DATALOGIC
4
For wall mounting, the cradle is positioned as shown in Figure 3:
Figure 3 - OM-DRAGON™ Base
1.
If you are installing several cradles and you desire to align them, you can use
the alignment plate (see Alignment Plate Installation), otherwise continue
with step 2.
2. Using the mounting holes on the base as a pattern mark the wall where
you desire to mount the OM-DRAGON™.
3.
Drill three appropriate size holes.
4.
Insert the threaded dowels into the holes.
5.
Position the base on the wall and affix it by means of the three screws.
6.
Reattach the cradle body by sliding it along the mounting tabs until aligned.
7.
Fix the cradle to the base by means of the fixing screw. (See Figure 2).
8. Insert the antenna in the appropriate hole on the body of the cradle and
screw it clockwise until tight.
ALIGNMENT PLATE
1.
Referring to Figure 1 and Figure 4, snap the Alignment Plate into the holes
provided on the base so that the plate remains extended from the side of
the base.
2.
Snap the next base onto the remaining pins of the Alignment Plate.
Figure 4 - Alignment Plate