DELAY ON setting
The DELAY ON represents the output delay activation after the reference mark has
entered the detection area. The delay avoids the detection of events that occur rapidly.
An example can be a mark with shaded colours (light-dark-light) that can be detected
twice.
Select “dLOn” in the parameter menu to set the DELAY ON function.
The parameter programming is accessed by pressing
.
The previously set delay value appears on the display.
Pressing
or
the delay value is increased or decreased by one step of 1 ms until
a maximum delay of 100ms. Keeping
or
pressed, the delay value is increased or
decreased by incremental steps. The setting of a delay different from zero is signalled by
the DELAY LED on. Press
to confirm the value and return to the parameter menu.
DELAY OFF setting
The DELAY OFF represents the output delay deactivation after the reference target has
left the detection area.
The delay extends the output activation allowing slower system interfacing with sensors
to detect shorter pulses.
Select “dLOF” from the parameter menu to set DELAY OFF function.
The parameter programming is accessed by pressing
.
The previously set delay value appears on the display.
Pressing
or
the delay value is increased or decreased by one step of 1 ms until
a maximum delay of 100ms. Keeping
or
pressed, the delay value is increased or
decreased by incremental steps. The setting of a delay different from zero is signalled by
the DELAY LED on. Press
to confirm the value and return to the parameter menu.
UP/DOWN DISPLAY setting
The selection of the UP/DOWN display sets the reading direction on the
display.
Select “dSUP” or “dSdn” in the parameter menu to set the UP or DOWN
direction.
Press
to switch the reading direction previously set
.
ON/OFF DISPLAY setting
Turn off the display during normal operation to save power consumption.
Setting the OFF mode when the sensor is normally functioning, the display turns
OFF. It turns on for 5s after a keyboard command. Select “dSOn” or “dSOF” in the
parameter menu to set the display ON or OFF.
Press
to switch the display mode previously set.
RESET of default parameters
Select “rSEt” in the parameter menu to reset the default parameters.
The “rSEt” text blinks when pressing
.
Releasing the push-button the sensor returns to normal functioning.
The default reset parameters are:
PARAMETER
DISPLAY
DESCRIPTION
Emission
________
Green
MODE
________
MARK
DARK/LIGHT
mode
________
Light
Threshold
2050
Hysteresis
Medium (Normal)
Delay ON and
OFF
Deactivated
Display
Display UP ON
NOTE: if the parameters are reset before turning the sensor off, when repowered
the “rSEt” text blinks on the display for 3s before returning to normal
visualisation.
Saving parameter set -
“SAVE”
Select “SAVE” to save the parameter setting
The parameters are saved pressing
. The display returns to normal
visualisation after releasing the button.
NOTE: Set the data, the operator exits from the menu using the “SAVE” or
“RESET” function. If these operations are not carried out 30s after the last setting,
the sensor returns to normal mode saving the parameters changed.
ACCESSORY FUNCTIONS
REMOTE INPUT
The REMOTE signals carries out the acquisition functions without using the
push-
button. The REMOTE wire connected to +Vdc is equal to pressing the
push-button.
Whereas, if the REMOTE wire is connected to GND or not connected, it is equal to not
pressing the
push-button.
REMOTE
PUSH-BUTTON
0V
NOT PRESSED
+Vdc
PRESSED
-
The duration of the REMOTE wire connection to +Vdc determines the acquisition
type:
MARK MODE
COLOR MODE
DARK/LIGHT input (only in MARK mode)
The DARK/LIGHT signal allows the operator to select the DARK/LIGHT
operating mode for dynamic detection.
In the LIGHT mode, the output is active with light marks on dark backgrounds.
In the DARK mode, the output is active with dark marks on light backgrounds.
The connection of the DARK/LIGHT wire to Vdc sets the DARK mode.
If connected to 0V or not connected set the LIGHT mode.
DARK/LIGHTT
MODE
0V
LIGHT
+VDC
DARK
DIMENSIONS
TECHNICAL DATA
Power supply:
10
…30 Vdc limit values
Ripple:
2 Vpp max.
Current consumption
(output current excluded):
35 mA max. @ 24 Vdc
Output:
PNP output
30 Vdc max. (short-circuit protection)
Output current:
100 mA max.
Output saturation voltage:
2 V
Response time:
16
s (MARK mode), 100us (COLOR mode)
Switching frequency:
30 kHz (MARK mode), 10KHz (COLOR mode)
Indicators:
4-digit display (GREEN) / OUT LED (YELLOW) /
READY LED (GREEN) / DELAY LED (GREEN)
Push-buttons:
push-buttons : -, SET, +
Delay
0…100 ms programmed
default configuration without delay
Dark/light selection:
Automatic in the target/background detection
selectable via wire in the dynamic detection,
selectable via MENU in the color detection
Operating temperature:
-
10 … 55 °C
Storage temperature:
-
20 … 70 °C
Electric shock protection:
double insulation
Operating distance:
9 mm
Depth of field:
3 mm
Minimum spot dimension:
1.5x5 mm
Emission type:
blue ( 465 nm) / green (520 nm) / red (630 nm)
in MARK mode the selection is automatic
Ambient light rejection:
according to EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10 … 55 Hz frequency,
for each axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shocks for each axis (EN60068-2-
27)
Housing material:
Aluminium
Lens material:
Glass (*)
Mechanical protection:
IP67
Connections:
M12 5-pole connector
Weight:
170 g. max.
AtEx 2014/34/EU:
II 3G EX nA II T6 ;
II 3D EX tD A22 IP67 T85°C
(
*
)
It’s available on request, PMMA plastic lens with 9mm focus.
The sensors are NOT safety devices, therefore they MUST NOT be used in the safety
control of the machines where installed.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2017 Datalogic S.p.A. and/or its affiliates
ALL RIGHTS RESERVED.
Without limiting the rights
under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
821005660 Rev. A
DYNAMIC
DET.
Mark detection
V
cc
REMOTE
GND
>1s
Background detection
REMOTE
GND
4s
V
cc
Dynamic detection
(begin) start
STATIC
DET.
Dynamic detection
end
V
cc
REMOTE
GND
>1s
COLOR
DET.
Color detection