background image

Symbologies

Enter/Exit Programming Mode

Product Reference Guide

        

                

   215

BC412 Set Length 2

This feature specifies one of the bar code lengths for 

BC412 Length Control on 

page 214

. Length 2 is the maximum label length if in 

Variable Length on page 

214

 Mode, or the second fixed length if in 

Fixed Length on page 214

 Mode. 

Length includes the bar code’s check, data, and full-ASCII shift characters. The 

length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to 

ignore this length (only one fixed length). See 

"Set Length 2" 

on page 247 for 

more detailed programming instructions.

Select BC412 Length 2 Setting

To configure this feature, scan the ENTER/EXIT bar code 
above, then the bar code at left followed by digits from 
the Alphanumeric characters in 

Appendix D, Key-

pad

 representing your desired character(s). End by 

scanning the ENTER/EXIT bar code again.

Make a mistake? Scan the CANCEL bar code to abort and 
not save the entry string. You can then start again at the 
beginning.

CANCEL

DEFAULT

50 = Length 2 is 50 Characters

$CBCL2

~

Содержание Heron HD3130

Страница 1: ...Heron HD3130 Linear Imager Product Reference Guide...

Страница 2: ...s appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electronic versions...

Страница 3: ...ngs 15 Configuring Other Features 15 Software Version Transmission 15 CONFIGURATION USING BAR CODES 17 Configuration Parameters 17 Global Interface Features 19 Host Commands Obey Ignore 19 USB Suspend...

Страница 4: ...Select Audio Jingle for Power up Event 67 Select Audio Jingle for Good Read Event 68 Select Audio Jingle for Enter Stand Mode 69 Select Audio Jingle for Exit Stand Mode 70 Select Audio Jingle for Tran...

Страница 5: ...S1 DataBar Omnidirectional 105 GS1 DataBar Omnidirectional Enable Disable 105 GS1 DataBar Omnidirectional GS1 128 Emulation 105 GS1 DataBar Omnidirectional Minimum Reads 106 GS1 DataBar Expanded 107 G...

Страница 6: ...Set Length 2 144 I 2 of 5 Zero Pattern 144 Interleaved 2 of 5 CIP HR 145 Interleaved 2 of 5 CIP HR Enable Disable 145 Datalogic 2 of 5 146 Datalogic 2 of 5 Enable Disable 146 Datalogic 2 of 5 Check Ch...

Страница 7: ...th 1 181 Industrial 2 of 5 Set Length 2 182 Industrial 2 of 5 Minimum Reads 183 IATA 184 IATA Enable Disable 184 IATA Check Character Transmission 184 ISBT 128 185 ISBT 128 Concatenation 185 ISBT 128...

Страница 8: ...7 RS 232 Parameters 218 RS 232 Only 218 RS 232 USB COM Parameters 219 Keyboard Interface 226 Wedge Quiet Interval 226 Intercharacter Delay 227 Intercode Delay 228 Data Format 229 Data Editing 229 Glob...

Страница 9: ...CANCODE TABLES 279 Control Character Emulation 279 Single Press and Release Keys 279 Interface Type PC AT PS 2 or USB Keyboard 280 Interface Type PC AT PS 2 Alt Mode or USB Keyboard Alt Mode 282 Micro...

Страница 10: ...viii Heron HD3130 NOTES...

Страница 11: ...ined tune uploaded via Datalogic Aladdin configuration software instead of the normal beep tone Using the Heron Reader Heron readers automatically scan barcodes at a distance Simply aim and pull the t...

Страница 12: ...des to print Overview Chapter 1 Introduction provides a product overview unpacking instructions and cable connection information Chapter 2 Setup presents information about unpacking and setting up the...

Страница 13: ...r returning products for repair Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller A reseller is acquainted with specific types...

Страница 14: ...Introduction 4 Heron HD3130 NOTES...

Страница 15: ...Follow the steps provided in this section to connect and get your scanner up and communicating with its host 1 Connect the Interface Cable at the scanner as shown in Figure 2 To dis connect the cable...

Страница 16: ...communicate with a standard or Wincor Nixdorf W N RS 232 host RS 232 OPOS This interface is used for OPOS UPOS JavaPOS systems Keyboard Wedge Connection The Keyboard Wedge cable has a Y connection fr...

Страница 17: ...to the Host USB Keyboard Wedge RS 232 NOTE Specific cables are required for connection to different hosts The connec tions illustrated in Figure 3 are examples only Actual connectors may vary from th...

Страница 18: ...Place the mask at the desired position of the stand base on the desk Screws Rubber Feet 3 Use a pen to mark the location of the small holes shown in red on the desk surface Remove the mask before inst...

Страница 19: ...Into Stand Place the reader into the stand taking care to insert the handle into the stand clip as shown Correct insertion will be signaled by a beep then the reader will be ready to read bar codes U...

Страница 20: ...o change the inclination of the reader while in the stand To adjust the stand 1 With fingers loosen the screw on the bottom of the stand by turning it counterclockwise Screw 2 Set the stand upright an...

Страница 21: ...eyboard Wedge Configuring the Interface Scan the programming bar code from the following section which selects the appropriate interface type to match the system the scanner will be connected to Next...

Страница 22: ...RS 232 Wincor Nixdorf RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS Select USB COM STDa a Download the correct USB Com driver from www datalogic com USB Com to simulate RS 232 standard inte...

Страница 23: ...out external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT Select KBD AT ALT NK Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external...

Страница 24: ...nstructions carefully when configuring each given programmable feature Datalogic Aladdin Utility Programming can alternatively be performed using the Datalogic Aladdin Configuration application which...

Страница 25: ...e starting on page 47 Configuring Other Features If your installation requires different programming than the standard factory default settings the following sections of this manual allow configuratio...

Страница 26: ...restore the Factory Configuration you have two options You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below Both labels restore the scann...

Страница 27: ...your application The following configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group Interface Configuration RS 232 ONLY In...

Страница 28: ...ut parameters are needed go to Appendix D Keypad and scan the appropriate characters from the keypad NOTE Additional information about many features can be found in the Ref erences chapter If you make...

Страница 29: ...his manual HOST COMMANDS OBEY IGNORE on page 19 USB SUSPEND MODE on page 20 Host Commands Obey Ignore This option specifies whether the scanner will obey or ignore host commands When set to ignore the...

Страница 30: ...t Programming Mode 20 Heron HD3130 USB Suspend Mode This setting enables disables the ability of the USB interface to enter suspend mode DEFAULT USB Suspend Mode Disable USB Suspend Mode Enable CUSSE0...

Страница 31: ...32 USB COM Interfaces BAUD RATE on page 21 PARITY on page 23 STOP BITS on page 22 HANDSHAKING CONTROL on page 24 RS 232 Standard Factory Settings Reference Appendix B Standard Defaults for a listing o...

Страница 32: ...the receiving device for the next charac ter in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommo date Set the n...

Страница 33: ...e according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are...

Страница 34: ...CTS RTS is asserted during transmissions CTS gates transmis sions RTS XON XOFF RTS is asserted during transmissions CTS is ignored XON and XOFF gate transmissions RTS On CTS RTS is always asserted CTS...

Страница 35: ...26 BEEP ON ASCII BEL on page 27 BEEP ON NOT ON FILE on page 27 ACK NAK OPTIONS on page 28 ACK CHARACTER on page 29 NAK CHARACTER on page 29 ACK NAK TIMEOUT VALUE on page 30 ACK NAK RETRY COUNT on page...

Страница 36: ...ets on page 232 for more detailed program ming instructions Intercharacter Delay No Delay Select Intercharacter Delay Setting To configure this feature scan the ENTER EXIT bar code above then the bar...

Страница 37: ...serial line BEL is issued to gain a user s attention to an illegal entry or other important event Beep On ASCII BEL Disable DEFAULT Beep On ASCII BEL Enable Beep On Not on File This option enables dis...

Страница 38: ...le for label transmission The scanner expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge The scanner will respond with ACK NAK when the host sends a com...

Страница 39: ...th normal operation of these char acters 8 bit data is not recognized when the option Stop Bits on page 22 has been set as 7 Data Bits NAK Character This setting specifies an ASCII character or hex va...

Страница 40: ...e ACK NAK Timeout Value on page 222 for more detailed programming instructions Select ACK NAK Timeout Value Setting To configure this feature scan the ENTER EXIT bar code above then the bar code at le...

Страница 41: ...mited retries See ACK NAK Retry Count on page 223 for more detailed program ming instructions Select ACK NAK Retry Count Setting To configure this feature scan the ENTER EXIT bar code above then the b...

Страница 42: ...ected while waiting for an ACK character from the host Options are Ignore errors detected Process error as valid ACK character Process error as valid NAK character DEFAULT ACK NAK Error Handling Ignor...

Страница 43: ...nsmission Failure Enable Indication DEFAULT Disable Character Specifies the value of the RS 232 host command used to disable the scanner ASCII characters or any hex value from 0 to 0xFF can be selecte...

Страница 44: ...er ASCII characters or any hex value from 0 to 0xFF can be selected See Enable Character on page 225 for more detailed programming instructions NOTE Select Enable Character Setting DEFAULT 0x45 Enable...

Страница 45: ...sting of standard factory settings Information about control character emula tion which applies to keyboard interfaces is listed in Appendix E Scancode Tables COUNTRY MODE on page 36 CAPS LOCK STATE o...

Страница 46: ...ported by the keyboard The Country Mode setting is ignored if the interface uses alternate key encod ing DEFAULT Country Mode U S Country Mode Belgium Country Mode Britain Country Mode Croatia Country...

Страница 47: ...y Mode Japanese 106 key Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Keyboard Interface Enter Exit Programming Mode Product Reference Guide 37 Country Mode contin...

Страница 48: ...ry Mode 38 Heron HD3130 Country Mode continued Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode Switzerland Country Mode French Canadian Country Mode Lithuania CKBCO0F CKBCO09...

Страница 49: ...oard is selected This does not apply to USB Keyboard DEFAULT Caps Lock State Caps Lock OFF Caps Lock State Caps Lock ON Caps Lock State AUTO Caps Lock Enable Numlock This option specifies the setting...

Страница 50: ...pad 40 Heron HD3130 Keyboard Numeric Keypad This feature specifies if numeric characters will be sent using the standard keys or the numeric keypad DEFAULT Keyboard Numeric Keypad Standard Keys Keyboa...

Страница 51: ...cial keys are available in the range from 81H to A1 Send Ctrl Shift Key The behavior is the same as above but control keys are sent in the format Ctrl Shift Keys Send Special Function Key Send charact...

Страница 52: ...or more detailed programming instructions NOTE Select Wedge Quiet Interval Setting To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Al...

Страница 53: ...Delay on page 227 for more detailed programming instructions Intercharacter Delay No Delay Select Intercharacter Delay Setting To configure this feature scan the ENTER EXIT bar code above then the ba...

Страница 54: ...led programming instructions Set Intercode Delay To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix...

Страница 55: ...USB poll rate for a USB Keyboard NOTE DEFAULT USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keyboard Speed 3ms USB Keyboard Speed 5ms USB Keyboard Speed 7ms USB Keyboard Speed 10ms This feature a...

Страница 56: ...Keyboard Interface 46 Heron HD3130 NOTES...

Страница 57: ...es differ depending upon which host type the scanner will be connected with Use the feature settings in this chapter to spe cifically configure for the USB OEM interface Other USB interfaces are inclu...

Страница 58: ...cate Options are Tabletop Scanner Handheld Scanner NOTE USB OEM Device Usage Tabletop Scanner USB OEM Device Usage Handheld Scanner DEFAULT It may be necessary to switch device usage when connecting t...

Страница 59: ...page 53 Label ID Control on page 53 Label ID Symbology Selection on page 54 CASE CONVERSION on page 60 CHARACTER CONVERSION on page 60 Product Reference Guide 49 Data Format The features in this chapt...

Страница 60: ...digits from the Alphanumeric characters in Appendix D Keypad repre senting your desired character s End by scanning the ENTER EXIT bar code again Set Global Prefix Set Global Suffix To configure this...

Страница 61: ...ed bar code data See Global AIM ID on page 231 for more detailed programming instructions DEFAULT Global AIM ID Disable Global AIM ID Enable GS1 128 AIM ID If Global AIM ID is disabled the AIM ID for...

Страница 62: ...bology on page 53 If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 51 Label ID Pre load...

Страница 63: ...dividually Per Symbology on page 234 for more detailed programming instructions Label ID Control This option controls whether a Label ID is disabled or sent as a prefix or suffix for a given symbology...

Страница 64: ...ID is to be configured See Label ID Set Individually Per Symbology on page 234 Set UPC A Label ID Character s Set UPC A P2 Label ID Character s Set UPC A P5 Label ID Character s Set UPC E Label ID Cha...

Страница 65: ...l ID Symbology Selection continued C3BID Set EAN 13 Label ID Character s C32ID Set EAN 13 P2 Label ID Character s C35ID Set EAN 13 P5 Label ID Character s C8BID Set EAN 8 Label ID Character s C82ID Se...

Страница 66: ...nued C4BID Set GS1 DataBar Omnidirectional Label ID Character s CXBID Set GS1 DataBar Expanded Label ID Character s CLBID Set GS1 DataBar Limited Label ID Character s CC3ID Set Code 39 Label ID Charac...

Страница 67: ...t Code 128 Label ID Character s CU8ID Set GS1 128 Label ID Character s CI2ID Set Interleaved 2 of 5 Label ID Character s CHRID Set Interleaved 2 of 5 CIP HR Label ID Character s CD2ID Set Datalogic 2...

Страница 68: ...el ID Character s CS2ID Set Standard 2 of 5 Label ID Character s CU2ID Set Industrial 2 of 5 Label ID Character s CINID Set ISSN Label ID Character s CIAID Set IATA Label ID Character s CI8ID Set Conc...

Страница 69: ...mbology Selection continued CCFID Set Codablock F Label ID Character s CCRID Set Code 4 Label ID Character s CC5ID Set Code 5 Label ID Character s CF2ID Set Follett 2 of 5 Label ID Character s CISID S...

Страница 70: ...ix Suffix or other appended data Character Conversion Character conversion is an eight byte configuration item The eight bytes are 4 character pairs represented in hexadecimal ASCII values The first c...

Страница 71: ...DIO JINGLE FOR POWER UP EVENT on page 67 RGB AUTO DELAY on page 79 SELECT AUDIO JINGLE FOR GOOD READ EVENT on page 68 SCAN MODE on page 80 GOOD READ WHEN TO INDICATE on page 72 STAND MODE TRIGGERED TI...

Страница 72: ...e symbology and data If the unit reads a label and sees the same label again within the Double Read Timeout the second read of the label will be ignored Double Read Time out does not apply to scan mod...

Страница 73: ...3 Double Read Timeout continued CSNDR32 Double Read Timeout 0 5 Second CSNDR3C Double Read Timeout 0 6 Second CSNDR46 Double Read Timeout 0 7 Second CSNDR50 Double Read Timeout 0 8 Second CSNDR5A Doub...

Страница 74: ...a trigger pull for each label that is read See Label Gone Timeout on page 237 for more detailed program ming instructions Select Label Gone Timeout Setting To configure this feature scan the ENTER EXI...

Страница 75: ...7 0 0 0 or later on your computer 2 Connect the scanner you want to program to the computer 3 Use Device Autodetection to allow Aladdin to search for your reader or click on Offline Configuration to s...

Страница 76: ...laddin configuration soft ware or traditional beep sounds to indicate good read See below for parameters to define which preloaded Jingle to sound upon power up or good read events Additional items su...

Страница 77: ...specify which of the Jingles 1 15 or the built in sound will be used to indicate scanner power up The built in default sound for power up is Dialtone wav Select Audio Jingle on Power up To configure t...

Страница 78: ...ility use this setting to designate which of the Jingles 1 15 will be sounded when the scanner performs a good read Select Audio Jingle on Good Read To configure this feature scan the ENTER EXIT bar c...

Страница 79: ...guration utility use this setting to designate which of the Jingles 1 15 will be sounded when the scanner enters Stand Mode Select Audio Jingle on Enter Stand Mode To configure this feature scan the E...

Страница 80: ...n utility use this setting to designate which of the Jingles 1 15 will be sounded when the scanner exits Stand Mode Select Audio Jingle on Exit Stand Mode To configure this feature scan the ENTER EXIT...

Страница 81: ...ation utility use this setting to designate which of the Jingles 1 15 will be sounded when the scanner performs a good read Select Audio Jingle on Tx Error event To configure this feature scan the ENT...

Страница 82: ...cessfully reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then activ NOTE This option which uses CTS is only...

Страница 83: ...Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high fre quency selectable from the list below Controls the speaker s pitch tone CBPTY00 Good Read Beep Type Mono...

Страница 84: ...me Selects the speaker volume loudness upon a good read Jingle or beep There are three selectable volume levels Good Read Speaker Volume Speaker Off Good Read Speaker Volume Low Good Read Speaker Volu...

Страница 85: ...Length Specifies the duration of a good read beep CBPLE06 Good Read Beep Length 60 msec CBPLE08 Good Read Beep Length 80 msec CBPLE0A Good Read Beep Length 100 msec CBPLE0C Good Read Beep Length 120 m...

Страница 86: ...lue LEDs which are used to indicate Good Read and Auto Presentation Mode colors change when Scanner is in Idle mode Enable Disable RGB LED Enable Disable RGB LED as a good read indicator RGB LED Disab...

Страница 87: ...state See RGB Good Read Raising Falling Time on page 238 for more detailed program ming instructions Set RGB Good Read Raising Time To configure this feature scan the ENTER EXIT bar code above then th...

Страница 88: ...e a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 14 20 seconds Falling Time RGB Good Read Holding Time Specifies how...

Страница 89: ...bled See RGB Auto Delay Time on page 240 for more information Set RGB Auto Delay To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alph...

Страница 90: ...an Mode See Scan Mode on page 241 for more detailed programming instructions Scan Mode Trigger Single DEFAULT Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan M...

Страница 91: ...ed while in Stand Mode NOTE This timeout is only used when the Scan Mode is configured as Stand Mode CSNOT01 Stand Mode Triggered Timeout 0 5 Seconds CSNOT03 Stand Mode Triggered Timeout 1 5 Seconds C...

Страница 92: ...r code at left followed by digits from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT bar code again Make a mistake Scan the CANC...

Страница 93: ...e detailed pro gramming instructions Select Flash ON Time Setting To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric charac...

Страница 94: ...code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT bar code again Make a...

Страница 95: ...146 UPC E on page 90 Codabar on page 153 EAN 13 on page 93 ABC Codabar on page 164 EAN 13 on page 93 JAN 13 Code 11 on page 166 EAN 8 on page 96 JAN 8 Standard 2 of 5 on page 174 Add Ons on page 101 I...

Страница 96: ...ly UPC EAN coupon decoding Enable only GS1 DataBar enables only GS1 DataBar coupon decoding To set this feature 1 Scan the Enter Exit bar code 2 Scan either the enable or disable bar code below You ll...

Страница 97: ...sable When disabled the scanner will not read UPC A bar codes UPC A Disable UPC A Enable DEFAULT UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A...

Страница 98: ...symbology ID to match those required for EAN 13 DEFAULT UPC A to EAN 13 Don t Expand UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables disables transmission of th...

Страница 99: ...ed before it is accepted as good read In store labels are defined as UPC A labels with a number system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 l...

Страница 100: ...n disabled the scanner will not read UPC E bar codes UPC E Disable UPC E Enable DEFAULT UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E bar code...

Страница 101: ...13 data format Selecting this feature also changes the symbology ID to match those required for EAN 13 DEFAULT UPC E to EAN 13 Don t Expand UPC E to EAN 13 Expand Expand UPC E to UPC A Expands UPC E...

Страница 102: ...Number System Character Do not transmit UPC E Number System Character Transmit DEFAULT UPC E Minimum Read This feature specifies the minimum number of consecutive times a UPC E label must be decoded...

Страница 103: ...ble When disabled the scanner will not read EAN 13 JAN 13 bar codes EAN 13 Disable EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the check character along wi...

Страница 104: ...racter is the first character of the label EAN 13 Flag 1 Char Don t transmit EAN 13 Flag 1 Char Transmit DEFAULT EAN 13 ISBN Conversion This option enables disables conversion of EAN 13 JAN 13 Booklan...

Страница 105: ...ith 977 to ISSN labels DEFAULT ISSN Disable ISSN Enable EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as goo...

Страница 106: ...n disabled the scanner will not read EAN 8 JAN 8 bar codes EAN 8 Disable EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 bar...

Страница 107: ...T Expand EAN 8 to EAN 13 Disable Expand EAN 8 to EAN 13 Enable EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 Jan 8 label must be decoded before it is acce...

Страница 108: ...ture description UPC EAN Decoding Level Decoding Levels are used to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See De...

Страница 109: ...n Enable 5 digit price weight check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation DEFAULT Price Weight Che...

Страница 110: ...A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as good read DEFAULT UPC A Minimum Reads 1 UPC A Minimum Reads 2 UPC...

Страница 111: ...supple mentals P2 P5 NOTE DEFAULT Optional Add Ons Disable P2 Optional Add Ons Enable P2 DEFAULT Optional Add Ons Disable P5 Optional Add Ons Enable P5 If a UPC EAN base label and a an add on are bot...

Страница 112: ...dd on when an add on fragment has been seen and optional add ons are enabled Optional Add on Timer 10ms Optional Add on Timer 20ms Optional Add on Timer 30ms Optional Add on Timer 50ms Optional Add on...

Страница 113: ...s This feature specifies the minimum number of times a P2 add on must be read before it is marked as valid and then combined with a base label P2 Add Ons Minimum Reads 1 P2 Add Ons Minimum Reads 2 DEF...

Страница 114: ...feature specifies the minimum number of times a P5 add on must be read before it is marked as valid and then combined with a base label DEFAULT P5 Add Ons Minimum Reads 1 P5 Add Ons Minimum Reads 2 P5...

Страница 115: ...d the scanner will not read GS1 DataBar Omnidirectional bar codes DEFAULT GS1 DataBar Omnidirectional Disable GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Emulation When enab...

Страница 116: ...e minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read DEFAULT GS1 DataBar Omnidirectional Minimum Reads 1 GS1 DataBar Omnidirecti...

Страница 117: ...able When disabled the scanner will not read GS1 DataBar Expanded bar codes DEFAULT GS1 DataBar Expanded Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 128 Emulation When enabled GS1 Dat...

Страница 118: ...ecifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good read DEFAULT GS1 DataBar Expanded Minimum Reads 1 GS1 DataBar Expanded Minimu...

Страница 119: ...l on page 109 Length 1 is the minimum label length if in Variable Length on page 109 Mode or the first fixed length if in Fixed Length on page 109 Mode Length includes the bar code s data characters o...

Страница 120: ...to 74 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select GS1 DataBar Expanded Set Length 2...

Страница 121: ...sable When disabled the scanner will not read GS1 DataBar Limited bar codes DEFAULT GS1 DataBar Limited Disable GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataBa...

Страница 122: ...specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read DEFAULT GS1 DataBar Limited Minimum Reads 1 GS1 DataBar Limited Minimum...

Страница 123: ...ng Mode Product Reference Guide 113 Code 39 The following options apply to the Code 39 symbology Code 39 Enable Disable When disabled the scanner will not read Code 39 bar codes Code 39 Disable Code 3...

Страница 124: ...any check character in the label is treated as a data character DEFAULT Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calculate Std Check Code 39 Check Chara...

Страница 125: ...e data Code 39 Check Character Transmission Don t Send Code 39 Check Character Transmission Send DEFAULT Code 39 Start Stop Character Transmission Enable this option to enable disable transmission of...

Страница 126: ...e 39 116 Heron HD3130 Code 39 Full ASCII In Code 39 decoding this enables disables the translation of Code 39 charac ters to Code 39 full ASCII characters DEFAULT Code 39 Full ASCII Disable Code 39 Fu...

Страница 127: ...areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label Code 39 Quiet Zones Quiet Zone on one side Code 39 Quiet Zones Quiet Zones on two sides...

Страница 128: ...eads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read Code 39 Minimum Reads 1 Code 39 Minimum Reads 2 DEFAULT Code 39 M...

Страница 129: ...ry aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc tions Code 39 Decoding Level Disabled Code 39 Decodi...

Страница 130: ...th decoding or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different...

Страница 131: ...s not include start stop characters The length can be set from 0 to 50 characters See Set Length 1 on page 245 for more detailed programming instructions Select Code 39 Set Length 1 Setting To configu...

Страница 132: ...length can be set from 1 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select Code 39 L...

Страница 133: ...specifies the ratio between an intercharacter space and module for Code 39 labels Code 39 Interdigit Ratio Disable Code 39 Interdigit Ratio 1 Code 39 Interdigit Ratio 2 Code 39 Interdigit Ratio 3 DEFA...

Страница 134: ...39 124 Heron HD3130 Code 39 Interdigit Ratio continued CC3IR06 Code 39 Interdigit Ratio 6 CC3IR07 Code 39 Interdigit Ratio 7 CC3IR08 Code 39 Interdigit Ratio 8 CC3IR09 Code 39 Interdigit Ratio 9 CC3I...

Страница 135: ...the bar code parts will be assembled by the scanner s software and the data will be decoded if all bar code proofing requirements are met Code 39 Stitching Disable Code 39 Stitching Enable DEFAULT Cod...

Страница 136: ...e 123 Code 39 Stitching on page 125 Code 32 Check Character Transmission Enable this option to transmit the check character along with Code 32 bar code data DEFAULT Code 32 Check Character Transmissio...

