Enter/Exit Programming Mode
126
PowerScan™ PD953X/PBT950X/PM950X
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for
.
Length 1 is the minimum label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. The length includes the bar code’s
check and data characters. The length can be set from 2 to 50 characters in
increments of two.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 8. I 2 of 5 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
2 Characters
6 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
02
06
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 of 5 LENGTH 1 SETTING
5
Scan Two Characters From
‘0’ and ‘2’
‘0’ and ‘6’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L1
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
06 = Length 1 is 6 Characters
Содержание PowerScan 950X Series
Страница 30: ...Setup 20 PowerScan PD953X PBT950X PM950X NOTES...
Страница 34: ...Configuration Using Bar Codes 24 PowerScan PD953X PBT950X PM950X NOTES...
Страница 56: ...46 PowerScan PD953X PBT950X PM950X NOTES...
Страница 72: ...62 PowerScan PD953X PBT950X PM950X NOTES...
Страница 90: ...Enter Exit Programming Mode 80 PowerScan PD953X PBT950X PM950X NOTES...
Страница 182: ...172 PowerScan PD953X PBT950X PM950X NOTES...
Страница 278: ...268 PowerScan PD953X PBT950X PM950X NOTES...
Страница 316: ...References 306 PowerScan PD953X PBT950X PM950X NOTES...
Страница 320: ...Message Formatting 310 PowerScan PD953X PBT950X PM950X NOTES...
Страница 358: ...Scancode Tables 348 PowerScan PD953X PBT950X PM950X NOTES...