MC-P096 is  a  Multi-Slot Battery  Charger  (MBC)  that  allows you to charge the  PowerScan™  PM9600  battery packs.  MC-P096-M2  (Master)  unit  can
charge up to 2 batteries simultaneously and can be extended with maximum 4 MC-P096-E2 (Extension) units to charge up to 10 batteries.
Master unit has a power supply connector to power itself and the connected extension units. Moreover, Master unit has a USB Type-C connector for ser

-

vice purposes and/or to retrieve information on battery packs.
MC-P096-M4 is a MBC configuration consisting of a MC-P096-M2 unit and a MC-P096-E2 unit to allow you to charge up to 4 batteries simultaneously.

Power-On LED

Battery Charging

LED

Removable Cover

Master Unit

Extension Unit

MC-P096-M4

MBC CONFIGURATION

Press to attach/detach 

the slot

MC-P096-M2 UNIT + 4 MC-P096-E2 UNITS

Maximum allowed configuration (4 extension units = 10 batteries)

USING MBC-P096

To attach or detach different units to each other, press on the tab indicated in the figure on the opposite page.

POWER SUPPLY

Datalogic 12V, 5A wall adapter is recommended (90ACC0350) and a standard Power Cord cable is needed to connect the power supply to the socket, e.g.
the following Datalogic P/Ns:

P/N: 6003-0924 Power Cord, 220V, Italy/Chile

P/N: 6003-0941 US Power Cord, 110V, US, Standard

P/N: 6003-0940 Power Cord, AC, IEC/EU

CONNECTIONS

To power the MC-P096, follow the steps below:

1. Plug the power supply cable into the round connector placed on the Master unit;
2. Plug the power cord into the power supply unit;
3. Plug the power cord into a socket.

The Power LED turns on when the unit is correctly powered.

For battery data retrieving, follow the steps below:

1. Plug the USB Type-C cable into the USB port placed on the Master unit.
2. Plug the other side of the USB cable to a Host unit (e.g. a PC with Aladdin application).

CHARGE FUNCTION

Charging process starts automatically as soon as a battery pack is inserted into a free slot.

Battery Charging State - LED Description

The charge takes place slowly if the battery is extremely low.

WARNING: No more than 4 extension units can be supported.

WARNING: Make sure that the Master unit is disconnected from the power supply before starting this operation.

NOTE: It is recommended to use ONLY certified Datalogic P/N 70031180X Removable Battery Pack. Do not attempt to open and/or disassem

-

ble the battery or the battery charger. To achieve the best performances, install and keep the MBC in a clean and cool environment.

CHARGING LED STATE

CHARGING STATE

Off

The LED is off if the slot is empty or, with the battery inside, in case of battery failure

Blinking:
Orange (charge <50%)
Green (charge >50%)

Charging

Solid Green

End of charge

NOTE: Not all types of battery failures can be signaled by the battery charger.