Страница 137: ...ode 39 CIP Enable Disable Enables Disables ability of the scanner to decode Code 39 CIP labels DEFAULT Code 39 CIP Disable Code 39 CIP Enable Code 128 The following options apply to the Code 128 symbo...

Страница 138: ...shall be set to Code 39 and all Code 39 formatting control shall be applied to the label DEFAULT Code 128 to Code 39 Don t Expand Code 128 to Code 39 Expand Code 128 Check Character Transmission Enab...

Страница 139: ...4 DEFAULT Code 128 Function Character Transmission Don t Send Code 128 Function Character Transmission Send Code 128 Sub Code Change Transmission Enables disables the transmission of Sub Code exchange...

Страница 140: ...areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zones Quiet Zone on one side Code 128...

Страница 141: ...mum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read DEFAULT Code 128 Minimum Reads 1 Code 128 Minimum Reads 2 C...

Страница 142: ...ive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc tions Code 128 Decoding Level Disabled Code 128 Decoding Level...

Страница 143: ...le length decoding or fixed length decoding for the Code 128 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two d...

Страница 144: ...ngth can be set from 1 to 80 characters See Set Length 1 on page 245 for more detailed programming instructions Select Code 128 Set Length 1 Setting To configure this feature scan the ENTER EXIT bar c...

Страница 145: ...configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix D Key pad representing your desired character s End...

Страница 146: ...les disables the ability of the scanner to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data forma...

Страница 147: ...the I 2 of 5 symbology CAUTION When reading this symbology the settings for I 2 of 5 Length Control AND I 2 of 5 Check Character Calculation MUST be enabled to increase decoding safety I 2 of 5 Enabl...

Страница 148: ...Check Char Calc Disable I 2 of 5 Check Char Calc Check Standard Modulo 10 I 2 of 5 Check Char Calc Check German Parcel I 2 of 5 Check Char Calc Check DHL I 2 of 5 Check Char Calc Check Daimler Chrysle...

Страница 149: ...nsmission Enable this option to transmit the check character along with I 2 of 5 bar code data NOTE I 2 of 5 Check Character Transmission Don t Send I 2 of 5 Check Character Transmission Send DEFAULT...

Страница 150: ...nimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read I 2 of 5 Minimum Reads 1 I 2 of 5 Minimum Reads 2 DEFAUL...

Страница 151: ...to configure a bar code symbology decoder to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc t...

Страница 152: ...able length decoding or fixed length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two...

Страница 153: ...length can be set from 2 to 50 characters in increments of two See Set Length 1 on page 245 for more detailed programming instructions Select I 2 of 5 Length 1 Setting To configure this feature scan...

Страница 154: ...ructions Select I 2 of 5 Length 2 Setting To configure this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix D Key p...

Страница 155: ...IP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology Interleaved 2 of 5 CIP HR Enable Disable Enables Disables ability of scanner to decode Interleaved 2 of 5 CIP HR labels DEF...

Страница 156: ...r will not read Datalogic 2 of 5 bar codes DEFAULT Datalogic 2 of 5 Disable Datalogic 2 of 5 Enable Datalogic 2 of 5 Check Character Calculation This option enables disables calculation and verificati...

Страница 157: ...Character Transmission Don t Send Datalogic 2 of 5 Check Character Transmission Send DEFAULT Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic...

Страница 158: ...5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum...

Страница 159: ...e length can be set from 2 to 50 characters in increments of two See Set Length 1 on page 245 for more detailed programming instructions Select Datalogic 2 of 5 Length 1 Setting To configure this feat...

Страница 160: ...to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select Datalogic 2 of 5 Length 2 Setting...

Страница 161: ...o between intercharacter space and module for Datalogic 2 of 5 Datalogic 2 of 5 Interdigit Ratio Disable Datalogic 2 of 5 Interdigit Ratio 1 Datalogic 2 of 5 Interdigit Ratio 2 Datalogic 2 of 5 Interd...

Страница 162: ...ogic 2 of 5 Interdigit Maximum Ratio continued CD2IR06 Datalogic 2 of 5 Interdigit Ratio 6 CD2IR07 Datalogic 2 of 5 Interdigit Ratio 7 CD2IR08 Datalogic 2 of 5 Interdigit Ratio 8 CD2IR09 Datalogic 2 o...

Страница 163: ...dabar Check Character Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check characters in the label are treated...

Страница 164: ...on t Send Codabar Check Character Transmission Send DEFAULT This feature is valid only when Codabar Check Character Calculation is enabled Codabar Start Stop Character Transmission Enable this option...

Страница 165: ...Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar Check Character Set abcd tn e Codabar Check Character Set abcd abcd DEFAULT Codabar Start Stop Character Match When enabled this option req...

Страница 166: ...t the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label Codabar Quiet Zones Quiet Zone on one side Codabar Quiet Zones Quiet Zones on two sides Codabar...

Страница 167: ...nimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read DEFAULT Codabar Minimum Reads 1 Codabar Minimum Reads 2 Co...

Страница 168: ...ssive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc tions Codabar Decoding Level Disabled Codabar Decoding Level...

Страница 169: ...ble length decoding or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two d...

Страница 170: ...at least one data character The length can be set from 3 to 50 characters See Set Length 1 on page 245 for more detailed programming instructions Select Codabar Length 1 Setting To configure this fea...

Страница 171: ...ter The length can be set from 3 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select C...

Страница 172: ...he maximum ratio between an intercharacter space and module for Codabar labels Codabar Interdigit Ratio Disable Codabar Interdigit Ratio 1 Codabar Interdigit Ratio 2 Codabar Interdigit Ratio 3 DEFAULT...

Страница 173: ...Product Reference Guide 163 Codabar Interdigit Ratio continued CCBIR06 Codabar Interdigit Ratio 6 CCBIR07 Codabar Interdigit Ratio 7 CCBIR08 Codabar Interdigit Ratio 8 CCBIR09 Codabar Interdigit Rati...

Страница 174: ...r Enable Disable Enables Disables ability of scanner to decode ABC Codabar labels DEFAULT ABC Codabar Disable ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between...

Страница 175: ...e this feature scan the ENTER EXIT bar code above then the bar code at left followed by digits from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanni...

Страница 176: ...de Code 11 166 Heron HD3130 Code 11 The following options apply to the Code 11 symbology Code 11 Enable Disable When disabled the scanner will not read Code 11 bar codes DEFAULT Code 11 Disable Code 1...

Страница 177: ...lation Disable Code 11 Check Character Calculation Check C Code 11 Check Character Calculation Check K Code 11 Check Character Calculation Check C and K DEFAULT Code 11 Check Character Transmission Th...

Страница 178: ...eads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read Code 11 Minimum Reads 1 Code 11 Minimum Reads 2 DEFAULT Code 11 M...

Страница 179: ...minimum label length if in Variable Length on page 169 Mode or the first fixed length if in Fixed Length on page 169 Mode Length includes the bar code s check and data characters The length can be set...

Страница 180: ...racters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select Code 11 Length 2 Setting To configure this...

Страница 181: ...specifies the ratio between an intercharacter space and module for Code 11 labels Code 11 Interdigit Ratio Disable Code 11 Interdigit Ratio 1 Code 11 Interdigit Ratio 2 Code11 Interdigit Ratio 3 DEFA...

Страница 182: ...ode 11 172 Heron HD3130 Code 11 Interdigit Ratio cont CC1IR06 Code 11 Interdigit Ratio 6 CC1IR07 Code 11 Interdigit Ratio 7 CC1IR08 Code 11 Interdigit Ratio 8 CC1IR09 Code 11 Interdigit Ratio 9 CC1IR0...

Страница 183: ...ry aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc tions Codabar Decoding Level Disabled Codabar Decodi...

Страница 184: ...ner will not read Standard 2 of 5 bar codes DEFAULT Standard 2 of 5 Disable Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation This option enables disables calculation and verification...

Страница 185: ...Transmission Don t Send Standard 2 of 5 Check Character Transmission Send DEFAULT Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label...

Страница 186: ...5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum le...

Страница 187: ...aracters The length can be set from 1 to 50 characters See Set Length 1 on page 245 for more detailed programming instructions Select Standard 2 of 5 Length 1 Setting To configure this feature scan th...

Страница 188: ...o 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select Standard 2 of 5 Length 2 Setting To...

Страница 189: ...bility of scanner to decode Industrial 2 of 5 labels DEFAULT Industrial 2 of 5 Disable Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verificat...

Страница 190: ...aracter Transmission Enable DEFAULT Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology Variable Length...

Страница 191: ...only The length can be set from 1 to 50 characters See Set Length 1 on page 245 for more detailed programming instructions Select Industrial 2 of 5 Set Length 1 Setting To configure this feature scan...

Страница 192: ...cters The length can be set from 1 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select...

Страница 193: ...ture specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read DEFAULT Industrial 2 of 5 Minimum Reads 1 Industrial 2 of 5 Minimum...

Страница 194: ...les the ability of the scanner to decode IATA labels DEFAULT IATA Disable IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2 of 5 c...

Страница 195: ...enation of 2 labels DEFAULT ISBN 128 Concatenation Disable ISBN 128 Concatenation Enable ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic DEFAULT ISBT 128 Concat...

Страница 196: ...tion Mode ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec DEFAULT ISBT 128 Dynamic Concatenation Timeout 200 msec ISBT 128 Dynamic Concatenation Timeout...

Страница 197: ...NOTE DEFAULT ISBT 128 Force Concatenation Disable ISBT 128 Force Concatenation Enable This option is only valid when ISBT 128 Concatenation on page 185 is enabled see page 10 185 ISBT 128 Advanced Con...

Страница 198: ...FAULT MSI Disable MSI Enable MSI Check Character Calculation Enables Disables calculation and verification of an optional MSI check charac ter MSI Check Character Calculation Disable MSI Check Charact...

Страница 199: ...Character Transmission Enable DEFAULT MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology Variable Length For variable length decod...

Страница 200: ...can be set from 01 to 50 characters See Set Length 1 on page 245 for more detailed programming instructions Select MSI Set Length 1 Setting To configure this feature scan the ENTER EXIT bar code above...

Страница 201: ...s The length can be set from 1 to 50 characters A setting of 0 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select MSI...

Страница 202: ...mum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read MSI Minimum Reads 1 MSI Minimum Reads 2 MSI Minimum Reads 3 MSI...

Страница 203: ...r to be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc tions MSI Decoding Level Disable MSI Decod...

Страница 204: ...es Disables ability of scanner to decode Code 93 labels DEFAULT Code 93 Disable Code 93 Enable Code 93 Check Character Calculation Enables disables calculation and verification of an optional Code 93...

Страница 205: ...le Code 93 Check Character Transmission Enable DEFAULT Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology Variable Length...

Страница 206: ...r Exit Programming Mode Code 93 196 Heron HD3130 Fixed Length For fixed length decoding two different lengths may be set DEFAULT Code 93 Length Control Variable Length Code 93 Fixed Length CC9LC00 CC9...

Страница 207: ...The length can be set from 01 to 50 characters See Set Length 1 on page 245 for more detailed programming instructions Select Code 93 Set Length 1 Setting To configure this feature scan the ENTER EXIT...

Страница 208: ...length can be set from 1 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select Code 93 L...

Страница 209: ...nimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read DEFAULT Code 93 Minimum Reads 1 Code 93 Minimum Reads 2 Co...

Страница 210: ...essive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc tions Code 93 Decoding Level Disable Code 93 Decoding Level...

Страница 211: ...ching for Code 93 NOTE Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Quiet Zone on one side Code 93 Quiet Zones Quiet Zones on two sides Code 93 Quiet Zones Auto DEFAULT Code 93 Quiet Zones V...

Страница 212: ...F Enable Disable Enables Disables the ability of the scanner to decode Codablock F labels DEFAULT Codablock F Disable Codablock F Enable Codablock F EAN Enable Disable Enables Disables the Codablock F...

Страница 213: ...AIM compliant DEFAULT Codablock F Length Control This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology Variable Length For variable length decod...

Страница 214: ...length can be set from 003 to 255 characters See Set Length 1 on page 245 for more detailed programming instructions Select Codablock F Length 1 Setting To configure this feature scan the ENTER EXIT...

Страница 215: ...ers The length can be set from 003 to 255 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Selec...

Страница 216: ...es Disables ability of scanner to decode Code 4 labels DEFAULT Code 4 Disable Code 4 Enable Code 4 Check Character Transmission This feature enables disables transmission of an optional Code 4 check c...

Страница 217: ...f hexadecimal label data to dec imal label data Code 4 Hex to Decimal Conversion Disable Code 4 Hex to Decimal Conversion Enable DEFAULT Code 5 The following options apply to the Code 5 symbology Code...

Страница 218: ...k charac ter Code 5 Check Character Transmission Don t Send Code 5 Check Character Transmission Send DEFAULT Code 5 Hex to Decimal Conversion This feature enables disables the conversion of hexadecima...

Страница 219: ...e very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more programming instructions NOTE Code 4 and Code 5 Decoding Level Disabled Code...

Страница 220: ...Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read DEFAULT Code 4 or Code 5 Minimum Reads 1 Code 4 or Code...

Страница 221: ...t 2 of 5 Enable Disable Enables Disables ability of scanner to decode Follett 2 of 5 labels DEFAULT Follett 2 of 5 Disable Follett 2 of 5 Enable BC412 The following options apply to the BC412 symbolog...

Страница 222: ...treated as a data character DEFAULT BC412 Check Character Calculation Don t Calculate BC412 Check Character Calculation Calculate Check Charac ter BC412 Minimum Reads This feature specifies the minimu...

Страница 223: ...be very aggressive to very conservative depending on a particular customer s needs See Decoding Levels on page 245 for more detailed programming instruc tions BC412 Decoding Level Disable BC412 Decodi...

Страница 224: ...el length if in Variable Length on page 214 Mode or the first fixed length if in Fixed Length on page 214 Mode Length includes the bar code s data characters only The length can be set from 01 to 50 c...

Страница 225: ...s The length can be set from 1 to 50 characters A setting of 00 specifies to ignore this length only one fixed length See Set Length 2 on page 247 for more detailed programming instructions Select BC4...

Страница 226: ...Enter Exit Programming Mode BC412 216 Heron HD3130 NOTES...

Страница 227: ...Interval on page 226 Intercharacter Delay on page 227 Intercode Delay on page 228 DATA FORMAT on page 229 Data Editing on page 229 Global Prefix Suffix on page 230 Global AIM ID on page 231 Label ID o...

Страница 228: ...type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits...

Страница 229: ...SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last c...

Страница 230: ...data is not recognized when the option Stop Bits on page 22 has been set as 7 Data Bits 1 Determine the desired character or value 2 Use the ASCII Chart on page 287 on the inside back cover of this ma...

Страница 231: ...d character value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode 4 Scan the bar code SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from t...

Страница 232: ...Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character NO...

Страница 233: ...in Appendix D Keypad that represent the number which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character...

Страница 234: ...page 33 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT DISABLE CHARACTER SETTING on page 33 5 Scan the appropriate two alphanumeric characters f...

Страница 235: ...he desired character value 3 Go to page 34 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT ENABLE CHARACTER SETTING on page 34 5 Scan the appropr...

Страница 236: ...the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If...

Страница 237: ...ELAY SETTING on page 43 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication a...

Страница 238: ...esent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to...

Страница 239: ...s function is used to identify and display the common label identifier for its symbology When enabled this ID code will be transmitted before the scanned bar code data OR Bar Code Data NOTE Additional...

Страница 240: ...ING MODE bar code then scan the SET GLOBAL PREFIX bar code 3 Reference the ASCII Chart on page 287 on the inside back cover of this man ual to find the hex value assigned to the desired character The...

Страница 241: ...ws A close brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHAR SYMBOLOGY CHAR UPC EAN Ea a...

Страница 242: ...Label ID Pre loaded Sets The following table lists the pre loaded label ID sets for the USA and Europe Table 12 Label ID Pre loaded Sets Symbology USA Label ID set EU Label ID set ASCII character Hex...

Страница 243: ...60000 Industrial 2 of 5 W 570000 W 570000 Interleaved 2 of 5 CIP HR e 650000 e 650000 ISBN I 490000 400000 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI 400000 Z 5A0000 S25 s 730000 P 500000 UP...

Страница 244: ...SCII Chart on page 287 on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Label ID...

Страница 245: ...n starting on page 54 GS1 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII table inside back co...

Страница 246: ...it would look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were con verted to 2 characters Nothing is done with the last two...

Страница 247: ...T LABEL GONE TIMEOUT SETTING on page 83 5 Scan the appropriate three alpha numeric characters from the keypad in Appendix D Keypad representing the duration which was determined in the steps above You...

Страница 248: ...OOD READ RAISING TIME on page 77 or RBG GOOD READ FALLING TIME on page 78 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the...

Страница 249: ...8 and scan the bar code SELECT RGB GOOD READ HOLDING TIME 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above NOT...

Страница 250: ...o to page 79 and scan the bar code SELECT RGB AUTO DELAY TIME 5 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the duration which was determined in the steps above...

Страница 251: ...multi ple reads of the same label while in this mode Trigger Pulse Multiple When the trigger is pulled continuous scanning is acti vated until Scanning Active Time has elapsed or the trigger has been...

Страница 252: ...present the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code...

Страница 253: ...ypad in Appendix D Keypad rep resenting the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last cha...

Страница 254: ...ppendix D Keypad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character NOTE If you make a mistake before the last character s...

Страница 255: ...tive setting increase the decoding level to be more aggressive If the majority of labels are very good quality labels or there is a need to decrease the possibility of a decoder error lower the decodi...

Страница 256: ...string You can then start again at the beginning 5 Scan the ENTER EXIT PROGRAMMING MODE bar code to exit Programming Mode This completes the procedure See the table below for examples of how to set t...

Страница 257: ...Select Length 2 Setting for the symbology being set 4 Scan the appropriate two digits from the keypad in Appendix D Keypad that represent the length setting which was determined in the steps above You...

Страница 258: ...References 248 Heron HD3130 NOTES...

Страница 259: ...perating changing colors current 5V 300 mA Max Scan Rate 270 scans sec Reading Indicators Side and Top Illumination Good Read Spot Beep or Jingle Optical Features Sensor CCD solid state 2500 pixels Il...

Страница 260: ...Features Weight without cable approx 150 g 5 3 oz Cable Length Refer to www datalogic com Decode Capability UPC EAN P2 P5 add ons ISBN ISSN GTIN add on 2 5 Codabar ABC Codabar Interleaved 2 5 Code 93...

Страница 261: ...h the host is completed Imager beeps four times at highest frequency and vol ume upon power up Power up Good Read Upper green LED comes on for programmed time default LED behavior for this indication...

Страница 262: ...N A Scanner sounds one high fre quency beep and 4 low fre quency beeps followed by reset beeps Label Program ming Mode Can cel Item Entry Cancel label has been scanned N A Scanner sounds two times at...

Страница 263: ...Selftest and has entered FRU Field Replaceable Unit isolation mode If the scanner is reset the sequence will be repeated The fol lowing table describes the LED flashes beep codes associated with an er...

