Enter/Exit Programming Mode
236
PowerScan™ PD953X/PBT950X/PM950X
Changing System Speed
1. Link the PM950X with a BC9xxx Base.
2. With the PM950X, read a “Compatible Mode/Normal Mode Speed” pro-
gramming label on
to set “Low, Medium, or High Speed”.
3. Place the PM950X into the BC9xxx.
The Reader and Base will now be linked at the new programmed speed.
This feature can also be programmed using Datalogic Aladdin.
1. On the BC9xxx Base, change the Compatible mode parameter to low,
intermediate, or high speed through Aladdin.
2. Place an unlinked PM950X onto the BC9xxx base.
The Reader and base will link at the new programmed speed.
Frequency Agility
In exceptionally noisy environments or in case of a high concentration of
radio devices, Star system performance may be improved by configuring
Frequency Agility. Frequency Agility parameters change the way the radio
frequencies are used in a Star communication system.
As when changing the System Speed, use the following procedure:
1. Link the PM950X with a BC9xxx Base.
2. With the PM950X, read one of the “Frequency Agility” programming
labels below.
3. Place the PM950X into the BC9xxx.
Reader and Base will then be linked and the new frequencies handling will be
operational.
DEFAULT
$CSTFA00
Use default fixed channel
$CSTFA80
Enable frequency hopping
The channel is changed automatically
Содержание PowerScan 950X Series
Страница 30: ...Setup 20 PowerScan PD953X PBT950X PM950X NOTES...
Страница 34: ...Configuration Using Bar Codes 24 PowerScan PD953X PBT950X PM950X NOTES...
Страница 56: ...46 PowerScan PD953X PBT950X PM950X NOTES...
Страница 72: ...62 PowerScan PD953X PBT950X PM950X NOTES...
Страница 90: ...Enter Exit Programming Mode 80 PowerScan PD953X PBT950X PM950X NOTES...
Страница 182: ...172 PowerScan PD953X PBT950X PM950X NOTES...
Страница 278: ...268 PowerScan PD953X PBT950X PM950X NOTES...
Страница 316: ...References 306 PowerScan PD953X PBT950X PM950X NOTES...
Страница 320: ...Message Formatting 310 PowerScan PD953X PBT950X PM950X NOTES...
Страница 358: ...Scancode Tables 348 PowerScan PD953X PBT950X PM950X NOTES...