background image

Technical Specifications

Quick Reference Guide

23

DECODE CAPABILITY

1D BAR CODES 

GS1 Databar linear codes, UPC/EAN (A,E,13,8), UPC/EAN with P2/
P5 Addons, UPC/EAN Coupons, ISBN, Code128, EAN128, ISBT128, 
Code39, Code39 Full ASCII, Code39 CIP, Code 32, Codabar, Inter-
leaved 2 of 5, IATA, Industrial 2 of 5, Standard 2 of 5, Code11, MSI, 
Plessey, Code 93, Follet 2/5

2D / STACKED CODES 

DataMatrix, MaxiCode and QR Codes(QR, Micro QR and Multiple QR 
codes), Aztec
- Postal codes including:
 Australian Post, China Post, Japanese Post, KIX Post, Planet Code, 
Postnet, Royal Mail Code(RM45CC), IMB 
- stacked codes including EAN/JAN Composites; GS1 Databar Com-
posites, GS1 Databar Expanded Stacked; GS1 DataBar Stacked; GS1 
DataBar Stacked Omnidirectional; MacroPDF; Micro PDF417; 
PDF417; UPC A/E Composites, French CIP13, Grid Matrix(Chinese) 
code

Interfaces Supported

RS-232, Keyboard Wedge, and USB. 
See page 5 for a listing of available inter-
face options. 

USER ENVIRONMENT

Operating Tempera-
ture

-4° to 122° F (-20°   -   +50° C )

Storage Temperature

-40° to 158° F (-40° to 70° C)

Humidity 

0 to 95% non-condensing

Drop Specifications

Scanner withstands >50 times 6.5' (2 m)  
drops to concrete

Ambient Light Immu-
nity 

100,000 Lux 

Contaminants: Spray/
rain, 
Dust/particulates

IP65

ESD Level

20 KV

Beeper/Speaker

>= 80 dB  @ 10 cm 

REGULATORY

See Regulatory Addendum

Содержание PowerScan PD9530-RT

Страница 1: ...PowerScan Retail PD9530 RT Industrial Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...

Страница 2: ...ou can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate medi...

Страница 3: ...yboard Interface 8 Country Mode 9 Caps Lock State 13 Numlock 14 Programming 14 Using Programming Bar Codes 14 Configure Other Settings 15 Resetting Product Defaults 15 Reading Parameters 16 Good Read...

Страница 4: ...ii PowerScan Retail PM9500 RT...

Страница 5: ...r information implementation tech niques and trade secrets related to the Software b any other trade secrets marked appropriately or identified as proprietary or confidential and c any information tha...

Страница 6: ...on 5 2 End User shall not disclose provide or otherwise make available the Propri etary Information of Datalogic or its third party licensors to any person other than End User s authorized employees o...

Страница 7: ...International Sale of Goods shall not apply to this Agreement 10 Termination 10 1Either party may terminate this Agreement or any license granted under this Agreement at any time upon written notice i...

Страница 8: ...er state country or territory in which End User resides or in which any of End User s assets are located In the event an action is brought to enforce the terms and conditions of this Agreement the pre...

Страница 9: ...imply aim the reader and pull the trigger Since the PowerScan PD9530 RT is a power ful omni directional reader the orientation of the symbol is not important Decoding Thanks to powerful algorithms Pow...

Страница 10: ...ower supply via the Interface Cable supplied with a power jack Autoscanning An autoscan command causes the reader to scan continuously and to monitor the central zone of its reading area Flash Memory...

Страница 11: ...the Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Cover along th...

Страница 12: ...of view indicated by the aiming system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should...

Страница 13: ...rovided in this section For defaults and addi tional information associated with each interface proceed to the corresponding chapter in the PowerScan PD9530 RT PRG Configuring the Interface Scan the a...

Страница 14: ...face Type 6 PowerScan Retail PD9530 RT RS 232 RS 232 standard interface RS 232 RS 232 Wincor Nixdorf RS232 WN RS 232 for use with OPOS UPOS JavaPOS RS 232 OPOS USB USB Com to simulate RS 232 standard...

Страница 15: ...ued USB OEM can be used for OPOS UPOS JavaPOS USB OEM a Download the correct USB Com driver from www datalogic com USB Keyboard with standard key encoding USB KBD USB Keyboard with alternate key encod...

Страница 16: ...ntrol character emulation for keyboard inter faces Keyboard Interface KEYBOARD WEDGE IBM AT or PS 2 PCs Standard Key Encoding KBD AT IBM AT or PS 2 PCs Standard Key Encoding without external keyboard...

Страница 17: ...ted by the keyboard This option is usable only with USB KBD and Keyboard Wedge interface without the Alternate Key mode COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium C...

Страница 18: ...D9530 RT COUNTRY MODE continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces listed i...

Страница 19: ...Guide 11 COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces lis...

Страница 20: ...PowerScan Retail PD9530 RT COUNTRY MODE continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the...

Страница 21: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected ENTER EXIT PROGRAMMING MODE Caps...

Страница 22: ...is factory configured with a set of standard default features After scanning the interface bar code from the Interfaces section select other options and cus tomize your reader through use of the progr...

Страница 23: ...ion Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installation requires different programming than the standa...

Страница 24: ...e acquisi tion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance a...

Страница 25: ...Reading Parameters Quick Reference Guide 17 Digital Watermark Reading ENTER EXIT PROGRAMMING MODE Disable Enable...

Страница 26: ...ents undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has ela...

Страница 27: ...motion is detected Motionix motion sensing technology Scan the Enter Exit Programming bar code above then either of the barcodes below ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode T...

Страница 28: ...d or transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically dis abled Multiple Label Reading...

Страница 29: ...cteristics User Environment and Regulatory infor mation Item Description PHYSICAL CHARACTERISTICS Dimensions Height 212 mm Length 110 mm Width 74 mm Weight without cable 330 gr without cable ELECTRICA...

Страница 30: ...m reflectance Resolution Max resolution 1D 4 mils Max resolution 2D 7 5 mils DEPTH OF FIELD TYPICAL A Symbology Working Ranges Code 39 4 mils 6 17 cm 20 mils 4 55 cm 40 mils 4 85 cm EAN 13 13 mils 4 4...

Страница 31: ...il Code RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Com posites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional MacroPDF Micro PDF417 PDF417...

Страница 32: ...der beeps four times at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configu rable via the featu...

Страница 33: ...label the soft ware shall turn the green spot on for the time specified by the configured value N A N A Image Cap ture When ready to capture image Blue light flashes 2 times when updating N A a Except...

Страница 34: ...Label Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N...

Страница 35: ...eld Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes bee...

Страница 36: ...mance during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alco...

Страница 37: ...d from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defects...

Страница 38: ...r window in accordance with product manual v any defect or damage caused by natural or man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusiv...

Страница 39: ...roduct to Customer Datalogic will select the carrier but Datalogic shall not thereby assume any liability in connection with the return shipment Ergonomic Recommendations Reduce or eliminate repetitiv...

Страница 40: ...General Duty Handheld Scanners category link From this page you can select your product model from the drop down list which gives you access to Downloads including Data Sheets Manuals Software Utiliti...

Страница 41: ...Quick Reference Guide 33 NOTES...

Страница 42: ...34 PowerScan Retail PD9530 RT...

Страница 43: ......

Страница 44: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 68...

Отзывы: