottom side of th...

Страница 28: ...atures stan dard to the interface type you ordered If after scanning the interface bar code from the Interfaces section your installation requires you to select options to further customize your reade...

Страница 29: ...f you aren t sure what programming options are in your reader or you ve changed some options and want to restore the Factory Configuration you have two options You can scan the Restore USA Factory Con...

Страница 30: ...20 QuickScan I QD21X1 QM21X1 QBT21X1...

Страница 31: ...o Next pro ceed to the corresponding chapter in this manual also listed in Table 2 to con figure any desired settings and features associated with that interface NOTE Unlike some other programming fea...

Страница 32: ...232 WN RS 232 Wincor Nixdorf RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS Select USB COM STDa USB Com to simulate RS 232 standard interface r p_J l bj cb qr obp USB OEM can be used for OP...

Страница 33: ...11 P Select KBD AT NK Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key P HA26 P Select KBD AT ALT P HA...

Страница 34: ...SB Alternate Keyboard USB Keyboard with alternate key encoding Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Select KBD IBM MB Keyboard Wedge for IBM Termina...

Страница 35: ...es exit Programming Mode and return the reader to normal operation NOTE There are some exceptions to the typical programming sequence described above Please read the description and setting instructio...

Страница 36: ...codes code families and their options To program features 1 Scan the ENTER EXIT PROGRAMMING bar code available at the top of each programming page when applicable 2 Scan the bar code to set the desire...

Страница 37: ...ion of this manual RS 232 ONLY Interface on page 29 RS 232 USB COM and Keyboard BT HID Interfaces on page 34 Keyboard Interface on page 45 USB OEM Interface on page 57 Host Commands Obey Ignore This o...

Страница 38: ...bal Interface Features 28 QuickScan I QD21X1 QM21X1 QBT21X1 USB Suspend Mode This setting enables disables the ability of USB interfaces to enter suspend mode USB Suspend Mode Disable USB Suspend Mode...

Страница 39: ...r system s requirements Additional settings which apply to both the RS 232 and USB interfaces are available in Chapter 6 RS 232 and USB COM Interfaces BAUD RATE on page 30 PARITY on page 33 DATA BITS...

Страница 40: ...transmitted per second Set the reader s baud rate to match the baud rate setting of the host device With an improper baud rate setting data may not reach the host correctly Baud Rate 1200 Baud Rate 2...

Страница 41: ...uide 31 Baud Rate continued Data Bits This parameter allows the reader to interface with devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data 7 Data Bits 8 Data Bits CR2BA0...

Страница 42: ...end of trans mission of one character and prepares the receiving device for the next charac ter in the serial data stream The number of stop bits selected one or two depends on the number the receivi...

Страница 43: ...e according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are...

Страница 44: ...S RTS is asserted during transmissions CTS gates transmis sions RTS XON XOFF RTS is asserted during transmissions CTS is ignored XON and XOFF gate transmissions RTS On CTS RTS is always asserted CTS g...

Страница 45: ...OM interfaces INTERCHARACTER DELAY on page 36 BEEP ON ASCII BEL on page 37 BEEP ON NOT ON FILE on page 37 ACK CHARACTER on page 39 NAK CHARACTER on page 39 ACK NAK TIMEOUT VALUE on page 40 ACK NAK RET...

Страница 46: ...range of zero 0 to 990 milliseconds in 10ms increments A setting of zero specifies no delay See Intercharacter Delay on page 280 or Intercharacter Delay on page 288 for more detailed programming instr...

Страница 47: ...2 serial line BEL is issued to gain a user s attention to an illegal entry or other important event Beep On ASCII BEL Disable Beep On ASCII BEL Enable Beep On Not on File This option enables disables...

Страница 48: ...sable Enable for label transmission The reader expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge The reader will respond with ACK NAK when the host sen...

Страница 49: ...ese char acters 8 bit data is not recognized when the option Data Bits on page 31 has been set as 7 Data Bits NAK Character This setting specifies an ASCII character or hex value to be used as the NAK...

Страница 50: ...The selectable timeout range is 200 milliseconds to 15 000ms 15 seconds in 200ms increments A selection of 0 disables the timeout See ACK NAK Timeout Value on page 283 for more detailed programming i...

Страница 51: ...tion The selectable range is from 1 to 254 retries A selection of 0 disables the count and a selection of 255 specifies unlimited retries See ACK NAK Retry Count on page 284 for more detailed program...

Страница 52: ...errors detected while waiting for an ACK character from the host Options are Ignore errors detected Process error as valid ACK character Process error as valid NAK character ACK NAK Error Handling Ign...

Страница 53: ...Character Specifies the value of the RS 232 host command used to disable the reader ASCII characters or any hex value from 0 to 0xFF can be selected See Disable Character on page 285 for more detailed...

Страница 54: ...from 0 to 0xFF can be selected See Enable Character on page 286 for more detailed programming instructions NOTE Select Enable Character Setting Setting to previously defined characters such as XON XOF...

Страница 55: ...KEYBOARD NUMERIC KEYPAD on page 50 KEYBOARD SEND CONTROL CHARACTERS on page 51 WEDGE QUIET INTERVAL on page 52 INTERCODE DELAY on page 53 USB KEYBOARD SPEED on page 54 Standard Factory Settings Refer...

Страница 56: ...key encoding Keyboard Wedge BT HID Below are the Country Modes supported by each product version Standard or European Supported Country Codes Standard Version European Version English USA Spanish Lati...

Страница 57: ...Guide 47 Country Mode continued CKBCO02 Country Mode English British CKBCO11 Country Mode Croatian CKBCO0E Country Mode Czech CKBCO03 Country Mode Danish CKBCO04 Country Mode French CKBCO05 Country Mo...

Страница 58: ...21X1 QBT21X1 Country Mode continued CKBCO06 Country Mode Italian CKBCO0C Country Mode Japanese 106 key CKBCO07 Country Mode Norwegian CKBCO12 Country Mode Polish CKBCO08 Country Mode Portuguese Brazil...

Страница 59: ...sends character data This applies to Keyboard Wedge interfaces This does not apply when an alternate key encoding keyboard is selected Caps Lock State Caps Lock OFF Caps Lock State Caps Lock ON Caps...

Страница 60: ...applies to alternate key encoding inter faces It does not apply to USB Keyboard Numlock Numlock key unchanged Numlock Numlock key toggled Keyboard Numeric Keypad This feature specifies if numeric char...

Страница 61: ...tted in the format Ctrl Key Special keys are available in the range from 81H to A1 Send Ctrl Shift Key The behavior is the same as above but control keys are sent in the format Ctrl Shift Keys Send Sp...

Страница 62: ...smit data to host The selectable range for this feature is from 0 to 990ms in 10ms increments See Wedge Quiet Interval on page 287 for more detailed programming instruc tions NOTE Select Wedge Quiet I...

Страница 63: ...t for this interface The selectable range for this feature is from 0 to 99 seconds See Intercode Delay on page 289 for more detailed programming instructions Set Intercode Delay Make a mistake Scan th...

Страница 64: ...ard Speed This option specifies the USB poll rate for a USB Keyboard NOTE USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keyboard Speed 3ms USB Keyboard Speed 4ms USB Keyboard Speed 5ms This featur...

