background image

QUICK REFERENCE GUIDE   

3

German GS Safety Certification

The following statement is required for the German GS safety
certification

:

INSTALLATION

Route the interface cable from the terminal or host. Plug the AC adapter
(if one is used) into a wall outlet and the interface (I/F) cable, then route
and attach the I/F cable to the scanner. Verify operation by presenting
known-good bar codes to the scanner. The unit should beep

1

 and/or

flash its good read LED and send the bar code data to the host or
terminal. If not, refer to the Troubleshooting section of this guide.

The Magellan 1500i uses intelligent illumination technology to optimize
light levels for a variety of bar code scanner functions including
automatic reading of bar codes from printed surfaces, mobile devices
and image capture in variable contrast nments.

This product is not intended for use in the immediate or direct visual
field of the display work place. To avoid disturbing reflections on
the display work place, this product shall not be placed in the

immediate or direct field of vision.

1.

Beeper and LED behavior is selectable and may have been disabled by a pre-
vious user.

Connect 

Here

I/F Cable

To Host/Terminal

A/C Adapter
(if needed)

Содержание Magellan 1500i

Страница 1: ...QUICK REFERENCE GUIDE MAGELLAN 1500i Omnidirectional Imaging Scanner BSR idware GmbH Jakob Haringer Str 3 A 5020 Salzburg https www bsr at sales bsr at...

Страница 2: ...oductions of the documentation Electronic versions of this document may be downloaded from the Datalogic website www datalogic com If you visit our website and would like to make comments or sug gesti...

Страница 3: ...ng 4 How to Scan 5 Handheld Scanning Mode 5 Center Zone Qualification 6 Scanner Button 6 Scanner Button Functions 6 LED and Beeper Indicators 8 Programming 10 Service Port Mode 10 Using Barcodes 10 In...

Страница 4: ...iv MAGELLAN 1500I NOTES...

Страница 5: ...g quickly and efficiently For more details including additional programming information reference the Product Reference Guide PRG which is available from the Datalogic website FEATURES Figure 1 Scanne...

Страница 6: ...w the Regulatory Labeling as described on page 4 Labels are shown to illustrate their location only Please view the labels on your product for actual details Power Interface Power interface Cable Latc...

Страница 7: ...not refer to the Troubleshooting section of this guide The Magellan 1500i uses intelligent illumination technology to optimize light levels for a variety of bar code scanner functions including autom...

Страница 8: ...t into the latch release hole as shown in Figure 2 on page 2 2 After removing the Interface Cable pull the bottom of the Stand forward in the direction of the Front Window to detach it from the unit I...

Страница 9: ...it is resting on the counter or in the optional stand or the scanner can be picked up for targeted scanning Figure 4 Scanning Methods Handheld Scanning Mode To read a barcode using Handheld Scanning M...

Страница 10: ...button acts as a trigger to enable the reading of a barcode label PRESS DURATION FUNCTION COMMENT Momentary when scanner is asleep Wakes scanner from Sleep Mode Alternatively the scanner can be awake...

Страница 11: ...system support personnel should perform a reset a By standard default this function is normally disabled to prevent acciden tal activation by users b Users should not perform scanner resets except und...

Страница 12: ...Indicates a bar code has been read and decoded Scanner Ready Constant dim green The scanner is ready for operation Sleep Mode Green LED slowly and continuously changes from off to dim to off The scann...

Страница 13: ...he good read beep indication is configurable Options include Enable disable frequency duration and volume See the Product Reference Guide PRG for more information Diagnostics Varies see Error Codes on...

Страница 14: ...ice Port mode as follows 1 Unplug the unit if needed 2 While Holding down the Scan Button on the top of the unit plug the scanner in 3 The scanner will enter Service Port Mode enabling it to be progra...

Страница 15: ...RS 232 Wincor Nixdorf USB OEM USB Keyboard USB COM Interface NOTE Reference the Product Reference Guide PRG or configuration software such as Datalogic Aladdin or Scanalyzer for additional options Al...

Страница 16: ...pot Duration Successful reading can be signaled by a good read green spot Use the bar codes that follow to specify the duration of the good read pointer beam after a good read START END Disabled i Sho...

Страница 17: ...bile phone barcode reading START END Cell Phone Mode Enable Toggle Cell Phone Mode Enable Always On Cell Phone Mode Enable Timer Expiration 046700 CR 046702 CR DEFAULT 046701 CR BSR idware GmbH Jakob...

Страница 18: ...enabled for this feature to be active NOTE Higher Settings will slow down read performance on printed barcodes START END Cell Mode Frequency Very Low Cell Mode Frequency Low Cell Mode Frequency Mediu...

Страница 19: ...comes on The scanner will power up with limited scanning which will allow you to scan programming labels to reconfigure the scanner to the desired interface No communication with the host Verify the...

Страница 20: ...ode If it is configured to do so the scanner will sound a series of beeps corresponding to the error code and or flash its LED simultaneous to the beeps The table below describes what these codes mean...

Страница 21: ...abrasive mild water based cleaner to wipe away stains smudges fingerprints spills etc from the scan window and exterior surfaces See the next page for a list of Manufacturer Approved Cleaning Material...

Страница 22: ...n with other cleaning agents will void the manufacturer s warranty APPROVED CLEANERS Hydrogen Peroxide not to exceed a 3 solution Chlorine bleach not to exceed a 0 25 solution Mild detergent and water...

Страница 23: ...roduct from Datalogic or until the expiration of the original Warranty Period whichever is longer Datalogic does not guarantee and it is not responsible for the maintenance of damage to or loss of con...

Страница 24: ...ment is to a location within the country in which the Datalogic service center is located Buyer shall be responsible for paying all shipping charges duties taxes and any other charges for products ret...

Страница 25: ...nder this or any other contract between Datalogic and the Buyer and or 2 defer shipment under this or any other contract between the Buyer and Datalogic until such default breach or repudiation is rem...

Страница 26: ...22 MAGELLAN 1500I NOTES...

Страница 27: ......

Страница 28: ...purpose without the express written permis sion of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U...

Отзывы: