Observation / Diagnostic Parameters
Index
(dec)
Parameter
Object Name
Lenght
Subindex
(offset)
Value/Range
Description
Data Type Access* Remark
0x0028 (40)
Process Data
Input
1 octet
Read last valid Process Data Input from PDin channel
Device
specific
RO
0x0041 (65)
Analog Signal
2 octets
Read analog signal
UIntegerT
RO
0x0052 (82)
Device
Temperature
2 octets
2 octets
2 octets
2 octets
2 octets
1(64)
2(48)
3(32)
4(16)
5(0)
Device temperature actual
Device min. temperature since powerup
Device max. temperature since powerup
Device min. temperature during lifetime
Device max. temperature during lifetime
IntegerT
IntegerT
IntegerT
IntegerT
IntegerT
RO
RO
RO
RO
RO
0x0053 (83)
Device
Temperature
Threshold
2 octets
2 octets
1(16)
2(0)
Device min. temperature threshold
Device max. temperature threshold
IntegerT
IntegerT
R/W
Saved in non-volatile memory every
hour. Events are generated if the device
temperature exceeds the thresholds.
0x0057 (87)
Operating Hours
4 octets
4 octets
4 octets
1(64)
2(32)
3(0)
0...(2^32)-1
Operating Hours: device operating hours. Not resettable by user.
Operating Hours Maintenance: device operating hours, reset on
system command “Confirm Maintenance”.
Operating Hours Power Up: Time in hours since power up.
UIntegerT
UIntegerT
UIntegerT
RO
RO
RO
0x0024 (36)
Device Status
1 octet
0x00 → Device is operating properly
0x01 → Maintenance Required
0x02 → Out of specification
0x03 → Functional Check
0x04 → Failure
Contains current status of the device
UIntegerT
RO
0x0025 (37)
Detailed Device
Status
3 octets
Information about currently pending Events.
Implemented as dynamic list.
UIntegerT
RO
0x0051 (81)
Emitter Status
1 octet
0x00 = Emitter OFF
0x01 = Emitter ON
Contains current statuts of the emitter
BooleanT
RO
0x0059 (89)
RGB selection
(
W03
)
1 octet
0x01 = Red emission
0x02 = Green emission
0x03 = Blue emission
Select emission type
UIntegerT
R/W
Saved in non-volatile memory
0x005A (90)
Frequency
Selection (
U03
)
1 octet
0x00 = 2 kHz (default)
0x01 = 500 Hz
Select frequency
UIntegerT
R/W
0x005E (94)
Delta (
B53, T53
)
1 octet
0 = low (default T53)
1 = medium (default B53)
2 = high
Set the delta between the signal measured on the reflector and the
thresholds. “Low” is preferred for transparent object detection.
UIntegerT
R/W
Saved in non-volatile memory
*RO = read only, WO = write only, R/W = read/write
Teach-in Parameters
Index
(dec)
Parameter
Object Name
Lenght
Subindex
(offset)
Value/Range
Description
Data Type Access* Remark
0x003A (58)
TI Select
1 octet
0x00 = SSC1 (default, C/Q pin and DO
pin)
Selection for Teach-in channel (volatile)
UIntegerT
R/W
C/Q and DO outputs are antivalent.
Teach SSC1 equals to teach SSC2
0x003B (59)
TI Result
1 octet
1(0)
2(4)
3(5)
Teach-in State
Flag SP1 TP1
Flag SP2 TP1
See IO-Link Smart Sensor Profile
UIntegerT
BooleanT
BooleanT
RO
0x003C (60)
SSC1 Param
2 octets
2 octets
1(16)
2(0)
U03
: 220...1950 (default = 512)
W03
: 220...1950 (default = 1280)
T53
: 181...1950 (default = 196)
B53
: 215...1950 (default = 215)
Not used
Switching threshold
UIntegerT
R/W
Saved in non-volatile memory
Setting a higher threshold
reduces the operating distance
progressively to 0 (output always
active)
0x003D (61)
SSC1 Config
1 octet
1 octet
1(24)
2(16)
0x00: High Active (default
U03
)
0x01: Low Active (default
W03, T53, B53
)
0x01: Single Point (default)
C/Q pin configuration
UIntegerT
UIntegerT
R/W
Saved in non-volatile memory
2 octets
3(0)
0 = low hysteresis (default)
1 = medium hysteresis
2 = high hysteresis
UIntegerT
0x003E (62)
SSC2 Param
2 octets
2 octets
1(16)
2(0)
U03
: 220...1950 (default = 512)
W03
: 220...1950 (default = 1280)
T53
: 181...1950 (default = 196)
B53
: 215...1950 (default = 215)
Non used
Switching threshold
UIntegerT
R/W
Saved in non-volatile memory
Setting a higher threshold
reduces the operating distance
progressively to 0 (output always
active)
0x003F (63)
SSC2 Config
1 octet
1 octet
1(24)
2(16)
0x00: High Active (default
W03, T53, B53
)
0x01: Low Active (default
U03
)
0x01: Single Point (default)
DO pin configuration
UIntegerT
UIntegerT
R/W
Saved in non-volatile memory
2 octets
3(0)
0 = low hysteresis (default)
1 = medium hysteresis
2 = high hysteresis
UIntegerT
0x0040 (64)
Sensitivity
selection
1 octet
0 ..7 Sensitivity
U03
default = 3
W03
default = 5
T53
default = 7
B53
default = 7
Sensitivity
UIntegerT
R/W
Saved in non-volatile memory