SETTINGS in both modes (WH model)
The sensor hysteresis level can be adjusted.
The “HYSt” text appears on the display by pressing the push-button.
HYSTERESIS SETTING
When the push-button is released, the previously set value blinks.
HIGH HYSTERESIS
NORMAL HYSTERESIS
LOW HYSTERESIS
The level switches by pressing or .
Press the SET push-button to save the new hysteresis value.
PARAMETER SETTING (WH model)
Some parameters can be changed entering the menu: MARK/COLOR mode, NORMALLY
OPEN/CLOSE, DELAY ON, DELAY OFF, outputs type or input selection, display orientation,
powering on/off, job selection and job save, RESET and save setting.
Press and together until the “Menu” text appears.
Releasing the push-buttons, the first MARK/COLOR parameter is displayed.
The parameter list is shown by pressing and :
MARK/COLOR SETTING
The sensor can be configured in MARK or COLOR mode.
Select “MArk” or “COLr” in the parameter menu to switch the mode.
The previously set mode switches by pressing SET.
NORMALLY OPEN/CLOSE SETTING (only in COLOR mode)
The output in COLOR mode can be configured as normally open or normally close.
Select “OPEn” or “CLOS” in the parameter menu to switch the output.
Press SET to switch to the previously set mode.
DELAY ON SETTING
The DELAY ON is the output delay activation after the reference mark has entered the
detection area. The delay avoids the detection of events that occur rapidly. An example can
be a mark with shaded colors (light-dark-light) that can be detected twice.
Select “dLOn” in the parameter menu to set the DELAY ON function.
The parameter programming is accessed by pressing SET.
The previously set delay value appears on the display.
Pressing or the delay value is increased or decreased by one step of 1 ms until
a maximum delay of 100 ms.
Keeping or pressed, the delay value is increased or decreased by incremental
steps. The setting of a delay different from zero is signaled by the DELAY LED on. Press
SET to confirm the value and return to the parameter menu.
DELAY OFF SETTING
The DELAY OFF is the output delay deactivation after the reference mark has left the
detection area. The delay extends the output activation allowing slower system interfacing
with sensors to detect shorter pulses.
Select “dLOF” in the parameter menu to set the DELAY OFF function.
The parameter programming is accessed by pressing SET.
The previously set delay value appears on the display.
Pressing or the delay value is increased or decreased by one step of 1 ms until
a maximum delay of 100 ms.
Keeping or pressed, the delay value is increased or decreased by incremental
steps. The setting of a delay different from zero is signaled by the DELAY LED on. Press
SET to confirm the value and return to the parameter menu.
UP/DOWN DISPLAY SETTING
Selecting UP/DOWN on the display sets the reading direction on the display.
Select “dSUP” or “dSdn” in the parameter menu to set the UP or DOWN direction.
Press SET to switch to the reading direction previously set.
OUT 1 SETTING (WHITE WIRE)
Selecting 1_PP on the display sets the output 1 mode (PP, PNP or input).
Press the SET push-button to switch through the three options.
OUT 0 SETTING (BLACK WIRE)
Selecting 0_PP on the display sets the output 0 mode (PP or PNP).
Press the SET push-button to switch to the OUT 0 setting previously set.