![Datalogic Magellan 800i Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/datalogic/magellan-800i/magellan-800i_reference-manual_512115069.webp)
UPC-A
Product Reference Guide
61
Number System Digit (NSD) Transmission
This feature enables/disables transmission of UPC-A System Number.
UPC-A Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-A label must be
decoded before it is accepted as a good read.
START / END
PROGRAMMING BAR CODES
Disable Number System Digit Transmission
Enable Number System Digit Transmission
DEFAULT
00D300(CR)
00D301(CR)
START / END
PROGRAMMING BAR CODES
Minimum = 1 Read
DEFAULT
Minimum = 2 Reads
Minimum = 3 Reads
Minimum = 4 Reads
006101(CR)
006102(CR)
006103(CR)
006104(CR)