Страница 65: ...Programming Mode Product Reference Guide 55 USB Keyboard Speed continued CKBSP06 USB Keyboard Speed 6ms CKBSP07 USB Keyboard Speed 7ms CKBSP08 USB Keyboard Speed 8ms CKBSP09 USB Keyboard Speed 9ms CK...

Страница 66: ...Enter Exit Programming Mode USB Keyboard Speed 56 QuickScan I QD21X1 QM21X1 QBT21X1 NOTES...

Страница 67: ...ces differ depending upon which host type the reader will be connected with Use the feature settings in this chapter to specif ically configure for the USB OEM interface Other USB interfaces are inclu...

Страница 68: ...mmunicate Options are Table Top Scanner Handheld Scanner NOTE USB OEM Device Usage Table Top Scanner USB OEM Device Usage Handheld Scanner It may be necessary to switch device usage when connecting tw...

Страница 69: ...on page 63 Label ID Symbology Selection on page 64 SET GLOBAL MID LABEL ID CHARACTER S on page 70 CASE CONVERSION on page 71 CHARACTER CONVERSION on page 72 Product Reference Guide 59 Data Format The...

Страница 70: ...sition before the bar code data and or as a suffix in a position following the bar code data as indi cated in Global Prefix Suffix on page 291 Set Global Prefix Set Global Suffix Make a mistake Scan t...

Страница 71: ...structions Global AIM ID Disable Global AIM ID Enable GS1 128 AIM ID If Global AIM ID is disabled the AIM ID for GS1 128 can be enabled disabled independently The AIM ID for GS1 128 is a C1 C2 or C3 A...

Страница 72: ...er Sym bology on page 63 If you wish to program the reader to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 61 Label ID Pr...

Страница 73: ...dividually Per Symbology on page 295 for more detailed programming instructions Label ID Control This option controls whether a Label ID is disabled or sent as a prefix or suffix for a given symbology...

Страница 74: ...configured See Label ID Set Individually Per Symbology on page 295 Set UPC A Label ID Character s Set UPC A P2 Label ID Character s Set UPC A P5 Label ID Character s Set UPC A GS1 128 Label ID Charact...

Страница 75: ...PC E GS1 128 Label ID Character s C3BID Set EAN 13 Label ID Character s C32ID Set EAN 13 P2 Label ID Character s C35ID Set EAN 13 P5 Label ID Character s C38ID Set EAN 13 GS1 128 Label ID Character s...

Страница 76: ...el ID Character s C4BID Set GS1 DataBar Omnidirectional Label ID Character s CXBID Set GS1 DataBar Expanded Label ID Character s CLBID Set GS1 DataBar Limited Label ID Character s CC3ID Set Code 39 La...

Страница 77: ...acter s CCBID Set Codabar Label ID Character s CI2ID Set Interleaved 2 of 5 Label ID Character s CHRID Set Interleaved 2 of 5 CIP HR Label ID Character s CD2ID Set Datalogic 2 of 5 CIP HR Label ID Cha...

Страница 78: ...t Industrial 2 of 5 Label ID Character s CINID Set ISSN Label ID Character s CIAID Set IATA Label ID Character s CI8ID Set Concatenated ISBT 128 Label ID Character s CMSID Set MSI Label ID Character s...

Страница 79: ...ology Selection continued CCC5ID Set Code 5 Label ID Character s CF2ID Set Follett 2 of 5 Label ID Character s CISID Set ISBN Label ID Character s CI8ID Set Concatenated ISBT Label ID Character s CALI...

Страница 80: ...hen com bining two label pairs into a single label for transmission to the host this label ID can be added to the data following the first label and preceding the second label See Set Global Mid Label...

Страница 81: ...Conversion Convert to lower case Case conversion affects ONLY scanned bar code data and does not affect Label ID Prefix Suffix or other appended data This feature allows conversion of the case of all...

Страница 82: ...ented in hexadecimal ASCII values The first character in the pair is the character that will be converted The second character in the pair is the character to convert to If the character to convert in...

Страница 83: ...ERT on page 77 STAND DETECTION on page 85 GOOD READ WHEN TO INDICATE on page 78 STAND MODE SENSITIVITY on page 86 GOOD READ BEEP TYPE on page 79 SCANNING ACTIVE TIME on page 86 GOOD READ BEEP FREQUENC...

Страница 84: ...gy and data If the unit reads a label and sees the same label again within the Double Read Timeout the second read of the label will be ignored Double Read Time out does not apply to scan modes that r...

Страница 85: ...imeout 0 7 Second Double Read Timeout 0 8 Second Double Read Timeout 0 9 Second Double Read Timeout 1 Second Reading Parameters Enter Exit Programming Mode Product Reference Guide 75 Double Read Timeo...

Страница 86: ...10 millisec onds to 2 550 milliseconds 2 55 seconds in 10ms increments Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read See Label Gone Timeout on...

Страница 87: ...oduct Reference Guide 77 LED and Beeper Indicators Power On Alert Disables or enables the indication from the Beeper that the reader is receiving power CBPPU00 Power On Alert Disable No Audible Indica...

Страница 88: ...D upon successfully reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then activ NOTE This option which uses C...

Страница 89: ...Frequency Adjusts the good read beep to sound at a selectable low medium or high fre quency selectable from the list below Controls the beeper s pitch tone CBPTY00 Good Read Beep Type Mono CBPTY01 Goo...

Страница 90: ...th Specifies the duration of a good read beep CBPLE06 Good Read Beep Length 60 msec CBPLE08 Good Read Beep Length 80 msec CBPLE0A Good Read Beep Length 100 msec CBPLE0C Good Read Beep Length 120 msec...

Страница 91: ...s upon a good read beep There are three selectable volume levels Good Read Beep Volume Beeper Off Good Read Beep Volume Low Good Read Beep Volume Medium Good Read Beep Volume High Good Read Beep Lengt...

Страница 92: ...a range of 0 1 to 25 5 seconds in 100ms increments A setting of 00 keeps the LED on until the next trigger pull See Good Read LED Duration on page 300 for more detailed programming instructions Select...

Страница 93: ...or more detailed programming instructions Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Autosense Stand Mod...

Страница 94: ...ger is pulled while in Autosense Stand Mode on page 301 NOTE Stand Mode Triggered Timeout 0 5 Seconds Stand Mode Triggered Timeout 1 5 Seconds Stand Mode Triggered Timeout 2 Seconds Stand Mode Trigger...

Страница 95: ...ior of the scanner when placed in a stand that contains autorecognition hardware Ignore Autorecognition Switch to Stand Mode Switch to Always On Switch to Flashing CSNOT0C Stand Mode Triggered Timeout...

Страница 96: ...ime This setting specifies the amount of time that the reader stays in scan ON state once the state is entered The range for this setting is from 1 to 255 seconds in 1 second increments See Scanning A...

Страница 97: ...The selectable range is 100 to 9 900 milliseconds 0 1 to 9 9 seconds in 100 millisecond increments See Flash On Time on page 303 for more detailed programming instructions Select Flash ON Time Settin...

Страница 98: ...e detailed programming instructions Select Flash OFF Time Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL Green...

Страница 99: ...taBarTM Limited on page 131 MSI on page 217 Code 39 on page 133 Code 93 on page 223 Code 32 Italian Pharmaceutical on page 146 Codablock F on page 231 Code 39 CIP French Pharmaceutical on page 148 Cod...

Страница 100: ...enables only UPC EAN coupon decoding Enable only GS1 DataBar enables only GS1 DataBar coupon decoding To set this feature 1 Scan the Enter Exit bar code 2 Scan either the enable or disable bar code b...

Страница 101: ...sable When disabled the reader will not read UPC A bar codes UPC A Disable UPC A Enable UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A bar code...

Страница 102: ...hanges the symbology ID to match those required for EAN 13 UPC A to EAN 13 Don t Expand UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables disables transmission of...

Страница 103: ...ed before it is accepted as good read In store labels are defined as UPC A labels with a number system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 l...

Страница 104: ...Disable When disabled the reader will not read UPC E bar codes UPC E Disable UPC E Enable UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E bar cod...

Страница 105: ...13 data format Selecting this feature also changes the symbology ID to match those required for EAN 13 UPC E to EAN 13 Don t Expand UPC E to EAN 13 Expand Expand UPC E to UPC A Expands UPC E data to...

Страница 106: ...cter UPC E Number System Character Do not transmit UPC E Number System Character Transmit UPC E Minimum Reads This feature specifies the minimum number of consecutive times a UPC E label must be decod...

Страница 107: ...ble When disabled the reader will not read EAN 13 JAN 13 bar codes EAN 13 Disable EAN 13 Enable EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13...

Страница 108: ...Flag 1 character is the first character of the label EAN 13 Flag 1 Char Don t transmit EAN 13 Flag 1 Char Transmit EAN 13 ISBN Conversion This option enables disables conversion of EAN 13 JAN 13 Bookl...

Страница 109: ...ith 977 to ISSN labels ISSN Disable ISSN Enable EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read E...

Страница 110: ...Disable When disabled the reader will not read EAN 8 JAN 8 bar codes EAN 8 Disable EAN 8 Enable EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8...

Страница 111: ...d EAN 8 to EAN 13 Disable Expand EAN 8 to EAN 13 Enable EAN 8 Both Guards Substitution Enables disables the ability of the reader to find an EAN JAN8 guard pattern in caseswhere the EAN JAN8 margin ma...

Страница 112: ...rwise full strike EAN 8 segment EAN 8 Guard Insertion Disable EAN 8 Guard Insertion Enable EAN 8 Guard Substitution Enables disables the ability of the reader to substitute guard pattern for even pari...

Страница 113: ...EAN JAN8 label segment in order for the reader to accept the segment for decoding EAN 8 Minimum Segment Length Block 5 EAN 8 Minimum Segment Length Block 6 EAN 8 Minimum Segment Length Block 7 EAN 8...

Страница 114: ...AN 8 Minimum Segment Length Block continued C8BSB0B EAN 8 Minimum Segment Length Block 11 C8BSB0C EAN 8 Minimum Segment Length Block 12 C8BSB0D EAN 8 Minimum Segment Length Block 13 C8BSB0E EAN 8 Mini...

Страница 115: ...inimum Reads This feature specifies the minimum number of consecutive times an EAN 8 Jan 8 label must be decoded before it is accepted as good read EAN 8 Minimum Reads 1 EAN 8 Minimum Reads 2 EAN 8 Mi...

Страница 116: ...label halves being stitched together to assemble a complete label must have the structure GddddC and CddddG EAN 8 Stitch Unlike Label Halves Enables disables the abiliy to stitch EAN 8 label halves to...

Страница 117: ...ill not read EAN two label bar codes EAN Two Label Disable EAN Two Label Enable EAN Two Label Combined Transmission This feature enables disables transmission of an EAN two label pair as one label The...

Страница 118: ...Label Minimum Reads This feature specifies the minimum number of consecutive times an EAN two label bar code must be decoded before it is accepted as good read EAN 8 Minimum Reads 1 EAN 8 Minimum Read...

Страница 119: ...ture description UPC EAN Decoding Level Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See De...

Страница 120: ...combine label data from multiple scans when decoding Enabling correlation will help the reader read labels that have some spots and or voids It may also help read labels that have damaged areas Enabli...

Страница 121: ...n Enable 5 digit price weight check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation Price Weight Check Disab...

Страница 122: ...BT21X1 UPC A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as good read UPC A Minimum Reads 1 UPC A Minimum Reads 2 U...

Страница 123: ...nsertion Enable The segment must have the structure GddddddCdddddd or ddddddCddddddG UPC EAN Stitch Exact Label Halves Enables disables the ability to stitch exact UPC A EAN 13 label halves with no ov...

Страница 124: ...he ability to stitch two UPC A EAN 13 label halves together that may have differing characters in them NOTE UPC EAN Stitch Unlike Label Halves Disable UPC EAN Stitch Unlike Label Halves Enable The lab...

Страница 125: ...AN label segment in order for the reader to accept the segment for decoding UPC EAN Minimum Segment Length Block 5 UPC EAN Minimum Segment Length Block 6 UPC EAN Minimum Segment Length Block 7 UPC EAN...

Страница 126: ...QBT21X1 UPC EAN Global Settings continued CUNSL0B UPC EAN Minimum Segment Length Block 11 CUNSL0C UPC EAN Minimum Segment Length Block 12 CUNSL0D UPC EAN Minimum Segment Length Block 13 CUNSL0E UPC EA...

Страница 127: ...lowing add ons supple mentals P2 P5 GS1 128 NOTE Optional Add Ons Disable P2 Optional Add Ons Enable P2 Optional Add Ons Disable P5 If a UPC EAN base label and a an add on are both decoded the reader...

Страница 128: ...rogramming Mode Add Ons 118 QuickScan I QD21X1 QM21X1 QBT21X1 Optional Add ons continued CADO501 Optional Add Ons Enable P5 CADO800 Optional Add Ons Disable GS1 128 CADO801 Optional Add Ons Enable GS1...

Страница 129: ...ion sets the time the reader will look for an add on when an add on fragment has been seen and optional add ons are enabled Optional Add on Timer 10ms Optional Add on Timer 20ms Optional Add on Timer...

Страница 130: ...1 QBT21X1 Optional Add On Timer continued CADOT06 Optional Add on Timer 60ms CADOT07 Optional Add on Timer 70ms CADOT0A Optional Add on Timer 100ms CADOT0C Optional Add on Timer 120ms CADOT0E Optional...

Страница 131: ...s This feature specifies the minimum number of times a P2 add on must be read before it is marked as valid and then combined with a base label P2 Add Ons Minimum Reads 1 P2 Add Ons Minimum Reads 2 P2...

Страница 132: ...eads This feature specifies the minimum number of times a P5 add on must be read before it is marked as valid and then combined with a base label P5 Add Ons Minimum Reads 1 P5 Add Ons Minimum Reads 2...

Страница 133: ...ture specifies the minimum number of times an GS1 128 add on must be read before it is marked as valid and then combined with a base label GS1 128 Add Ons Minimum Reads 1 GS1 128 Add Ons Minimum Reads...

Страница 134: ...le When disabled the reader will not read GS1 DataBar Omnidirectional bar codes GS1 DataBar Omnidirectional Disable GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Emulation Whe...

Страница 135: ...inimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read GS1 DataBar Omnidirectional Minimum Reads 1 GS1 DataBar Omnidirectional Minimu...

Страница 136: ...d Enable Disable When disabled the reader will not read GS1 DataBar Expanded bar codes GS1 DataBar Expanded Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 128 Emulation When enabled GS1...

Страница 137: ...pecifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good read GS1 DataBar Expanded Minimum Reads 1 GS1 DataBar Expanded Minimum Reads...

Страница 138: ...riable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding t...

Страница 139: ...n page 128 Mode or the first fixed length if in Fixed Length on page 128 Mode Length includes the bar code s data characters only The length can be set from 1 to 74 characters See Set Length 1 on page...

Страница 140: ...ond fixed length if in Fixed Length on page 128 Mode Length includes the bar code s data characters only The length can be set from 1 to 74 characters A setting of 00 specifies to ignore this length o...

Страница 141: ...Disable When disabled the reader will not read GS1 DataBar Limited bar codes GS1 DataBar Limited Disable GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBar Limit...

Страница 142: ...is feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read GS1 DataBar Limited Minimum Reads 1 GS1 DataBar Limited Mini...

Страница 143: ...ng Mode Product Reference Guide 133 Code 39 The following options apply to the Code 39 symbology Code 39 Enable Disable When disabled the reader will not read Code 39 bar codes Code 39 Disable Code 39...

Страница 144: ...en disabled any check character in the label is treated as a data character Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calculate Std Check Code 39 Check Ch...

Страница 145: ...e data Code 39 Check Character Transmission Don t Send Code 39 Check Character Transmission Send Code 39 Start Stop Character Transmission Enable this option to enable disable transmission of Code 39...

Страница 146: ...ickScan I QD21X1 QM21X1 QBT21X1 Code 39 Full ASCII In Code 39 decoding this enables disables the translation of Code 39 charac ters to Code 39 full ASCII characters Code 39 Full ASCII Disable Code 39...

Страница 147: ...areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label CC3LO01 Code 39 Quiet Zones Quiet Zone on one side CC3LO02 Code 39 Quiet Zones Quiet Zo...

Страница 148: ...Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read Code 39 Minimum Reads 1 Code 39 Minimum Reads 2 Code 39...

Страница 149: ...ogy decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed programming instruc tions Code 39 Decoding Level 1 C...

Страница 150: ...riable length decoding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding tw...

Страница 151: ...140 Mode or the first fixed length if in Fixed Length on page 140 Mode Length includes the bar code s data characters only The length can be set from 0 to 50 characters See Set Length 1 on page 306 fo...

Страница 152: ...Mode Length includes the bar code s check data and full ASCII shift charac ters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 00 specifie...

Страница 153: ...specifies the ratio between an intercharacter space and module for Code 39 labels Code 39 Interdigit Ratio Disable Code 39 Interdigit Ratio 1 Code 39 Interdigit Ratio 2 Code 39 Interdigit Ratio 3 Code...

Страница 154: ...ickScan I QD21X1 QM21X1 QBT21X1 Code 39 Interdigit Ratio continued CC3IR06 Code 39 Interdigit Ratio 6 CC3IR07 Code 39 Interdigit Ratio 7 CC3IR08 Code 39 Interdigit Ratio 8 CC3IR09 Code 39 Interdigit R...

Страница 155: ...will also increase the chances that a label will be read incorrectly Code 39 Character Correlation Disable Code 39 Character Correlation Enable Code 39 Stitching This option enables disables stitching...

Страница 156: ...reader will not read Code 32 bar codes Code 32 Disable Code 32 Enable Code 32 Feature Setting Exceptions NOTE The following features are set for Code 32 by using these Code 39 set tings Code 39 Quiet...

Страница 157: ...code data Code 32 Check Character Transmission Don t Send Code 32 Check Character Transmission Send Code 32 Start Stop Character Transmission This option enables disable transmission of Code 32 start...

Страница 158: ...9 CIP symbology Code 39 CIP Enable Disable Enables Disables ability of the reader to decode Code 39 CIP labels Code 39 CIP Disable Code 39 CIP Enable Code 128 The following options apply to the Code 1...

Страница 159: ...8 label shall be set to Code 39 and all Code 39 formatting control shall be applied to the label Code 128 to Code 39 Don t Expand Code 128 to Code 39 Expand Code 128 Check Character Transmission Enabl...

Страница 160: ...and 4 Code 128 Function Character Transmission Don t Send Code 128 Function Character Transmission Send Code 128 Sub Code Change Transmission Enables disables the transmission of Sub Code exchange cha...

Страница 161: ...blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zones Quiet Zone on one side C...

Страница 162: ...Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read Code 128 Minimum Reads 1 Code 128 Minimum Reads 2 Code...

Страница 163: ...y decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed programming instruc tions Code 128 Decoding Level 1 Co...

Страница 164: ...iable length decoding or fixed length decoding for the Code 128 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding tw...

Страница 165: ...154 Mode or the first fixed length if in Fixed Length on page 154 Mode Length includes the bar code s data characters only The length can be set from 1 to 80 characters See Set Length 1 on page 306 f...

Страница 166: ...ength if in Fixed Length on page 154 Mode Length includes the bar code s data characters only The length can be set from 1 to 80 characters A setting of 00 specifies to ignore this length only one fix...

Страница 167: ...relation will also increase the chances that a label will be read incorrectly Code 128 Character Correlation Disable Code 128 Character Correlation Enable Code 128 Stitching This option enables disabl...

Страница 168: ...option enables disables the ability of the reader to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128...

Страница 169: ...uct Reference Guide 159 Interleaved 2 of 5 I 2 of 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2 of 5 bar codes I 2 of 5 Dis...

Страница 170: ...is treated as a data character I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calculation Check German Parcel I 2...

Страница 171: ...heck Character Transmission Don t Send I 2 of 5 Check Character Transmission Send I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decode...

Страница 172: ...evels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed program...

Страница 173: ...le length decoding or fixed length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two d...

Страница 174: ...gth Mode or the first fixed length if in Fixed Length Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters in increments of two See Set Lengt...

Страница 175: ...Length Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters in increments of two A setting of 0 specifies to ignore this length only one fixe...

Страница 176: ...p read labels that have damaged areas Enabling correlation will also increase the chances that a label will be read incorrectly I 2 of 5 Character Correlation Disable I 2 of 5 Character Correlation En...

Страница 177: ...reader s software and the data will be decoded if all bar code proofing requirements are met I 2 of 5 Stitching Disable I 2 of 5 Stitching Enable Interleaved 2 of 5 CIP HR The following options apply...

Страница 178: ...the reader will not read Datalogic 2 of 5 bar codes Datalogic 2 of 5 Disable Datalogic 2 of 5 Enable Datalogic 2 of 5 Check Character Calculation This option enables disables calculation and verifica...

Страница 179: ...mission Don t Send Datalogic 2 of 5 Check Character Transmission Send Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 label must be de...

Страница 180: ...alogic 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum a...

Страница 181: ...ngth if in Fixed Length Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters in increments of two Length includes the bar code s data charact...

Страница 182: ...d length if in Fixed Length on page 163 Mode The length includes the bar code s check and data characters The length can be set from 2 to 50 characters A setting of 00 specifies to ignore this length...

Страница 183: ...imum ratio between intercharacter space and module for Datalogic 2 of 5 Datalogic 2 of 5 Interdigit Maximum Ratio 1 Datalogic 2 of 5 Interdigit Maximum Ratio 2 Datalogic 2 of 5 Interdigit Maximum Rati...

Страница 184: ...5 Interdigit Maximum Ratio continued CD2IR06 Datalogic 2 of 5 Interdigit Maximum Ratio 6 CD2IR07 Datalogic 2 of 5 Interdigit Maximum Ratio 7 CD2IR08 Datalogic 2 of 5 Interdigit Maximum Ratio 8 CD2IR09...

Страница 185: ...ase the chances that a label will be read incorrectly Datalogic 2 of 5 Character Correlation Disable Datalogic 2 of 5 Character Correlation Enable Datalogic 2 of 5 Stitching This option enables disabl...

Страница 186: ...it Programming Mode Codabar 176 QuickScan I QD21X1 QM21X1 QBT21X1 Codabar Codabar Enable Disable When disabled the reader will not read Codabar bar codes Codabar Disable Codabar Enable CCBEN00 CCBEN01...

Страница 187: ...ional Codabar check character When disabled any check characters in the label are treated as data character Codabar Check Character Calculation Don t Calculate Codabar Check Character Calculation Enab...

Страница 188: ...code data Codabar Check Character Transmission Don t Send Codabar Check Character Transmission Send Codabar Start Stop Character Transmission Enable this option to enable disable transmission of Codab...

Страница 189: ...Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar Check Character Set abcd tn e Codabar Check Character Set abcd abcd Codabar Start Stop Character Match When enabled this option requires th...

Страница 190: ...ank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label Codabar Quiet Zones Quiet Zone on one side Codabar Quiet Zones Quiet Zones on two si...

Страница 191: ...nimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read Codabar Minimum Reads 1 Codabar Minimum Reads 2 Codabar Mi...

Страница 192: ...very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed programming instruc tions Codabar Decoding Level Disable Codabar Deco...

Страница 193: ...ble length decoding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two d...

Страница 194: ...Fixed Length on page 183 Mode Length includes the bar code s start stop check and data characters The length must include at least one data character The length can be set from 3 to 50 characters in...

Страница 195: ...h includes the bar code s start stop check and data charac ters The length must include at least one data character The length can be set from 3 to 50 characters in increments of two A setting of 00 s...

Страница 196: ...re specifies the ratio between an intercharacter space and module for Codabar labels Codabar Interdigit Ratio Disable Codabar Interdigit Ratio 1 Codabar Interdigit Ratio 2 Codabar Interdigit Ratio 3 C...

Страница 197: ...Product Reference Guide 187 Codabar Interdigit Ratio continued CCBIR06 Codabar Interdigit Ratio 6 CCBIR07 Codabar Interdigit Ratio 7 CCBIR08 Codabar Interdigit Ratio 8 CCBIR09 Codabar Interdigit Rati...

Страница 198: ...g correlation will also increase the chances that a label will be read incorrectly Codabar Character Correlation Disable Codabar Character Correlation Enable Codabar Stitching This option enables disa...

Страница 199: ...Codabar Enable Disable Enables Disables ability of reader to decode ABC Codabar labels ABC Codabar Disable ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between St...

Страница 200: ...Dynamic Concatenation Mode ABC Codabar Dynamic Concatenation Timeout 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec ABC Codabar Dynamic Concatenation Timeout 200 msec ABC Codabar Dynamic...

Страница 201: ...ing with D to be concatenated ABC Codabar Force Concatenation Disable ABC Codabar Force Concatenation Enable Code 11 The following options apply to the Code 11 symbology Code 11 Enable Disable When di...

Страница 202: ...lculation Disable Code 11 Check Character Calculation Check C Code 11 Check Character Calculation Check K Code 11 Check Character Calculation Check C and K Code 11 Check Character Transmission This fe...

Страница 203: ...nimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read Code 11 Minimum Reads 1 Code 11 Minimum Reads 2 Code 11 Mi...

Страница 204: ...riable length decoding or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding tw...

Страница 205: ...he first fixed length if in Fixed Length on page 194 Mode Length includes the bar code s check and data characters The length can be set from 2 to 50 characters in increments of two See Set Length 1 o...

Страница 206: ...h if in Fixed Length on page 194 Mode Length includes the bar code s check and data characters The length can be set from 2 to 50 characters A setting of 00 specifies to ignore this length only one fi...

Страница 207: ...specifies the ratio between an intercharacter space and module for Code 11 labels Code 11 Interdigit Ratio Disable Code 11 Interdigit Ratio 1 Code 11 Interdigit Ratio 2 Code11 Interdigit Ratio 3 Code...

Страница 208: ...ickScan I QD21X1 QM21X1 QBT21X1 Code 11 Interdigit Ratio continued CC1IR06 Code 11 Interdigit Ratio 6 CC1IR07 Code 11 Interdigit Ratio 7 CC1IR08 Code 11 Interdigit Ratio 8 CC1IR09 Code 11 Interdigit R...

Страница 209: ...ogy decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed programming instruc tions Code 11 Decoding Level 1 C...

Страница 210: ...ng correlation will also increase the chances that a label will be read incorrectly Code 11 Character Correlation Disable Code 11 Character Correlation Enable Code 11 Stitching This option enables dis...

Страница 211: ...reader will not read Standard 2 of 5 bar codes Standard 2 of 5 Disable Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation This option enables disables calculation and verification of a...

Страница 212: ...aracter Transmission Don t Send Standard 2 of 5 Check Character Transmission Send Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label m...

Страница 213: ...of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximu...

Страница 214: ...h on page 203 Mode or the first fixed length if in Fixed Length on page 203 Mode Length includes the bar code s check and data characters The length can be set from 1 to 50 characters See Set Length 1...

Страница 215: ...th if in Fixed Length on page 203 Mode Length includes the bar code s check and data characters The length can be set from 1 to 50 characters A setting of 00 specifies to ignore this length only one f...

Страница 216: ...also increase the chances that a label will be read incorrectly Standard 2 of 5 Character Correlation Disable Standard 2 of 5 Character Correlation Enable Standard 2 of 5 Stitching This option enables...

Страница 217: ...ability of reader to decode Industrial 2 of 5 labels Industrial 2 of 5 Disable Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verification of a...

Страница 218: ...5 Check Character Transmission Enable Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology Variable Leng...

Страница 219: ...e first fixed length if in Fixed Length Mode Length includes the bar code s data characters only The length can be set from 1 to 50 characters and includes check and data characters See Set Length 1 o...

Страница 220: ...Mode Length includes the bar code s check data and full ASCII shift characters The length can be set from 1 to 50 characters The length includes check and data characters A setting of 00 specifies to...

Страница 221: ...ture specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read Industrial 2 of 5 Minimum Reads 1 Industrial 2 of 5 Minimum Reads 2...

Страница 222: ...itching for Industrial 2 of 5 Industrial 2 of 5 Stitching Disable Industrial 2 of 5 Stitching Enable Industrial 2 of 5 Character Correlation Enable disables character correlation for Industrial 2 of 5...

Страница 223: ...Enables Disables the ability of the reader to decode IATA labels IATA Disable IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of IATA Industrial 2 of 5 chec...

Страница 224: ...ncatenation of 2 labels ISBT 128 Concatenation Disable ISBT128 Concatenation Enable ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic ISBT 128 Concatenation Mode...