Страница 264: ...nal descriptions in Table 25 apply to the connector on the scanner and are for reference only Table 25 Standard Cable Pinouts Scanner Side Pin RS 232 USB Keyboard Wedge 1 RTS out 2 D CLKIN KBD side 3...

Страница 265: ...Stand Dimensions Product Reference Guide 255 Stand Dimensions...

Страница 266: ...Technical Specifications 256 Heron HD3130 Stand Base Plate Template SCREW HERE SCREW HERE...

Страница 267: ...ming bar codes for each parameter A column has also been pro vided for recording of your preferred default settings for these same configu rable features Table 26 Standard Defaults Parameter Default Y...

Страница 268: ...rd Send Control Characters Disable 41 Wedge Quiet Interval 100ms 42 Intercharacter Delay No Delay 43 Intercode Delay 100 ms 44 USB Keyboard Speed 1 ms 45 USB OEM USB OEM Device Usage Handheld Scanner...

Страница 269: ...able RGB LED Enable 76 Good Read LED Color Green 77 RGB Good Read Raising Time 00 77 RGB Good Read Falling Time 14 78 RGB Good Read Holding Time 14 78 RGB Auto Delay 04 79 SCANNING FEATURES Scan Mode...

Страница 270: ...PC E Number System Character Transmission Transmit 92 UPC E Minimum Read 2 92 EAN 13 EAN 13 Enable Disable Enable 93 EAN 13 Check Character Transmis sion Send 93 EAN 13 Flag 1 Character Transmit 94 EA...

Страница 271: ...5 GS1 DataBar Omnidirectional Min imum Reads 1 106 GS1 DataBar Expanded GS1 DataBar Expanded Enable Disable Disable 107 GS1 DataBar Expanded GS1 128 Emulation Disable 107 GS1 DataBar Expanded Minimum...

Страница 272: ...Variable 120 Code 39 Set Length 1 2 121 Code 39 Set Length 2 50 122 Code 39 Interdigit Ratio 4 123 Code 32 Code 32 Enable Disable Disable 125 Code 32 Check Character Trans mission Don t Send 126 Code...

Страница 273: ...oding Level 3 141 I 2 of 5 Length Control Variable 142 I 2 of 5 Set Length 1 6 143 I 2 of 5 Set Length 2 50 144 Interleaved 2 of 5 CIP Interleaved 2 of 5 CIP HR Enable Disable Disable 145 Datalogic 2...

Страница 274: ...coding Level 3 158 Codabar Length Control Variable 159 Codabar Set Length 1 3 160 Codabar Set Length 2 50 161 Codabar Interdigit Ratio 4 162 ABC Codabar ABC Codabar Enable Disable Disable 164 ABC Coda...

Страница 275: ...ength 1 8 177 Standard 2 of 5 Set Length 2 50 178 Industrial 2 of 5 Industrial 2 of 5 Enable Disable Disable 179 Industrial 2 of 5 Check Character Calculation Disable 179 Industrial 2 of 5 Check Chara...

Страница 276: ...Reads 4 Reads 192 MSI Decoding Level Level 3 193 Code 93 Code 93 Enable Disable Disable 194 Code 93 Check Character Calcula tion Disable 194 Code 93 Check Character Trans mission Enable 195 Code 93 Le...

Страница 277: ...208 Code 5 Hex to Decimal Conversion Enable 208 Code 4 and Code 5 Common Configuration Items Code 4 and 5 Decoding Level 3 209 Code 4 and Code 5 Minimum Reads 1 210 Follett 2 of 5 Follett 2 of 5 Enab...

Страница 278: ...rol RTS CTS Transmission Label ID Code Prefix GS1 128 AIM ID Disable UPCE Label ID Character s C EAN 8 Label ID Character s B EAN 13 Label ID Character s A Code ISBN Label ID Character s A Code 39 Lab...

Страница 279: ...ransmission Label ID Code Prefix GS1 128 AIM ID Disable UPCA Label ID Character s C UPCE Label ID Character s D EAN 8 Label ID Character s A EAN 13 Label ID Character s B Code ISBN Label ID Character...

Страница 280: ...haracter s K EAN8 GS1 128 Label ID Character s EAN13 P2 Label ID Character s L EAN13 P5 Label ID Character s M EAN13 GS1 128 Label ID Character s GS1 DataBar 14 Omnidirectional Label ID Character s u...

Страница 281: ...ference Guide 271 Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types 1D Bar Codes 0 12345 67890 5 UPC A 3 456789 012340 EAN 13 Code...

Страница 282: ...Code 128 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 12345678901231 Interleaved 2 of 5 Sample Bar Codes 272 Heron HD3130 Code 32 Codabar Code 93 Code 11...

Страница 283: ...taBar RSS on page 273 GS1 DataBar 14 10293847560192837465019283746029478450366523 GS1 DataBar Expanded Stacked 1234890hjio9900mnb GS1 DataBar Expanded 08672345650916 GS1 DataBar Limited 55432198673467...

Страница 284: ...Sample Bar Codes 274 Heron HD3130 NOTES...

Страница 285: ...Product Reference Guide 275 Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4...

Страница 286: ...Keypad 276 Heron HD3130 Keypad continued 5 6 7 8 9 A B...

Страница 287: ...Product Reference Guide 277 Keypad continued C D E F...

Страница 288: ...Keypad 278 Heron HD3130 NOTES...

Страница 289: ...aracter Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII tab...

Страница 290: ...X C S C EOT C S D ENQ C S E ACK C S F BEL C S G BS HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C...

Страница 291: ...F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x 9x Ax NBSP Bx Cx...

Страница 292: ...101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5...

Страница 293: ...0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 0142 A 0143 9x A 0144 A 0145 A 0146 A 0147 A 0148 A 0149 A 0150 A 0151 A 0152 A 0153 A 0154 A 0155 A 0156 A 0157 A 0158 A 0159 Ax A 0160 A 0161 A 0162...

Страница 294: ...284 Heron HD3130 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy components of Microsoft Windows in English and some other Wes...

Страница 295: ...or Codes 253 Errors 253 G Good Read Beeper 65 Pitch 73 Volume 74 Good Read Beeper 65 Good Read Beeper Pitch 73 Good Read Beeper Volume 74 H Handheld Scanner 48 I Indications 251 K keyboard support 36...

Страница 296: ...9 271 interleaved 2 of 5 272 Scancode Tables 279 select digits characters 275 Serial Output 254 Standard Cable Pinouts 254 Suffix 50 230 Symbologies 217 symbology types 271 T Table Top Scanner 48 U UP...

Страница 297: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Страница 298: ...ed Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 54...

Отзывы: