MX-E Series Hardware Guide
SVS-Vistek Cameras (non-IP67 rated)
71
Datalogic S.r.l.
S V S - Vi s t e k ( n o n - I P 6 7 ) C a m e r a C o n n e c t i o n
This camera uses two cables, one for Ethernet and one for power and trigger signals. For the Ether-
net connection, use cable 606-0677-xx. To connect power and trigger signals, use a terminal block
(248-0136) with the optional Hirose 12-pin to HD-15 camera cable (606-0673-xx).
SVS-Vistek Non-IP67 I/O Circuit
eco655MVGE
eco655CVGE
5
No
Yes
2456
2048
10
10.4.0
10.5.0
eco814MT
9
No
3360
2712
7
11.2.1
eco694MT
6
No
2752
2204
10
11.2.1
Terminal
Signal Name
Notes
1 (Wht/Blu)
Camera Ground
2 (Wht/Org)
Camera Power
Min +10 VDC to Max +25 VDC
3 & 4
DO NOT USE
Not Currently Supported
5 (Wht/Grn)
Camera Trigger In
0 to +24 VDC
6
DO NOT USE
Not Currently Supported
7(Gry/Wht)
Trigger Out to Strobe
0 to +24 VDC; 300 mA Max
8, 9, 10, 11, 12
DO NOT USE
Not Currently Supported
Содержание MX-E Series
Страница 1: ...MX E Series Hardware Guide for Processor and Cameras Revision Date July 19 2018...
Страница 4: ......
Страница 18: ...Before You Call MX E Series Hardware Guide Datalogic S r l 12...
Страница 28: ...Battery MX E Series Hardware Guide Datalogic S r l 22...
Страница 44: ...M2xx and M3xx Camera Connection MX E Series Hardware Guide Datalogic S r l 38 M2xxandM3xxTerminalConnections...
Страница 56: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 50 661 0402TerminalBlockDimensions...
Страница 58: ...JAI Cameras MX E Series Hardware Guide Datalogic S r l 52 JAITerminalConnections sinking...
Страница 64: ...Basler Cameras MX E Series Hardware Guide Datalogic S r l 58 TerminalConnections...
Страница 116: ...M1xx and E1xx MX E Series Hardware Guide Datalogic S r l 110...
Страница 120: ...Index MX E Series Hardware Guide Datalogic S r l iv...