Страница 225: ...ncatenation Mode ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic Concatenation Timeout 5...

Страница 226: ...ed NOTE ISBT 128 Force Concatenation Disable ISBT 128 Force Concatenation Enable This option is only valid when ISBT 128 Concatenation on page 214 is enabled see page 11 214 ISBT 128 Advanced Concaten...

Страница 227: ...labels MSI Disable MSI Enable MSI Check Character Calculation Enables Disables calculation and verification of an optional MSI check charac ter MSI Check Character Calculation Disable MSI Check Charac...

Страница 228: ...Character Transmission Enable MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology Variable Length For variable length decoding a m...

Страница 229: ...8 Mode or the first fixed length if in Fixed Length on page 218 Mode Length includes the bar code s data characters only The length can be set from 01 to 50 characters See Set Length 1 on page 306 for...

Страница 230: ...Length includes the bar code s check data and full ASCII shift characters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 0 specifies to i...

Страница 231: ...1 MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read MSI Minimum Reads 1 MSI Minimum Reads 2 MSI Minimum R...

Страница 232: ...er to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed programming instruc tions MSI Decoding Level Disable MSI Deco...

Страница 233: ...e 93 Disable Code 93 Enable Code 93 Check Character Calculation Enables disables calculation and verification of an optional Code 93 check character Code 93 Check Character Calculation Disable Code 93...

Страница 234: ...3 Check Character Transmission Enable Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For variable leng...

Страница 235: ...224 Mode or the first fixed length if in Fixed Length on page 224 Mode Length includes the bar code s data characters only The length can be set from 01 to 50 characters See Set Length 1 on page 306 f...

Страница 236: ...ode Length includes the bar code s check data and full ASCII shift charac ters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 00 specifies...

Страница 237: ...nimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read Code 93 Minimum Reads 1 Code 93 Minimum Reads 2 Code 93 Mi...

Страница 238: ...very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed programming instruc tions Code 93 Decoding Level Disable Code 93 Deco...

Страница 239: ...s disables fixed length stitching for Code 93 Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Quiet Zone on one side Code 93 Quiet Zones Quiet Zones on two sides Code 93 Quiet Zones Auto Code 9...

Страница 240: ...le fixed or variable length stitching for Code 93 Code 93 Stitching Disable Code 93 Stitching Enable Code 93 Character Correlation Enables disables Character Correlation for Code 93 Code 93 Character...

Страница 241: ...block F Enable Disable Enables Disables the ability of the reader to decode Codablock F labels Codablock F Disable Codablock F Enable Codablock F EAN Enable Disable Enables Disables the Codablock F EA...

Страница 242: ...heck AIM compliant Codablock F Length Control This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology Variable Length For variable length decoding...

Страница 243: ...e 232 Mode or the first fixed length if in Fixed Length on page 232 Mode Length includes the bar code s data characters only The length can be set from 003 to 255 characters See Set Length 1 on page 3...

Страница 244: ...2 Mode Length includes the bar code s check data and full ASCII shift charac ters The length does not include start stop characters The length can be set from 3 to 255 characters A setting of 00 speci...

Страница 245: ...ble Enables Disables ability of reader to decode Code 4 labels Code 4 Disable Code 4 Enable Code 4 Check Character Transmission This feature enables disables transmission of an optional Code 4 check c...

Страница 246: ...n of hexadecimal label data to dec imal label data Code 4 Hex to Decimal Conversion Disable Code 4 Hex to Decimal Conversion Enable Code 5 The following options apply to the Code 5 symbology Code 5 En...

Страница 247: ...e 5 check charac ter Code 5 Check Character Transmission Don t Send Code 5 Check Character Transmission Send Code 5 Hex to Decimal Conversion This feature enables disables the conversion of hexadecima...

Страница 248: ...de symbology decoder to be very aggressive to very conservative depending on customer needs See Decoding Levels on page 305 for more detailed programming instructions NOTE Code 4 and Code 5 Decoding L...

Страница 249: ...feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read Code 4 or Code 5 Minimum Reads 1 Code 4 or Code 5 Minimum Reads 2...

Страница 250: ...y Follett 2 of 5 Enable Disable Enables Disables ability of reader to decode Follett 2 of 5 labels Follett 2 of 5 Disable Follett 2 of 5 Enable BC412 The following options apply to the BC412 symbology...

Страница 251: ...label is treated as a data character BC412 Check Character Calculation Don t Calculate BC412 Check Character Calculation Calculate Check Character BC412 Minimum Reads This feature specifies the minimu...

Страница 252: ...o be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 305 for more detailed programming instruc tions BC412 Decoding Level Disable BC412 Deco...

Страница 253: ...iable length decoding or fixed length decoding for the BC412 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two d...

Страница 254: ...243 Mode or the first fixed length if in Fixed Length on page 243 Mode Length includes the bar code s data characters only The length can be set from 01 to 50 characters See Set Length 1 on page 306...

Страница 255: ...Length includes the bar code s check data and full ASCII shift characters The length does not include start stop characters The length can be set from 1 to 50 characters A setting of 00 specifies to i...

Страница 256: ...Plessey 246 QuickScan I QD21X1 QM21X1 QBT21X1 Plessey The following options apply to the Plessey symbology Plessey Enable Disable Enables Disables ability of reader to decode Plessey labels Plessey Di...

Страница 257: ...essey Check Character Calculation Enable Plessey std check char verification Plessey Check Character Calculation Enable Anker check char verification Plessey Check Character Calculation Enable Plessey...

Страница 258: ...ifies either variable length decoding or fixed length decoding for the Plessey symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed len...

Страница 259: ...les for setting Length 1 See page 306 for detailed instructions on setting this feature Table 3 Plessey Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15...

Страница 260: ...ifies to ignore this length only one fixed length Table 4 provides examples for setting Length 2 See page 307 for detailed instructions on setting this feature Table 4 Plessey Length 2 Setting Example...

Страница 261: ...nimum Reads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read Plessey Minimum Reads 1 Plessey Minimum Reads 2 Plessey Mi...

Страница 262: ...a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See page 305 for more informa tion on this feature Plessey Decoding Level Disable Ples...

Страница 263: ...es fixed length stitching for Plessey Plessey Stitching Disable Plessey Stitching Enable Plessey Character Correlation Enables disables Character Correlation for Plessey Plessey Character Correlation...

Страница 264: ...Symbologies 254 QuickScan I QD21X1 QM21X1 QBT21X1 NOTES...

Страница 265: ...Erase Batch Memory on page 264 RF Batch Mode Transmit Delay on page 265 DIRECT RADIO AUTOLINK starting on page 266 BLUETOOTH ONLY FEATURES starting on page 267 Source Radio Address Transmission on pag...

Страница 266: ...Good Transmission Beep indication When enabled a beep occurs when a Label is correctly transmitted to the base Beep Frequency Adjusts radio specific beep indications to sound at a low medium or high f...

Страница 267: ...eep Duration This feature controls the duration of beep indications Beep Duration 60 msec Beep Duration 80 msec DEFAULT Beep Duration 100 msec Beep Duration 120 msec Beep Duration 140 msec Beep Durati...

Страница 268: ...ecific beep indications There are three selectable volume levels Beep Volume Low Beep Volume Medium Beep Volume High Disconnect Beep Enables disables the beep indication NOTE STAR default Disconnect B...

Страница 269: ...d when the handheld goes out of range This is especially use ful in instances where the reader might inadvertently have been placed in a bag or cart For this mode to be effective the reader must be li...

Страница 270: ...Programming Mode 260 QuickScan I QD21X1 QM21X1 QBT21X1 Leash Alarm continued Leash Alarm 3 Seconds Leash Alarm 4 Seconds Leash Alarm 5 Seconds Leash Alarm 10 Seconds Leash Alarm 25 Seconds Leash Alarm...

Страница 271: ...to application hardware and or con figuration Automatic Configuration Update Disable Automatic Configuration Update Enable Copy Configuration to Scanner Scan the following label to copy the current Ba...

Страница 272: ...when the Auto Configuration Update feature is disabled and you want a one time configuration update to be performed on the Base Station Copy Configuration to Base Station NOTE Do not scan an ENTER EXI...

Страница 273: ...t of range and is disconnected from the remote device Manual The handheld will always store labels to Flash memory The user must manually send the stored labels to the remote device using a special ba...

Страница 274: ...1 QBT21X1 Erase Batch Memory When the scanner is configured in Manual Batch Mode use the following bar code to erase any labels stored in batch memory NOTE Erase Batch Memory Do not scan an ENTER EXIT...

Страница 275: ...10 msec increments between transmitting labels stored in batch memory RF Batch Mode Transmit Delay No Delay RF Batch Mode Transmit Delay 50 mS RF Batch Mode Transmit Delay 100 mS RF Batch Mode Transm...

Страница 276: ...QM21X1 QBT21X1 DIRECT RADIO AUTOLINK This feature enables disables the ability to link a wireless handheld to a base station without scanning the Unlink label first Direct Radio Link Unlink Label Requ...

Страница 277: ...to be transmit ted to the host and if so at what position with respect to the label data See page 308 in References for detailed information and examples for setting this feature NOTE Source Radio Add...

Страница 278: ...he entry string You can then start again at the beginning CANCEL This feature only applies if Source Radio Address Transmission on page 267 is enabled Link Timeout This feature specifies the wait time...

Страница 279: ...vant bar code from Set PIN Code on page 270 then scan the desired alphanumeric characters from the keypad in Appendix D to set the PIN code See page 310 in References for more detailed information and...

Страница 280: ...xadecimal using the ASCII Chart on the inside back cover of this manual See page 310 for detailed information and examples for setting this feature Set 4 character BT Pin Code To configure this featur...

Страница 281: ...c or Variable Pin Code when BT HID profile is configured Use Static PIN Code DEFAULT Use Variable PIN Code BT HID ALT Mode This feature Enables Disables the ability to transmit correctly a label conte...

Страница 282: ...barcode reader will toggle the on screen vir tual keyboard BT Friendly Name You can set a meaningful name for QuickScan QBT2131 that will appear in the application during device discovery To set a new...

Страница 283: ...eference Guide 273 OTHER BT FEATURES BT Poll Rate This feature specifies the time between BT polls BT Poll Rate Maximum BT Poll Rate BT Poll Rate 10 ms BT Poll Rate 20 ms DEFAULT BT Poll Rate 50 ms BT...

Страница 284: ...Timeout feature sets the time for automatically switching the unit off when the imager has been idle Powerdown Timeout Disable Powerdown Timeout 10 minutes Powerdown Timeout 20 minutes Powerdown Time...

Страница 285: ...e hand held reader and Base Station is considered failed When setting this parameter take into consideration the radio traffic number of readers in the same area The selectable range for this feature...

Страница 286: ...rom host scanner signals a good transmission as soon as the Base Station has sent the label to the host and host has replied with an acknowledge message ACK from cradle ACK when sent to host ACK from...

Страница 287: ...ASCII character The CR character cannot be contained in the middle Messages cannot start with or because these are reserved for Service mode command Base station can receive host message only if Host...

Страница 288: ...ed in combination with the Beeper The LED and Beeper will be controlled by the system after the entire command sequence is interpreted Example ESC 6 q ESC 3 q ESC 7 q Turns on the green LED emits a go...

Страница 289: ...page 289 DATA EDITING on page 290 DATA EDITING OVERVIEW on page 290 GLOBAL PREFIX SUFFIX on page 291 GLOBAL AIM ID on page 292 LABEL ID PRE LOADED SETS on page 293 LABEL ID SET INDIVIDUALLY PER SYMBO...

Страница 290: ...e appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan th...

Страница 291: ...red character value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT ACK CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from...

Страница 292: ...character value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from the...

Страница 293: ...Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character 6...

Страница 294: ...D Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Program...

Страница 295: ...for the desired character value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT DISABLE CHARACTER SETTING 5 Scan the appropriate two alpha numeric...

Страница 296: ...he hex equivalent for the desired character value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT ENABLE CHARACTER SETTING 5 Scan the appropriate...

Страница 297: ...WEDGE QUIET INTERVAL SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indicat...

Страница 298: ...ING on page 36 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the...

Страница 299: ...the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This complet...

Страница 300: ...will be transmitted before the scanned bar code data OR NOTE Additional advanced editing is available See the Advanced Formatting features in the Datalogic Aladdin Configuration Application or contact...

Страница 301: ...ver of this manual to find the hex value assigned to the desired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 bar codes from Appendix D...

Страница 302: ...th scanned bar code data AIM label identifiers consist of three characters as follows A close brace character ASCII followed by A code character see the table below followed by A modifier character th...

Страница 303: ...000 CODE11 CE 434500 b 620000 CODE128 230000 T 540000 CODE32 A 410000 X 580000 CODE39 2A0000 V 560000 CODE4 4 340000 4 340000 CODE5 j 6A0000 j 6A0000 DATALOGIC 2OF5 s 730000 s 730000 EAN13 F 460000 B...

Страница 304: ...0 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI 400000 Z 5A0000 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 470000 UPCA P8 A 410000 Q 510000 UPCE E...

Страница 305: ...o the ASCII Chart on page 349 on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a La...

Страница 306: ...n starting on page 64 GS1 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII table inside back co...

Страница 307: ...ed More examples of Label ID settings are provided in Table 16 4 The reader will save the string and exit Programming Mode when the ENTER EXIT baqr code is scanned a second time or the hex values for...

Страница 308: ...e desired string Sixteen positions must be determined as in the above example Next turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill...

Страница 309: ...code SELECT LABEL GONE TIMEOUT SETTING 5 Scan the appropriate three alpha numeric characters from the keypad in Appendix D Keypad representing the duration which was determined in the steps above You...

Страница 310: ...appropriate three digits from the keypad in Appendix D Keypad representing the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the...

Страница 311: ...r Pulse Multiple When the trigger is pulled continuous scanning is acti vated until Scanning Active Time on page 86 has elapsed or the trigger has been released and pulled again Double Read Timeout on...

Страница 312: ...present the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This...

Страница 313: ...in Appendix D Keypad rep resenting the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to...

Страница 314: ...Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character 6 Scan the ENTER EXIT PROGRAMMING MODE bar code to ex...

Страница 315: ...ense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of prod uct labels to be decoded There are many factors that determine when to ch...

Страница 316: ...h 1 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the length setting which was determined in the steps above You will hear a...

Страница 317: ...r Program ming Mode 3 Scan the Select Length 2 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the length setting which was de...

Страница 318: ...rmine the desired character then find its hexadecimal equivalent on the ASCII Chart on the inside back cover A setting of 00 specifies no delim iter character 2 Go to page 268 and scan the ENTER EXIT...

Страница 319: ...Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character 6...

Страница 320: ...cter 7 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See Table 26 for some examples of how to set this feature Table 26 BT Pin Code Setting Exampl...

Страница 321: ...ypical 140 mA Operating max 380 mA Idle standby typical 50 mA N A Battery Type N A Li Ion battery pack Typical charge time for full charge from full discharge N A 6 hours with Host Power through the m...

Страница 322: ...t 20 C label inclination 10 Item QD2131 QM QBT21X1 Decode Capability UPC EAN JAN A E 13 8 UPC EAN JAN including P2 P5 UPC EAN JAN including ISBN Bookland ISSN UPC EAN Coupons Code 39 including full AS...

Страница 323: ...2483 5 MHz Range in open air N A 25 m typical User Environment Operating Tem perature 32 to 122 F 0 to 50 C Charging Temperature N A 32 to 104 F 0 to 40 C Storage Tem perature 40 to 70 C 40 to 158 F...

Страница 324: ...p Latch To Host Cable Cable Strain Relief Bottom of Imager Interface Cable Port Pin 1 Pin 10 The signal descriptions in Table 27 apply to the connector on the reader and are for reference only Table 2...

Страница 325: ...d Read When to Indi cate The reader will beep once at current frequency volume mono bi tonal setting and duration upon a successful label scan ROM Failure There is an error in the reader s software pr...

Страница 326: ...e Label Program ming Mode Acceptance of Programming Configuration option s have been successfully pro grammed via labels and the reader has exited Program ming Mode N A Reader sounds one high fre quen...

Страница 327: ...and programming bar codes for each parameter A column has also been pro vided for recording of your preferred default settings for these same configu rable features Table 28 Standard Defaults Paramete...

Страница 328: ...Control Characters Disable Wedge Quiet Interval 100ms Intercode Delay 100 ms USB Keyboard Speed 1 ms USB OEM USB OEM Device Usage Handheld Scanner USB OEM Interface Options Ignore Data Editing Global...

Страница 329: ...l next trigger pull Scan Mode Trigger Single Stand Mode Triggered Timeout 0 5 Seconds Scanning Active Time 5 Seconds Stand Mode Flash Disable Flash On Time 1 Second Flash Off Time 600 ms Green Spot Du...

Страница 330: ...N 8 Check Character Transmission Send Expand EAN 8 to EAN 13 Disable EAN 8 Both Guards Substitution Disable EAN 8 Guard Insertion Disable EAN 8 Guard Substitution Disable EAN 8 Minimum Segment Length...

Страница 331: ...1 DataBar Omnidirectional Minimum Reads 1 GS1 DataBar Expanded GS1 DataBar Expanded Enable Disable Disable GS1 DataBar Expanded GS1 128 Emulation Disable GS1 DataBar Expanded Minimum Reads 1 GS1 DataB...

Страница 332: ...eck Character Transmission Don t Send Code 32 Start Stop Character Transmission Don t Transmit Code 39 CIP Code 39 CIP Enable Disable Disable Code 128 Code 128 Enable Disable Enable Expand Code 128 to...

Страница 333: ...c 2 of 5 Enable Disable Enable Datalogic 2 of 5 Check Character Calculation Disable Datalogic 2 of 5 Check Character Transmission Don t Send Datalogic 2 of 5 Minimum Reads 2 Datalogic 2 of 5 Length Co...

Страница 334: ...catenation Mode Static ABC Codabar Dynamic Concatenation Timeout 200mS ABC Codabar Force Concatenation Disable Code 11 Code 11 Enable Disable Disable Code 11 Check Character Calculation Check C and K...

Страница 335: ...Enable Industrial 2 of 5 Length Control Variable Industrial 2 of 5 Set Length 1 1 Character Industrial 2 of 5 Set Length 2 50 Characters Industrial 2 of 5 Minimum Reads 1 Read Industrial 2 of 5 Stitch...

Страница 336: ...93 Minimum Reads 1 Read Code 93 Decoding Level Level 3 Code 93 Quiet Zones Auto Code 93 Stitching Enable Code 93 Character Correlation Enable Codablock F Codablock F Enable Disable Disable Codablock...

Страница 337: ...ength Control Variable Length BC412 Set Length 1 1 Character BC412 Set Length 2 50 Characters Plessey Plessey Enable Disable Disable Plessey Check Character Calculation Enable Plessey std check char v...

Страница 338: ...rce Radio Address Delimiter Character No Delimiter Character BT Security Features 2 seconds BT Security Mode Disable Select PIN Code Length Select4 characterBT PIN Code Set PIN Code 31323334 Default P...

Страница 339: ...Character s K GS1 128 Label ID Character s P Datalogic 2 of 5 Label ID Character s H ISBT 128 Label ID Character s K UPCE P2 Label ID Character s C UPCE P5 Label ID Character s C UPCE GS1 128 Label ID...

Страница 340: ...acter s R Code 11 Label ID Character s b Code 128 Label ID Character s T GS1 128 Label ID Character s k UPCA P2 Label ID Character s F UPCA P5 Label ID Character s G UPCA GS1 128 Label ID Character s...

Страница 341: ...r codes in this appendix are typical representations for their symbology types UPC A EAN 13 3 456789 012340 Code 39 0 12345 67890 5 123ABC Code 128 Interleaved 2 of 5 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7...

Страница 342: ...332 QuickScan I QD21X1 QM21X1 QBT21X1 Code 32 Codabar Code 93 Code 11...

Страница 343: ...taBar RSS on page 333 GS1 DataBar 14 10293847560192837465019283746029478450366523 GS1 DataBar Expanded Stacked 1234890hjio9900mnb GS1 DataBar Expanded 08672345650916 GS1 DataBar Limited 55432198673467...

Страница 344: ...334 QuickScan I QD21X1 QM21X1 QBT21X1 NOTES...

Страница 345: ...Product Reference Guide 335 Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4...

Страница 346: ...336 QuickScan I QD21X1 QM21X1 QBT21X1 5 6 7 8 9...

Страница 347: ...Product Reference Guide 337 A B C D E F...

Страница 348: ...338 QuickScan I QD21X1 QM21X1 QBT21X1 NOTES...

Страница 349: ...aracter Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII tab...

Страница 350: ...X C S B ETX C S C EOT C S D ENQ C S E ACK C S F BEL C S G BS HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C...

Страница 351: ...5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H...

Страница 352: ...A 091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A...

Страница 353: ...112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 01...

Страница 354: ...AB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C...

Страница 355: ...acter is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl Cl BS Tab S Tab Enter Keypd Enter Ins 1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L...

Страница 356: ...K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0...

Страница 357: ...x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F...

Страница 358: ...D21X1 QM21X1 QBT21X1 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy components of Microsoft Windows in English and some other...

Страница 359: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Страница 360: ...OR 97402 USA Telephone 1 541 683 5700 Fax 1 541 345 7140 2015 2017 Datalogic S p A and or its affiliates All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p...

Отзывы: